Terminology Change Set Exchange
1.0.0-ballot - STU1 Ballot International flag

This page is part of the Terminology Change Set Exchange (v1.0.0-ballot: STU1 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. . For a full list of available versions, see the Directory of published versions

: LOINC 2.77 Attachments Change Set for targetted redistribution - TTL Representation

Page standards status: Informative

Raw ttl | Download

@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <https://loinc.org/rdf/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:CodeSystem ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "loinc277attachmentsChangeSet"] ; # 
  fhir:meta [
    ( fhir:profile [
fhir:v "http://hl7.org/fhir/uv/termchangeset/StructureDefinition/loinc-changeset-profile"^^xsd:anyURI ;
fhir:link <http://hl7.org/fhir/uv/termchangeset/StructureDefinition/loinc-changeset-profile>     ] )
  ] ; # 
  fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: CodeSystem loinc277attachmentsChangeSet</b></p><a name=\"loinc277attachmentsChangeSet\"> </a><a name=\"hcloinc277attachmentsChangeSet\"> </a><a name=\"loinc277attachmentsChangeSet-en-US\"> </a><p><b>Properties</b></p><p><b>This code system defines the following properties for its concepts</b></p><table class=\"grid\"><tr><td><b>Name</b></td><td><b>Code</b></td><td><b>URI</b></td><td><b>Type</b></td><td><b>Description</b></td></tr><tr><td>STATUS</td><td>STATUS</td><td>http://loinc.org/property/STATUS</td><td>string</td><td>Status of the term. Within LOINC, codes with STATUS=DEPRECATED are considered inactive. Current values: ACTIVE, TRIAL, DISCOURAGED, and DEPRECATED</td></tr><tr><td>COMPONENT</td><td>COMPONENT</td><td>http://loinc.org/property/COMPONENT</td><td>Coding</td><td>First major axis-component or analyte: Analyte Name, Analyte sub-class, Challenge</td></tr><tr><td>PROPERTY</td><td>PROPERTY</td><td>http://loinc.org/property/PROPERTY</td><td>Coding</td><td>Second major axis-property observed: Kind of Property (also called kind of quantity)</td></tr><tr><td>TIME_ASPCT</td><td>TIME_ASPCT</td><td>http://loinc.org/property/TIME_ASPCT</td><td>Coding</td><td>Third major axis-timing of the measurement: Time Aspect (Point or moment in time vs. time interval)</td></tr><tr><td>SYSTEM</td><td>SYSTEM</td><td>http://loinc.org/property/SYSTEM</td><td>Coding</td><td>Fourth major axis-type of specimen or system: System (Sample) Type</td></tr><tr><td>SCALE_TYP</td><td>SCALE_TYP</td><td>http://loinc.org/property/SCALE_TYP</td><td>Coding</td><td>Fifth major axis-scale of measurement: Type of Scale</td></tr><tr><td>METHOD_TYP</td><td>METHOD_TYP</td><td>http://loinc.org/property/METHOD_TYP</td><td>Coding</td><td>Sixth major axis-method of measurement: Type of Method</td></tr><tr><td>CLASS</td><td>CLASS</td><td>http://loinc.org/property/CLASS</td><td>Coding</td><td>An arbitrary classification of terms for grouping related observations together</td></tr><tr><td>VersionLastChanged</td><td>VersionLastChanged</td><td>http://loinc.org/property/VersionLastChanged</td><td>string</td><td>The LOINC version number in which the record has last changed. For new records, this field contains the same value as the VersionFirstReleased property.</td></tr><tr><td>CLASSTYPE</td><td>CLASSTYPE</td><td>http://loinc.org/property/CLASSTYPE</td><td>string</td><td>1=Laboratory class; 2=Clinical class; 3=Claims attachments; 4=Surveys</td></tr><tr><td>ORDER_OBS</td><td>ORDER_OBS</td><td>http://loinc.org/property/ORDER_OBS</td><td>string</td><td>Provides users with an idea of the intended use of the term by categorizing it as an order only, observation only, or both</td></tr><tr><td>HL7_ATTACHMENT_STRUCTURE</td><td>HL7_ATTACHMENT_STRUCTURE</td><td>http://loinc.org/property/HL7_ATTACHMENT_STRUCTURE</td><td>string</td><td>This property is populated in collaboration with the HL7 Payer-Provider Exchange (PIE) Work Group (previously called Attachments Work Group) as described in the HL7 Attachment Specification: Supplement to Consolidated CDA Templated Guide.</td></tr><tr><td>VersionFirstReleased</td><td>VersionFirstReleased</td><td>http://loinc.org/property/VersionFirstReleased</td><td>string</td><td>This is the LOINC version number in which this LOINC term was first published.</td></tr><tr><td>ValidHL7AttachmentRequest</td><td>ValidHL7AttachmentRequest</td><td>http://loinc.org/property/ValidHL7AttachmentRequest</td><td>string</td><td>A value of Y in this field indicates that this LOINC code can be sent by a payer as part of an HL7 Attachment request for additional information.</td></tr></table><p><b>Filters</b></p><table class=\"grid\"><tr><td><b>Code</b></td><td><b>Description</b></td><td><b>Op</b></td><td><b>Value</b></td></tr><tr><td>parent</td><td>Allows for the selection of a set of codes based on their appearance in the LOINC Multiaxial Hierarchy. Parent selects immediate parent only. For example, the code '79190-5' has the parent 'LP379670-5'</td><td>= </td><td>A Part code</td></tr><tr><td>child</td><td>Allows for the selection of a set of codes based on their appearance in the LOINC Multiaxial Hierarchy. Child selects immediate children only. For example, the code 'LP379670-5' has the child '79190-5'. Only LOINC Parts have children; LOINC codes do not have any children because they are leaf nodes.</td><td>= </td><td>A comma separated list of Part or LOINC codes</td></tr><tr><td>copyright</td><td>Allows for the inclusion or exclusion of LOINC codes that include 3rd party copyright notices. LOINC = only codes with a sole copyright by Regenstrief. 3rdParty = only codes with a 3rd party copyright in addition to the one from Regenstrief</td><td>= </td><td>LOINC | 3rdParty</td></tr></table><p><b>Concepts</b></p><p>This case-insensitive code system <code>http://ikm.dev/changesets/CodeSystem/loinc277attachmentsChangeSet</code> provides <b>a fragment</b> that includes following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td style=\"white-space:nowrap\">103595-5<a name=\"loinc277attachmentsChangeSet-103595-5\"> </a></td><td>Cert Med Neces</td><td>Certificate of Medical Necessity</td></tr><tr><td style=\"white-space:nowrap\">103596-3<a name=\"loinc277attachmentsChangeSet-103596-3\"> </a></td><td>DME proof of delivery</td><td>Durable medical equipment proof of delivery receipt</td></tr><tr><td style=\"white-space:nowrap\">103597-1<a name=\"loinc277attachmentsChangeSet-103597-1\"> </a></td><td>Pain magt form/template</td><td>Pain management form or template</td></tr></table></div>"
  ] ; # 
  fhir:url [ fhir:v "http://ikm.dev/changesets/CodeSystem/loinc277attachmentsChangeSet"^^xsd:anyURI] ; # 
  fhir:identifier ( [
fhir:system [ fhir:v "urn:ietf:rfc:3986"^^xsd:anyURI ] ;
fhir:value [ fhir:v "urn:oid:2.16.840.1.113883.6.1" ]
  ] ) ; # 
  fhir:version [ fhir:v "1.0.0-ballot"] ; # 
  fhir:name [ fhir:v "LOINC_277_Attachments_ChangeSet"] ; # 
  fhir:title [ fhir:v "LOINC 2.77 Attachments Change Set for targetted redistribution"] ; # 
  fhir:status [ fhir:v "active"] ; # 
  fhir:experimental [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:date [ fhir:v "2024-08-14T14:53:44+00:00"^^xsd:dateTime] ; # 
  fhir:publisher [ fhir:v "HL7 International / Terminology Infrastructure"] ; # 
  fhir:contact ( [
    ( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "http://www.hl7.org/Special/committees/Vocab" ]     ] )
  ] ) ; # 
  fhir:description [ fhir:v "Example of LOINC Change Set including all new Document Attachments defined in LOINC 2.77 for pre-adoption on 2.76 implementations"] ; # 
  fhir:jurisdiction ( [
    ( fhir:coding [
fhir:system [ fhir:v "http://unstats.un.org/unsd/methods/m49/m49.htm"^^xsd:anyURI ] ;
fhir:code [ fhir:v "001" ]     ] )
  ] ) ; # 
  fhir:copyright [ fhir:v "This material contains content from LOINC (http://loinc.org). LOINC is copyright ©1995-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc."] ; # 
  fhir:caseSensitive [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:compositional [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:versionNeeded [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:content [ fhir:v "fragment"] ; # 
  fhir:filter ( [
fhir:code [ fhir:v "parent" ] ;
fhir:description [ fhir:v "Allows for the selection of a set of codes based on their appearance in the LOINC Multiaxial Hierarchy. Parent selects immediate parent only. For example, the code '79190-5' has the parent 'LP379670-5'" ] ;
    ( fhir:operator [ fhir:v "=" ] ) ;
fhir:value [ fhir:v "A Part code" ]
  ] [
fhir:code [ fhir:v "child" ] ;
fhir:description [ fhir:v "Allows for the selection of a set of codes based on their appearance in the LOINC Multiaxial Hierarchy. Child selects immediate children only. For example, the code 'LP379670-5' has the child '79190-5'. Only LOINC Parts have children; LOINC codes do not have any children because they are leaf nodes." ] ;
    ( fhir:operator [ fhir:v "=" ] ) ;
fhir:value [ fhir:v "A comma separated list of Part or LOINC codes" ]
  ] [
fhir:code [ fhir:v "copyright" ] ;
fhir:description [ fhir:v "Allows for the inclusion or exclusion of LOINC codes that include 3rd party copyright notices. LOINC = only codes with a sole copyright by Regenstrief. 3rdParty = only codes with a 3rd party copyright in addition to the one from Regenstrief" ] ;
    ( fhir:operator [ fhir:v "=" ] ) ;
fhir:value [ fhir:v "LOINC | 3rdParty" ]
  ] ) ; # 
  fhir:property ( [
fhir:code [ fhir:v "STATUS" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/STATUS"^^xsd:anyURI ] ;
fhir:description [ fhir:v "Status of the term. Within LOINC, codes with STATUS=DEPRECATED are considered inactive. Current values: ACTIVE, TRIAL, DISCOURAGED, and DEPRECATED" ] ;
fhir:type [ fhir:v "string" ]
  ] [
fhir:code [ fhir:v "COMPONENT" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/COMPONENT"^^xsd:anyURI ] ;
fhir:description [ fhir:v "First major axis-component or analyte: Analyte Name, Analyte sub-class, Challenge" ] ;
fhir:type [ fhir:v "Coding" ]
  ] [
fhir:code [ fhir:v "PROPERTY" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/PROPERTY"^^xsd:anyURI ] ;
fhir:description [ fhir:v "Second major axis-property observed: Kind of Property (also called kind of quantity)" ] ;
fhir:type [ fhir:v "Coding" ]
  ] [
fhir:code [ fhir:v "TIME_ASPCT" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/TIME_ASPCT"^^xsd:anyURI ] ;
fhir:description [ fhir:v "Third major axis-timing of the measurement: Time Aspect (Point or moment in time vs. time interval)" ] ;
fhir:type [ fhir:v "Coding" ]
  ] [
fhir:code [ fhir:v "SYSTEM" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/SYSTEM"^^xsd:anyURI ] ;
fhir:description [ fhir:v "Fourth major axis-type of specimen or system: System (Sample) Type" ] ;
fhir:type [ fhir:v "Coding" ]
  ] [
fhir:code [ fhir:v "SCALE_TYP" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/SCALE_TYP"^^xsd:anyURI ] ;
fhir:description [ fhir:v "Fifth major axis-scale of measurement: Type of Scale" ] ;
fhir:type [ fhir:v "Coding" ]
  ] [
fhir:code [ fhir:v "METHOD_TYP" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/METHOD_TYP"^^xsd:anyURI ] ;
fhir:description [ fhir:v "Sixth major axis-method of measurement: Type of Method" ] ;
fhir:type [ fhir:v "Coding" ]
  ] [
fhir:code [ fhir:v "CLASS" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/CLASS"^^xsd:anyURI ] ;
fhir:description [ fhir:v "An arbitrary classification of terms for grouping related observations together" ] ;
fhir:type [ fhir:v "Coding" ]
  ] [
fhir:code [ fhir:v "VersionLastChanged" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/VersionLastChanged"^^xsd:anyURI ] ;
fhir:description [ fhir:v "The LOINC version number in which the record has last changed. For new records, this field contains the same value as the VersionFirstReleased property." ] ;
fhir:type [ fhir:v "string" ]
  ] [
fhir:code [ fhir:v "CLASSTYPE" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/CLASSTYPE"^^xsd:anyURI ] ;
fhir:description [ fhir:v "1=Laboratory class; 2=Clinical class; 3=Claims attachments; 4=Surveys" ] ;
fhir:type [ fhir:v "string" ]
  ] [
fhir:code [ fhir:v "ORDER_OBS" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/ORDER_OBS"^^xsd:anyURI ] ;
fhir:description [ fhir:v "Provides users with an idea of the intended use of the term by categorizing it as an order only, observation only, or both" ] ;
fhir:type [ fhir:v "string" ]
  ] [
fhir:code [ fhir:v "HL7_ATTACHMENT_STRUCTURE" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/HL7_ATTACHMENT_STRUCTURE"^^xsd:anyURI ] ;
fhir:description [ fhir:v "This property is populated in collaboration with the HL7 Payer-Provider Exchange (PIE) Work Group (previously called Attachments Work Group) as described in the HL7 Attachment Specification: Supplement to Consolidated CDA Templated Guide." ] ;
fhir:type [ fhir:v "string" ]
  ] [
fhir:code [ fhir:v "VersionFirstReleased" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/VersionFirstReleased"^^xsd:anyURI ] ;
fhir:description [ fhir:v "This is the LOINC version number in which this LOINC term was first published." ] ;
fhir:type [ fhir:v "string" ]
  ] [
fhir:code [ fhir:v "ValidHL7AttachmentRequest" ] ;
fhir:uri [ fhir:v "http://loinc.org/property/ValidHL7AttachmentRequest"^^xsd:anyURI ] ;
fhir:description [ fhir:v "A value of Y in this field indicates that this LOINC code can be sent by a payer as part of an HL7 Attachment request for additional information." ] ;
fhir:type [ fhir:v "string" ]
  ] ) ; # 
  fhir:concept ( [
fhir:id [ fhir:v "1c8f2f61-9160-46c7-9664-80ae4a5a94c3" ] ;
fhir:code [ fhir:v "103595-5" ] ;
fhir:display [ fhir:v "Cert Med Neces" ] ;
fhir:definition [ fhir:v "Certificate of Medical Necessity" ] ;
    ( fhir:property [
fhir:code [ fhir:v "CLASS" ] ;
fhir:value [
a fhir:Coding, loinc:LP32888-7 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP32888-7" ] ;
fhir:display [ fhir:v "Doc" ]       ]     ] [
fhir:code [ fhir:v "VersionFirstReleased" ] ;
fhir:value [ fhir:v "2.77" ]     ] [
fhir:code [ fhir:v "STATUS" ] ;
fhir:value [ fhir:v "ACTIVE" ]     ] [
fhir:code [ fhir:v "CLASSTYPE" ] ;
fhir:value [ fhir:v "3" ]     ] [
fhir:code [ fhir:v "ORDER_OBS" ] ;
fhir:value [ fhir:v "Both" ]     ] [
fhir:code [ fhir:v "HL7_ATTACHMENT_STRUCTURE" ] ;
fhir:value [ fhir:v "No IG exists" ]     ] [
fhir:code [ fhir:v "ValidHL7AttachmentRequest" ] ;
fhir:value [ fhir:v "Y" ]     ] [
fhir:code [ fhir:v "VersionLastChanged" ] ;
fhir:value [ fhir:v "2.77" ]     ] [
fhir:code [ fhir:v "COMPONENT" ] ;
fhir:value [
a fhir:Coding, loinc:LP437323-1 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP437323-1" ] ;
fhir:display [ fhir:v "Certificate of medical necessity" ]       ]     ] [
fhir:code [ fhir:v "PROPERTY" ] ;
fhir:value [
a fhir:Coding, loinc:LP6813-2 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP6813-2" ] ;
fhir:display [ fhir:v "Find" ]       ]     ] [
fhir:code [ fhir:v "TIME_ASPCT" ] ;
fhir:value [
a fhir:Coding, loinc:LP6960-1 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP6960-1" ] ;
fhir:display [ fhir:v "Pt" ]       ]     ] [
fhir:code [ fhir:v "SYSTEM" ] ;
fhir:value [
a fhir:Coding, loinc:LP310005-6 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP310005-6" ] ;
fhir:display [ fhir:v "^Patient" ]       ]     ] [
fhir:code [ fhir:v "SCALE_TYP" ] ;
fhir:value [
a fhir:Coding, loinc:LP32888-7 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP32888-7" ] ;
fhir:display [ fhir:v "Doc" ]       ]     ] )
  ] [
fhir:id [ fhir:v "0ff172eb-d17d-4146-9581-ad45e4e62f0b" ] ;
fhir:code [ fhir:v "103596-3" ] ;
fhir:display [ fhir:v "DME proof of delivery" ] ;
fhir:definition [ fhir:v "Durable medical equipment proof of delivery receipt" ] ;
    ( fhir:property [
fhir:code [ fhir:v "CLASS" ] ;
fhir:value [
a fhir:Coding, loinc:LP32888-7 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP32888-7" ] ;
fhir:display [ fhir:v "Doc" ]       ]     ] [
fhir:code [ fhir:v "VersionFirstReleased" ] ;
fhir:value [ fhir:v "2.77" ]     ] [
fhir:code [ fhir:v "STATUS" ] ;
fhir:value [ fhir:v "ACTIVE" ]     ] [
fhir:code [ fhir:v "CLASSTYPE" ] ;
fhir:value [ fhir:v "3" ]     ] [
fhir:code [ fhir:v "ORDER_OBS" ] ;
fhir:value [ fhir:v "Observation" ]     ] [
fhir:code [ fhir:v "HL7_ATTACHMENT_STRUCTURE" ] ;
fhir:value [ fhir:v "No IG exists" ]     ] [
fhir:code [ fhir:v "ValidHL7AttachmentRequest" ] ;
fhir:value [ fhir:v "Y" ]     ] [
fhir:code [ fhir:v "VersionLastChanged" ] ;
fhir:value [ fhir:v "2.77" ]     ] [
fhir:code [ fhir:v "COMPONENT" ] ;
fhir:value [
a fhir:Coding, loinc:LP437553-3 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP437553-3" ] ;
fhir:display [ fhir:v "Durable medical equipment proof of delivery receipt" ]       ]     ] [
fhir:code [ fhir:v "PROPERTY" ] ;
fhir:value [
a fhir:Coding, loinc:LP6813-2 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP6813-2" ] ;
fhir:display [ fhir:v "Find" ]       ]     ] [
fhir:code [ fhir:v "TIME_ASPCT" ] ;
fhir:value [
a fhir:Coding, loinc:LP6960-1 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP6960-1" ] ;
fhir:display [ fhir:v "Pt" ]       ]     ] [
fhir:code [ fhir:v "SYSTEM" ] ;
fhir:value [
a fhir:Coding, loinc:LP310005-6 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP310005-6" ] ;
fhir:display [ fhir:v "^Patient" ]       ]     ] [
fhir:code [ fhir:v "SCALE_TYP" ] ;
fhir:value [
a fhir:Coding, loinc:LP32888-7 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP32888-7" ] ;
fhir:display [ fhir:v "Doc" ]       ]     ] )
  ] [
fhir:id [ fhir:v "9ce55d17-eee1-412d-9ebd-8ef36c896f8b" ] ;
fhir:code [ fhir:v "103597-1" ] ;
fhir:display [ fhir:v "Pain magt form/template" ] ;
fhir:definition [ fhir:v "Pain management form or template" ] ;
    ( fhir:property [
fhir:code [ fhir:v "CLASS" ] ;
fhir:value [
a fhir:Coding, loinc:LP32888-7 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP32888-7" ] ;
fhir:display [ fhir:v "Doc" ]       ]     ] [
fhir:code [ fhir:v "VersionFirstReleased" ] ;
fhir:value [ fhir:v "2.77" ]     ] [
fhir:code [ fhir:v "STATUS" ] ;
fhir:value [ fhir:v "ACTIVE" ]     ] [
fhir:code [ fhir:v "CLASSTYPE" ] ;
fhir:value [ fhir:v "3" ]     ] [
fhir:code [ fhir:v "ORDER_OBS" ] ;
fhir:value [ fhir:v "Observation" ]     ] [
fhir:code [ fhir:v "HL7_ATTACHMENT_STRUCTURE" ] ;
fhir:value [ fhir:v "No IG exists" ]     ] [
fhir:code [ fhir:v "ValidHL7AttachmentRequest" ] ;
fhir:value [ fhir:v "Y" ]     ] [
fhir:code [ fhir:v "VersionLastChanged" ] ;
fhir:value [ fhir:v "2.77" ]     ] [
fhir:code [ fhir:v "COMPONENT" ] ;
fhir:value [
a fhir:Coding, loinc:LP437336-3 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP437336-3" ] ;
fhir:display [ fhir:v "Pain management form or template" ]       ]     ] [
fhir:code [ fhir:v "PROPERTY" ] ;
fhir:value [
a fhir:Coding, loinc:LP6813-2 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP6813-2" ] ;
fhir:display [ fhir:v "Find" ]       ]     ] [
fhir:code [ fhir:v "TIME_ASPCT" ] ;
fhir:value [
a fhir:Coding, loinc:LP6960-1 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP6960-1" ] ;
fhir:display [ fhir:v "Pt" ]       ]     ] [
fhir:code [ fhir:v "SYSTEM" ] ;
fhir:value [
a fhir:Coding, loinc:LP310005-6 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP310005-6" ] ;
fhir:display [ fhir:v "^Patient" ]       ]     ] [
fhir:code [ fhir:v "SCALE_TYP" ] ;
fhir:value [
a fhir:Coding, loinc:LP32888-7 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "LP32888-7" ] ;
fhir:display [ fhir:v "Doc" ]       ]     ] )
  ] ) . #