This page is part of the CodeX™ Radiation Therapy (v1.0.0: STU 1) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-course-summary | Version: 1.0.0 | |||
Draft as of 2023-07-28 | Computable Name: RadiotherapyCourseSummary |
A summary of the treatment progress in a radiotherapy course. Whenever new contributions in the scope of the same course are delivered, this resource is updated (no new resource created).
This profile is used to capture a course of radiotherapy delivered to a patient. An overview of radiotherapy courses, phases, and treatment plans is shown here. A course of therapy systematically addresses a condition or set of related conditions. The course can include multiple sessions, can be divided into multiple phases, and can last for several months. A course of treatment has a distinct beginning and end. While the Radiotherapy Course Summary can be incrementally updated as the treatment progresses, the primary purpose is to summarize the entire course of treatment from beginning to end. The status element indicates whether the treatment is in progress or complete. The relationships between the various radiotherapy profiles are shown here.
Procedure resources whose code is SNOMEDCT 1217123003
(Radiotherapy course of treatment (regime/therapy)) MUST conform to this profile. Any resource intended to conform to this profile SHOULD populate meta.profile
accordingly.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from RadiotherapyCourseSummary
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Procedure | C | 0..* | RadiotherapyCourseSummary | An action that is being or was performed on a patient codexrt-motion-management-none: If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "Radiotherapy without respiratory motion management (regime/therapy)" codexrt-free-breathing-technique: The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "Radiotherapy with free breathing (regime/therapy)" codexrt-procedure-status: Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed |
extension:modalityAndTechnique | 0..* | RadiotherapyModalityAndTechnique | Radiotherapy Modality And Technique Extension | |
radiotherapyEnergyOrIsotope | S | 0..* | SimpleQuantity | Radiotherapy Energy or Isotope URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Binding: Radiotherapy Energy Unit Value Set (required) |
radiotherapyTreatmentApplicatorType | S | 0..* | CodeableConcept | Radiotherapy Treatment Applicator Type URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type Binding: Brachytherapy Applicator Type Value Set (extensible) |
extension:doseDeliveredToVolume | 0..* | RadiotherapyDoseDeliveredToVolume | Radiotherapy Dose Delivered To Volume Extension | |
extension | 2..* | Extension | Extension | |
pointDose | S | 0..1 | boolean | Point Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose |
primaryPlanDose | S | 0..1 | boolean | Primary Plan Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose |
uniformFractionation | S | 1..1 | boolean | Uniform Fractionation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-uniform-fractionation |
respiratoryMotionManagement | S | 0..* | CodeableConcept | Respiratory Motion Management URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management Binding: Radiotherapy Respiratory Motion Management Value Set (required) |
freeBreathingMotionManagementTechnique | S | 0..* | CodeableConcept | Free-Breathing Motion Management Technique URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique Binding: Radiotherapy Free-Breathing Motion Management Technique Value Set (required) |
imageGuidedRadiotherapyModality | S | 0..* | (Complex) | Image Guided Radiotherapy Modality URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality |
courseInvolvesReirradiation | S | 0..1 | boolean | Course Involves Reirradiation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-course-involves-reirradiation |
Slices for identifier | S | 2..* | Identifier | External Identifiers for this procedure Slice: Unordered, Open by value:use |
identifier:displayName | S | 1..1 | Identifier | The name that is displayed to the user. |
use | 1..1 | code | usual | official | temp | secondary | old (If known) Required Pattern: usual | |
system | S | 1..1 | uri | The namespace for the identifier value |
value | S | 1..1 | string | The value that is unique |
identifier:official | S | 1..* | Identifier | A business identifier for the request or procedure, which is independent of its FHIR representation, such as a GUID or DICOM UID. |
use | 1..1 | code | usual | official | temp | secondary | old (If known) Required Pattern: official | |
system | S | 1..1 | uri | The namespace for the identifier value |
value | S | 1..1 | string | The value that is unique |
Slices for basedOn | 0..* | Reference(CarePlan | ServiceRequest) | A request for this procedure Slice: Unordered, Open by profile:$this.resolve() | |
basedOn:planned-course | S | 0..1 | Reference(Radiotherapy Planned Course) | Radiotherapy Planned Course that planned the treatment summarized in this Radiotherapy Course Summary. |
basedOn:course-prescription | S | 0..1 | Reference(Radiotherapy Course Prescription) | Radiotherapy Course Prescription that prescribed the treatment summarized in this Radiotherapy Course Summary. |
performed[x] | ||||
start | S | 0..1 | dateTime | The date and time when the first therapeutic radiation was delivered. |
end | S | 0..1 | dateTime | An end date is expected if the status is 'stopped' or 'completed' |
location | S | 0..1 | Reference(US Core Location Profile) | Where the procedure happened |
bodySite | ||||
locationQualifier | 0..* | CodeableConcept | General location qualifier (excluding laterality) for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Binding: Body Location Qualifier Value Set (required) | |
lateralityQualifier | 0..1 | CodeableConcept | Laterality qualifier for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Binding: Laterality Qualifier Value Set (required) | |
Slices for focalDevice | 0..* | BackboneElement | Manipulated, implanted, or removed device Slice: Unordered, Open by profile:manipulated.resolve() | |
focalDevice:seedDevice | S | 0..* | BackboneElement | Radiotherapy Seed Device used as part of therapy. |
manipulated | 1..1 | Reference(Radiotherapy Seed Device) | Device that was changed | |
Slices for usedReference | S | 0..* | Reference(Device | Medication | Substance) | Items used during procedure Slice: Unordered, Open by profile:$this.resolve() |
usedReference:treatmentDevice | S | 0..* | Reference(Radiotherapy Treatment Device) | Radiotherapy Treatment Device used as part of therapy. |
Documentation for this format |
Id | Grade | Path(s) | Details | Requirements |
codexrt-free-breathing-technique | error | Procedure | The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing.
SNOMEDCT code 721071000124104 is "Radiotherapy with free breathing (regime/therapy)" : extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique') implies extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721071000124104' and system = 'http://hl7.org/fhir/us/codex-radiation-therapy/CodeSystem/snomed-requested-cs'))) | |
codexrt-motion-management-none | error | Procedure | If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed.
They would also be 'none' or contradict the 'none'.
SNOMEDCT code 721031000124102 is "Radiotherapy without respiratory motion management (regime/therapy)" : extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721031000124102' and system = 'http://hl7.org/fhir/us/codex-radiation-therapy/CodeSystem/snomed-requested-cs'))) implies extension.where(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management').count() = 1 | |
codexrt-procedure-status | error | Procedure | Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed : status = 'in-progress' or status = 'not-done' or status = 'on-hold' or status = 'stopped' or status = 'completed' |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Procedure | C | 0..* | RadiotherapyCourseSummary | An action that is being or was performed on a patient codexrt-motion-management-none: If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "Radiotherapy without respiratory motion management (regime/therapy)" codexrt-free-breathing-technique: The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "Radiotherapy with free breathing (regime/therapy)" codexrt-procedure-status: Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed |
implicitRules | ?!ÎŁ | 0..1 | uri | A set of rules under which this content was created |
Slices for extension | S | 0..* | Extension | Extension Slice: Unordered, Open by value:url |
treatmentIntent | S | 0..1 | CodeableConcept | Procedure Intent Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-procedure-intent Binding: Procedure Intent Value Set (required) |
terminationReason | S | 0..1 | CodeableConcept | Treatment Termination Reason Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-treatment-termination-reason Binding: Treatment Termination Reason Value Set (required) |
modalityAndTechnique | SC | 0..* | (Complex) | Radiotherapy Modality And Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique |
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |
modality | S | 1..1 | CodeableConcept | Radiotherapy Modality Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Modality Value Set (required) | |
technique | S | 0..* | CodeableConcept | Radiotherapy Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Technique Value Set (required) | |
radiotherapyEnergyOrIsotope | S | 0..* | SimpleQuantity | Radiotherapy Energy or Isotope URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Binding: Radiotherapy Energy Unit Value Set (required) |
radiotherapyTreatmentApplicatorType | S | 0..* | CodeableConcept | Radiotherapy Treatment Applicator Type URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type Binding: Brachytherapy Applicator Type Value Set (extensible) |
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique" | |
actualNumberOfSessions | S | 0..1 | unsignedInt | Radiotherapy Number of Sessions Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-sessions |
doseDeliveredToVolume | S | 0..* | (Complex) | Radiotherapy Dose Delivered To Volume Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume |
Slices for extension | 2..* | Extension | Extension Slice: Unordered, Open by value:url | |
extension:volume | S | 1..1 | Extension | Volume in the body where radiation was delivered |
extension | 0..0 | |||
url | 1..1 | uri | "volume" | |
extension:totalDoseDelivered | S | 0..1 | Extension | Total Radiation Dose Delivered |
extension | 0..0 | |||
url | 1..1 | uri | "totalDoseDelivered" | |
Slices for value[x] | 0..1 | Quantity | Value of extension Slice: Unordered, Closed by type:$this | |
value[x]:valueQuantity | 0..1 | Quantity | Value of extension Required Pattern: At least the following | |
system | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |
code | 1..1 | code | Coded form of the unit Fixed Value: cGy | |
extension:fractionsDelivered | S | 0..1 | Extension | Number of Fractions Delivered |
extension | 0..0 | |||
url | 1..1 | uri | "fractionsDelivered" | |
pointDose | S | 0..1 | boolean | Point Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose |
primaryPlanDose | S | 0..1 | boolean | Primary Plan Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose |
uniformFractionation | S | 1..1 | boolean | Uniform Fractionation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-uniform-fractionation |
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume" | |
respiratoryMotionManagement | S | 0..* | CodeableConcept | Respiratory Motion Management URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management Binding: Radiotherapy Respiratory Motion Management Value Set (required) |
freeBreathingMotionManagementTechnique | S | 0..* | CodeableConcept | Free-Breathing Motion Management Technique URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique Binding: Radiotherapy Free-Breathing Motion Management Technique Value Set (required) |
imageGuidedRadiotherapyModality | S | 0..* | (Complex) | Image Guided Radiotherapy Modality URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality |
courseInvolvesReirradiation | S | 0..1 | boolean | Course Involves Reirradiation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-course-involves-reirradiation |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
Slices for identifier | SÎŁ | 2..* | Identifier | External Identifiers for this procedure Slice: Unordered, Open by value:use |
identifier:displayName | SÎŁ | 1..1 | Identifier | The name that is displayed to the user. |
use | ?!ÎŁ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: usual |
system | SÎŁ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
value | SÎŁ | 1..1 | string | The value that is unique Example General: 123456 |
identifier:official | SÎŁ | 1..* | Identifier | A business identifier for the request or procedure, which is independent of its FHIR representation, such as a GUID or DICOM UID. |
use | ?!ÎŁ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: official |
system | SÎŁ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
value | SÎŁ | 1..1 | string | The value that is unique Example General: 123456 |
Slices for basedOn | ÎŁ | 0..* | Reference(CarePlan | ServiceRequest) | A request for this procedure Slice: Unordered, Open by profile:$this.resolve() |
basedOn:planned-course | SÎŁ | 0..1 | Reference(Radiotherapy Planned Course) | Radiotherapy Planned Course that planned the treatment summarized in this Radiotherapy Course Summary. |
basedOn:course-prescription | SÎŁ | 0..1 | Reference(Radiotherapy Course Prescription) | Radiotherapy Course Prescription that prescribed the treatment summarized in this Radiotherapy Course Summary. |
status | ?!SÎŁ | 1..1 | code | preparation | in-progress | not-done | on-hold | stopped | completed | entered-in-error | unknown Binding: EventStatus (required) |
category | SÎŁ | 1..1 | CodeableConcept | Classification of the procedure Binding: ProcedureCategoryCodes(SNOMEDCT) (example): A code that classifies a procedure for searching, sorting and display purposes. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 108290001 | |
code | SÎŁ | 1..1 | CodeableConcept | Identification of the procedure Binding: US Core Procedure Codes (extensible): Codes describing the type of Procedure Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 1217123003 | |
subject | SÎŁ | 1..1 | Reference(Cancer Patient Profile) | Who the procedure was performed on |
performed[x] | SÎŁ | 1..1 | Period | When the procedure was performed |
start | SÎŁC | 0..1 | dateTime | The date and time when the first therapeutic radiation was delivered. |
end | SÎŁC | 0..1 | dateTime | An end date is expected if the status is 'stopped' or 'completed' |
location | SÎŁ | 0..1 | Reference(US Core Location Profile) | Where the procedure happened |
reasonCode | SÎŁ | 0..* | CodeableConcept | Coded reason procedure performed Binding: Cancer Disorder Value Set (extensible) |
reasonReference | SÎŁ | 0..* | Reference(Primary Cancer Condition Profile | Secondary Cancer Condition Profile) | The justification that the procedure was performed |
bodySite | SÎŁ | 0..* | CodeableConcept | All body structure(s) treated Binding: Radiotherapy Treatment Location Value Set (required) |
locationQualifier | 0..* | CodeableConcept | General location qualifier (excluding laterality) for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Binding: Body Location Qualifier Value Set (required) | |
lateralityQualifier | 0..1 | CodeableConcept | Laterality qualifier for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Binding: Laterality Qualifier Value Set (required) | |
Slices for focalDevice | 0..* | BackboneElement | Manipulated, implanted, or removed device Slice: Unordered, Open by profile:manipulated.resolve() | |
focalDevice:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!ÎŁ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
manipulated | 1..1 | Reference(Device) | Device that was changed | |
focalDevice:seedDevice | S | 0..* | BackboneElement | Radiotherapy Seed Device used as part of therapy. |
modifierExtension | ?!ÎŁ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
manipulated | 1..1 | Reference(Radiotherapy Seed Device) | Device that was changed | |
Slices for usedReference | S | 0..* | Reference(Device | Medication | Substance) | Items used during procedure Slice: Unordered, Open by profile:$this.resolve() |
usedReference:treatmentDevice | S | 0..* | Reference(Radiotherapy Treatment Device) | Radiotherapy Treatment Device used as part of therapy. |
Documentation for this format |
Path | Conformance | ValueSet / Code |
Procedure.extension:modalityAndTechnique.extension:modality.value[x] | required | RadiotherapyModalityVS |
Procedure.extension:modalityAndTechnique.extension:technique.value[x] | required | RadiotherapyTechniqueVS |
Procedure.identifier:displayName.use | required | Pattern: usual |
Procedure.identifier:official.use | required | Pattern: official |
Procedure.status | required | EventStatus |
Procedure.category | example | Pattern: SNOMED CT code 108290001 |
Procedure.code | extensible | Pattern: SNOMED CT code 1217123003 |
Procedure.reasonCode | extensible | CancerDisorderVS |
Procedure.bodySite | required | RadiotherapyTreatmentLocationVS |
Id | Grade | Path(s) | Details | Requirements |
codexrt-free-breathing-technique | error | Procedure | The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing.
SNOMEDCT code 721071000124104 is "Radiotherapy with free breathing (regime/therapy)" : extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique') implies extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721071000124104' and system = 'http://hl7.org/fhir/us/codex-radiation-therapy/CodeSystem/snomed-requested-cs'))) | |
codexrt-motion-management-none | error | Procedure | If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed.
They would also be 'none' or contradict the 'none'.
SNOMEDCT code 721031000124102 is "Radiotherapy without respiratory motion management (regime/therapy)" : extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721031000124102' and system = 'http://hl7.org/fhir/us/codex-radiation-therapy/CodeSystem/snomed-requested-cs'))) implies extension.where(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management').count() = 1 | |
codexrt-procedure-status | error | Procedure | Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed : status = 'in-progress' or status = 'not-done' or status = 'on-hold' or status = 'stopped' or status = 'completed' |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Procedure | C | 0..* | RadiotherapyCourseSummary | An action that is being or was performed on a patient codexrt-motion-management-none: If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "Radiotherapy without respiratory motion management (regime/therapy)" codexrt-free-breathing-technique: The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "Radiotherapy with free breathing (regime/therapy)" codexrt-procedure-status: Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed | ||||
id | ÎŁ | 0..1 | id | Logical id of this artifact | ||||
meta | ÎŁ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!ÎŁ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | S | 0..* | Extension | Extension Slice: Unordered, Open by value:url | ||||
treatmentIntent | S | 0..1 | CodeableConcept | Procedure Intent Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-procedure-intent Binding: Procedure Intent Value Set (required) | ||||
terminationReason | S | 0..1 | CodeableConcept | Treatment Termination Reason Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-treatment-termination-reason Binding: Treatment Termination Reason Value Set (required) | ||||
modalityAndTechnique | SC | 0..* | (Complex) | Radiotherapy Modality And Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
modality | S | 1..1 | CodeableConcept | Radiotherapy Modality Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality" | |||||
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Modality Value Set (required) | |||||
technique | S | 0..* | CodeableConcept | Radiotherapy Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique" | |||||
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Technique Value Set (required) | |||||
radiotherapyEnergyOrIsotope | S | 0..* | SimpleQuantity | Radiotherapy Energy or Isotope URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Binding: Radiotherapy Energy Unit Value Set (required) | ||||
radiotherapyTreatmentApplicatorType | S | 0..* | CodeableConcept | Radiotherapy Treatment Applicator Type URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type Binding: Brachytherapy Applicator Type Value Set (extensible) | ||||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique" | |||||
actualNumberOfSessions | S | 0..1 | unsignedInt | Radiotherapy Number of Sessions Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-sessions | ||||
doseDeliveredToVolume | S | 0..* | (Complex) | Radiotherapy Dose Delivered To Volume Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
Slices for extension | 2..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
extension:volume | S | 1..1 | Extension | Volume in the body where radiation was delivered | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "volume" | |||||
value[x] | 0..1 | Reference(Radiotherapy Volume Profile) | Value of extension | |||||
extension:totalDoseDelivered | S | 0..1 | Extension | Total Radiation Dose Delivered | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "totalDoseDelivered" | |||||
Slices for value[x] | 0..1 | Quantity | Value of extension Slice: Unordered, Closed by type:$this | |||||
value[x]:valueQuantity | 0..1 | Quantity | Value of extension Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
value | 0..1 | decimal | Numerical value (with implicit precision) | |||||
comparator | 0..1 | code | < | <= | >= | > - how to understand the value | |||||
unit | 0..1 | string | Unit representation | |||||
system | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |||||
code | 1..1 | code | Coded form of the unit Fixed Value: cGy | |||||
extension:fractionsDelivered | S | 0..1 | Extension | Number of Fractions Delivered | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "fractionsDelivered" | |||||
value[x] | 0..1 | unsignedInt | Value of extension | |||||
pointDose | S | 0..1 | boolean | Point Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose | ||||
primaryPlanDose | S | 0..1 | boolean | Primary Plan Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose | ||||
uniformFractionation | S | 1..1 | boolean | Uniform Fractionation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-uniform-fractionation | ||||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume" | |||||
respiratoryMotionManagement | S | 0..* | CodeableConcept | Respiratory Motion Management URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management Binding: Radiotherapy Respiratory Motion Management Value Set (required) | ||||
freeBreathingMotionManagementTechnique | S | 0..* | CodeableConcept | Free-Breathing Motion Management Technique URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique Binding: Radiotherapy Free-Breathing Motion Management Technique Value Set (required) | ||||
imageGuidedRadiotherapyModality | S | 0..* | (Complex) | Image Guided Radiotherapy Modality URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality | ||||
courseInvolvesReirradiation | S | 0..1 | boolean | Course Involves Reirradiation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-course-involves-reirradiation | ||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
Slices for identifier | SÎŁ | 2..* | Identifier | External Identifiers for this procedure Slice: Unordered, Open by value:use | ||||
identifier:displayName | SÎŁ | 1..1 | Identifier | The name that is displayed to the user. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
use | ?!ÎŁ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: usual | ||||
type | ÎŁ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
system | SÎŁ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
value | SÎŁ | 1..1 | string | The value that is unique Example General: 123456 | ||||
period | ÎŁ | 0..1 | Period | Time period when id is/was valid for use | ||||
assigner | ÎŁ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
identifier:official | SÎŁ | 1..* | Identifier | A business identifier for the request or procedure, which is independent of its FHIR representation, such as a GUID or DICOM UID. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
use | ?!ÎŁ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: official | ||||
type | ÎŁ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
system | SÎŁ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
value | SÎŁ | 1..1 | string | The value that is unique Example General: 123456 | ||||
period | ÎŁ | 0..1 | Period | Time period when id is/was valid for use | ||||
assigner | ÎŁ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
instantiatesCanonical | ÎŁ | 0..* | canonical(PlanDefinition | ActivityDefinition | Measure | OperationDefinition | Questionnaire) | Instantiates FHIR protocol or definition | ||||
instantiatesUri | ÎŁ | 0..* | uri | Instantiates external protocol or definition | ||||
Slices for basedOn | ÎŁ | 0..* | Reference(CarePlan | ServiceRequest) | A request for this procedure Slice: Unordered, Open by profile:$this.resolve() | ||||
basedOn:planned-course | SÎŁ | 0..1 | Reference(Radiotherapy Planned Course) | Radiotherapy Planned Course that planned the treatment summarized in this Radiotherapy Course Summary. | ||||
basedOn:course-prescription | SÎŁ | 0..1 | Reference(Radiotherapy Course Prescription) | Radiotherapy Course Prescription that prescribed the treatment summarized in this Radiotherapy Course Summary. | ||||
partOf | ÎŁ | 0..* | Reference(Procedure | Observation | MedicationAdministration) | Part of referenced event | ||||
status | ?!SÎŁ | 1..1 | code | preparation | in-progress | not-done | on-hold | stopped | completed | entered-in-error | unknown Binding: EventStatus (required) | ||||
statusReason | ÎŁ | 0..1 | CodeableConcept | Reason for current status Binding: ProcedureNotPerformedReason(SNOMED-CT) (example): A code that identifies the reason a procedure was not performed. | ||||
category | SÎŁ | 1..1 | CodeableConcept | Classification of the procedure Binding: ProcedureCategoryCodes(SNOMEDCT) (example): A code that classifies a procedure for searching, sorting and display purposes. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 108290001 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | SÎŁ | 1..1 | CodeableConcept | Identification of the procedure Binding: US Core Procedure Codes (extensible): Codes describing the type of Procedure Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 1217123003 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | SÎŁ | 1..1 | Reference(Cancer Patient Profile) | Who the procedure was performed on | ||||
encounter | ÎŁ | 0..1 | Reference(Encounter) | Encounter created as part of | ||||
performed[x] | SÎŁ | 1..1 | Period | When the procedure was performed | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
start | SÎŁC | 0..1 | dateTime | The date and time when the first therapeutic radiation was delivered. | ||||
end | SÎŁC | 0..1 | dateTime | An end date is expected if the status is 'stopped' or 'completed' | ||||
recorder | ÎŁ | 0..1 | Reference(Patient | RelatedPerson | Practitioner | PractitionerRole) | Who recorded the procedure | ||||
asserter | ÎŁ | 0..1 | Reference(Patient | RelatedPerson | Practitioner | PractitionerRole) | Person who asserts this procedure | ||||
performer | ÎŁ | 0..* | BackboneElement | The people who performed the procedure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!ÎŁ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
function | ÎŁ | 0..1 | CodeableConcept | Type of performance Binding: ProcedurePerformerRoleCodes (example): A code that identifies the role of a performer of the procedure. | ||||
actor | ÎŁ | 1..1 | Reference(Practitioner | PractitionerRole | Organization | Patient | RelatedPerson | Device) | The reference to the practitioner | ||||
onBehalfOf | 0..1 | Reference(Organization) | Organization the device or practitioner was acting for | |||||
location | SÎŁ | 0..1 | Reference(US Core Location Profile) | Where the procedure happened | ||||
reasonCode | SÎŁ | 0..* | CodeableConcept | Coded reason procedure performed Binding: Cancer Disorder Value Set (extensible) | ||||
reasonReference | SÎŁ | 0..* | Reference(Primary Cancer Condition Profile | Secondary Cancer Condition Profile) | The justification that the procedure was performed | ||||
bodySite | SÎŁ | 0..* | CodeableConcept | All body structure(s) treated Binding: Radiotherapy Treatment Location Value Set (required) | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
Slices for extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
locationQualifier | 0..* | CodeableConcept | General location qualifier (excluding laterality) for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Binding: Body Location Qualifier Value Set (required) | |||||
lateralityQualifier | 0..1 | CodeableConcept | Laterality qualifier for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Binding: Laterality Qualifier Value Set (required) | |||||
coding | ÎŁ | 0..* | Coding | Code defined by a terminology system | ||||
text | ÎŁ | 0..1 | string | Plain text representation of the concept | ||||
outcome | ÎŁ | 0..1 | CodeableConcept | The result of procedure Binding: ProcedureOutcomeCodes(SNOMEDCT) (example): An outcome of a procedure - whether it was resolved or otherwise. | ||||
report | 0..* | Reference(DiagnosticReport | DocumentReference | Composition) | Any report resulting from the procedure | |||||
complication | 0..* | CodeableConcept | Complication following the procedure Binding: Condition/Problem/DiagnosisCodes (example): Codes describing complications that resulted from a procedure. | |||||
complicationDetail | 0..* | Reference(Condition) | A condition that is a result of the procedure | |||||
followUp | 0..* | CodeableConcept | Instructions for follow up Binding: ProcedureFollowUpCodes(SNOMEDCT) (example): Specific follow up required for a procedure e.g. removal of sutures. | |||||
note | 0..* | Annotation | Additional information about the procedure | |||||
Slices for focalDevice | 0..* | BackboneElement | Manipulated, implanted, or removed device Slice: Unordered, Open by profile:manipulated.resolve() | |||||
focalDevice:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!ÎŁ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
action | 0..1 | CodeableConcept | Kind of change to device Binding: ProcedureDeviceActionCodes (preferred): A kind of change that happened to the device during the procedure. | |||||
manipulated | 1..1 | Reference(Device) | Device that was changed | |||||
focalDevice:seedDevice | S | 0..* | BackboneElement | Radiotherapy Seed Device used as part of therapy. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!ÎŁ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
action | 0..1 | CodeableConcept | Kind of change to device Binding: ProcedureDeviceActionCodes (preferred): A kind of change that happened to the device during the procedure. | |||||
manipulated | 1..1 | Reference(Radiotherapy Seed Device) | Device that was changed | |||||
Slices for usedReference | S | 0..* | Reference(Device | Medication | Substance) | Items used during procedure Slice: Unordered, Open by profile:$this.resolve() | ||||
usedReference:treatmentDevice | S | 0..* | Reference(Radiotherapy Treatment Device) | Radiotherapy Treatment Device used as part of therapy. | ||||
usedCode | 0..* | CodeableConcept | Coded items used during the procedure Binding: FHIRDeviceTypes (example): Codes describing items used during a procedure. | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | ||||
Procedure.language | preferred | CommonLanguages
| ||||
Procedure.extension:modalityAndTechnique.extension:modality.value[x] | required | RadiotherapyModalityVS | ||||
Procedure.extension:modalityAndTechnique.extension:technique.value[x] | required | RadiotherapyTechniqueVS | ||||
Procedure.identifier:displayName.use | required | Pattern: usual | ||||
Procedure.identifier:displayName.type | extensible | Identifier Type Codes | ||||
Procedure.identifier:official.use | required | Pattern: official | ||||
Procedure.identifier:official.type | extensible | Identifier Type Codes | ||||
Procedure.status | required | EventStatus | ||||
Procedure.statusReason | example | ProcedureNotPerformedReason(SNOMED-CT) | ||||
Procedure.category | example | Pattern: SNOMED CT code 108290001 | ||||
Procedure.code | extensible | Pattern: SNOMED CT code 1217123003 | ||||
Procedure.performer.function | example | ProcedurePerformerRoleCodes | ||||
Procedure.reasonCode | extensible | CancerDisorderVS | ||||
Procedure.bodySite | required | RadiotherapyTreatmentLocationVS | ||||
Procedure.outcome | example | ProcedureOutcomeCodes(SNOMEDCT) | ||||
Procedure.complication | example | Condition/Problem/DiagnosisCodes | ||||
Procedure.followUp | example | ProcedureFollowUpCodes(SNOMEDCT) | ||||
Procedure.focalDevice.action | preferred | ProcedureDeviceActionCodes | ||||
Procedure.focalDevice:seedDevice.action | preferred | ProcedureDeviceActionCodes | ||||
Procedure.usedCode | example | FHIRDeviceTypes |
This structure is derived from RadiotherapyCourseSummary
Summary
Mandatory: 8 elements (1 nested mandatory element)
Must-Support: 24 elements
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Differential View
This structure is derived from RadiotherapyCourseSummary
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Procedure | C | 0..* | RadiotherapyCourseSummary | An action that is being or was performed on a patient codexrt-motion-management-none: If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "Radiotherapy without respiratory motion management (regime/therapy)" codexrt-free-breathing-technique: The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "Radiotherapy with free breathing (regime/therapy)" codexrt-procedure-status: Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed |
extension:modalityAndTechnique | 0..* | RadiotherapyModalityAndTechnique | Radiotherapy Modality And Technique Extension | |
radiotherapyEnergyOrIsotope | S | 0..* | SimpleQuantity | Radiotherapy Energy or Isotope URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Binding: Radiotherapy Energy Unit Value Set (required) |
radiotherapyTreatmentApplicatorType | S | 0..* | CodeableConcept | Radiotherapy Treatment Applicator Type URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type Binding: Brachytherapy Applicator Type Value Set (extensible) |
extension:doseDeliveredToVolume | 0..* | RadiotherapyDoseDeliveredToVolume | Radiotherapy Dose Delivered To Volume Extension | |
extension | 2..* | Extension | Extension | |
pointDose | S | 0..1 | boolean | Point Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose |
primaryPlanDose | S | 0..1 | boolean | Primary Plan Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose |
uniformFractionation | S | 1..1 | boolean | Uniform Fractionation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-uniform-fractionation |
respiratoryMotionManagement | S | 0..* | CodeableConcept | Respiratory Motion Management URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management Binding: Radiotherapy Respiratory Motion Management Value Set (required) |
freeBreathingMotionManagementTechnique | S | 0..* | CodeableConcept | Free-Breathing Motion Management Technique URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique Binding: Radiotherapy Free-Breathing Motion Management Technique Value Set (required) |
imageGuidedRadiotherapyModality | S | 0..* | (Complex) | Image Guided Radiotherapy Modality URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality |
courseInvolvesReirradiation | S | 0..1 | boolean | Course Involves Reirradiation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-course-involves-reirradiation |
Slices for identifier | S | 2..* | Identifier | External Identifiers for this procedure Slice: Unordered, Open by value:use |
identifier:displayName | S | 1..1 | Identifier | The name that is displayed to the user. |
use | 1..1 | code | usual | official | temp | secondary | old (If known) Required Pattern: usual | |
system | S | 1..1 | uri | The namespace for the identifier value |
value | S | 1..1 | string | The value that is unique |
identifier:official | S | 1..* | Identifier | A business identifier for the request or procedure, which is independent of its FHIR representation, such as a GUID or DICOM UID. |
use | 1..1 | code | usual | official | temp | secondary | old (If known) Required Pattern: official | |
system | S | 1..1 | uri | The namespace for the identifier value |
value | S | 1..1 | string | The value that is unique |
Slices for basedOn | 0..* | Reference(CarePlan | ServiceRequest) | A request for this procedure Slice: Unordered, Open by profile:$this.resolve() | |
basedOn:planned-course | S | 0..1 | Reference(Radiotherapy Planned Course) | Radiotherapy Planned Course that planned the treatment summarized in this Radiotherapy Course Summary. |
basedOn:course-prescription | S | 0..1 | Reference(Radiotherapy Course Prescription) | Radiotherapy Course Prescription that prescribed the treatment summarized in this Radiotherapy Course Summary. |
performed[x] | ||||
start | S | 0..1 | dateTime | The date and time when the first therapeutic radiation was delivered. |
end | S | 0..1 | dateTime | An end date is expected if the status is 'stopped' or 'completed' |
location | S | 0..1 | Reference(US Core Location Profile) | Where the procedure happened |
bodySite | ||||
locationQualifier | 0..* | CodeableConcept | General location qualifier (excluding laterality) for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Binding: Body Location Qualifier Value Set (required) | |
lateralityQualifier | 0..1 | CodeableConcept | Laterality qualifier for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Binding: Laterality Qualifier Value Set (required) | |
Slices for focalDevice | 0..* | BackboneElement | Manipulated, implanted, or removed device Slice: Unordered, Open by profile:manipulated.resolve() | |
focalDevice:seedDevice | S | 0..* | BackboneElement | Radiotherapy Seed Device used as part of therapy. |
manipulated | 1..1 | Reference(Radiotherapy Seed Device) | Device that was changed | |
Slices for usedReference | S | 0..* | Reference(Device | Medication | Substance) | Items used during procedure Slice: Unordered, Open by profile:$this.resolve() |
usedReference:treatmentDevice | S | 0..* | Reference(Radiotherapy Treatment Device) | Radiotherapy Treatment Device used as part of therapy. |
Documentation for this format |
Id | Grade | Path(s) | Details | Requirements |
codexrt-free-breathing-technique | error | Procedure | The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing.
SNOMEDCT code 721071000124104 is "Radiotherapy with free breathing (regime/therapy)" : extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique') implies extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721071000124104' and system = 'http://hl7.org/fhir/us/codex-radiation-therapy/CodeSystem/snomed-requested-cs'))) | |
codexrt-motion-management-none | error | Procedure | If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed.
They would also be 'none' or contradict the 'none'.
SNOMEDCT code 721031000124102 is "Radiotherapy without respiratory motion management (regime/therapy)" : extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721031000124102' and system = 'http://hl7.org/fhir/us/codex-radiation-therapy/CodeSystem/snomed-requested-cs'))) implies extension.where(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management').count() = 1 | |
codexrt-procedure-status | error | Procedure | Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed : status = 'in-progress' or status = 'not-done' or status = 'on-hold' or status = 'stopped' or status = 'completed' |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Procedure | C | 0..* | RadiotherapyCourseSummary | An action that is being or was performed on a patient codexrt-motion-management-none: If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "Radiotherapy without respiratory motion management (regime/therapy)" codexrt-free-breathing-technique: The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "Radiotherapy with free breathing (regime/therapy)" codexrt-procedure-status: Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed |
implicitRules | ?!ÎŁ | 0..1 | uri | A set of rules under which this content was created |
Slices for extension | S | 0..* | Extension | Extension Slice: Unordered, Open by value:url |
treatmentIntent | S | 0..1 | CodeableConcept | Procedure Intent Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-procedure-intent Binding: Procedure Intent Value Set (required) |
terminationReason | S | 0..1 | CodeableConcept | Treatment Termination Reason Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-treatment-termination-reason Binding: Treatment Termination Reason Value Set (required) |
modalityAndTechnique | SC | 0..* | (Complex) | Radiotherapy Modality And Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique |
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |
modality | S | 1..1 | CodeableConcept | Radiotherapy Modality Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Modality Value Set (required) | |
technique | S | 0..* | CodeableConcept | Radiotherapy Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Technique Value Set (required) | |
radiotherapyEnergyOrIsotope | S | 0..* | SimpleQuantity | Radiotherapy Energy or Isotope URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Binding: Radiotherapy Energy Unit Value Set (required) |
radiotherapyTreatmentApplicatorType | S | 0..* | CodeableConcept | Radiotherapy Treatment Applicator Type URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type Binding: Brachytherapy Applicator Type Value Set (extensible) |
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique" | |
actualNumberOfSessions | S | 0..1 | unsignedInt | Radiotherapy Number of Sessions Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-sessions |
doseDeliveredToVolume | S | 0..* | (Complex) | Radiotherapy Dose Delivered To Volume Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume |
Slices for extension | 2..* | Extension | Extension Slice: Unordered, Open by value:url | |
extension:volume | S | 1..1 | Extension | Volume in the body where radiation was delivered |
extension | 0..0 | |||
url | 1..1 | uri | "volume" | |
extension:totalDoseDelivered | S | 0..1 | Extension | Total Radiation Dose Delivered |
extension | 0..0 | |||
url | 1..1 | uri | "totalDoseDelivered" | |
Slices for value[x] | 0..1 | Quantity | Value of extension Slice: Unordered, Closed by type:$this | |
value[x]:valueQuantity | 0..1 | Quantity | Value of extension Required Pattern: At least the following | |
system | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |
code | 1..1 | code | Coded form of the unit Fixed Value: cGy | |
extension:fractionsDelivered | S | 0..1 | Extension | Number of Fractions Delivered |
extension | 0..0 | |||
url | 1..1 | uri | "fractionsDelivered" | |
pointDose | S | 0..1 | boolean | Point Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose |
primaryPlanDose | S | 0..1 | boolean | Primary Plan Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose |
uniformFractionation | S | 1..1 | boolean | Uniform Fractionation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-uniform-fractionation |
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume" | |
respiratoryMotionManagement | S | 0..* | CodeableConcept | Respiratory Motion Management URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management Binding: Radiotherapy Respiratory Motion Management Value Set (required) |
freeBreathingMotionManagementTechnique | S | 0..* | CodeableConcept | Free-Breathing Motion Management Technique URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique Binding: Radiotherapy Free-Breathing Motion Management Technique Value Set (required) |
imageGuidedRadiotherapyModality | S | 0..* | (Complex) | Image Guided Radiotherapy Modality URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality |
courseInvolvesReirradiation | S | 0..1 | boolean | Course Involves Reirradiation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-course-involves-reirradiation |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
Slices for identifier | SÎŁ | 2..* | Identifier | External Identifiers for this procedure Slice: Unordered, Open by value:use |
identifier:displayName | SÎŁ | 1..1 | Identifier | The name that is displayed to the user. |
use | ?!ÎŁ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: usual |
system | SÎŁ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
value | SÎŁ | 1..1 | string | The value that is unique Example General: 123456 |
identifier:official | SÎŁ | 1..* | Identifier | A business identifier for the request or procedure, which is independent of its FHIR representation, such as a GUID or DICOM UID. |
use | ?!ÎŁ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: official |
system | SÎŁ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
value | SÎŁ | 1..1 | string | The value that is unique Example General: 123456 |
Slices for basedOn | ÎŁ | 0..* | Reference(CarePlan | ServiceRequest) | A request for this procedure Slice: Unordered, Open by profile:$this.resolve() |
basedOn:planned-course | SÎŁ | 0..1 | Reference(Radiotherapy Planned Course) | Radiotherapy Planned Course that planned the treatment summarized in this Radiotherapy Course Summary. |
basedOn:course-prescription | SÎŁ | 0..1 | Reference(Radiotherapy Course Prescription) | Radiotherapy Course Prescription that prescribed the treatment summarized in this Radiotherapy Course Summary. |
status | ?!SÎŁ | 1..1 | code | preparation | in-progress | not-done | on-hold | stopped | completed | entered-in-error | unknown Binding: EventStatus (required) |
category | SÎŁ | 1..1 | CodeableConcept | Classification of the procedure Binding: ProcedureCategoryCodes(SNOMEDCT) (example): A code that classifies a procedure for searching, sorting and display purposes. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 108290001 | |
code | SÎŁ | 1..1 | CodeableConcept | Identification of the procedure Binding: US Core Procedure Codes (extensible): Codes describing the type of Procedure Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 1217123003 | |
subject | SÎŁ | 1..1 | Reference(Cancer Patient Profile) | Who the procedure was performed on |
performed[x] | SÎŁ | 1..1 | Period | When the procedure was performed |
start | SÎŁC | 0..1 | dateTime | The date and time when the first therapeutic radiation was delivered. |
end | SÎŁC | 0..1 | dateTime | An end date is expected if the status is 'stopped' or 'completed' |
location | SÎŁ | 0..1 | Reference(US Core Location Profile) | Where the procedure happened |
reasonCode | SÎŁ | 0..* | CodeableConcept | Coded reason procedure performed Binding: Cancer Disorder Value Set (extensible) |
reasonReference | SÎŁ | 0..* | Reference(Primary Cancer Condition Profile | Secondary Cancer Condition Profile) | The justification that the procedure was performed |
bodySite | SÎŁ | 0..* | CodeableConcept | All body structure(s) treated Binding: Radiotherapy Treatment Location Value Set (required) |
locationQualifier | 0..* | CodeableConcept | General location qualifier (excluding laterality) for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Binding: Body Location Qualifier Value Set (required) | |
lateralityQualifier | 0..1 | CodeableConcept | Laterality qualifier for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Binding: Laterality Qualifier Value Set (required) | |
Slices for focalDevice | 0..* | BackboneElement | Manipulated, implanted, or removed device Slice: Unordered, Open by profile:manipulated.resolve() | |
focalDevice:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!ÎŁ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
manipulated | 1..1 | Reference(Device) | Device that was changed | |
focalDevice:seedDevice | S | 0..* | BackboneElement | Radiotherapy Seed Device used as part of therapy. |
modifierExtension | ?!ÎŁ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
manipulated | 1..1 | Reference(Radiotherapy Seed Device) | Device that was changed | |
Slices for usedReference | S | 0..* | Reference(Device | Medication | Substance) | Items used during procedure Slice: Unordered, Open by profile:$this.resolve() |
usedReference:treatmentDevice | S | 0..* | Reference(Radiotherapy Treatment Device) | Radiotherapy Treatment Device used as part of therapy. |
Documentation for this format |
Path | Conformance | ValueSet / Code |
Procedure.extension:modalityAndTechnique.extension:modality.value[x] | required | RadiotherapyModalityVS |
Procedure.extension:modalityAndTechnique.extension:technique.value[x] | required | RadiotherapyTechniqueVS |
Procedure.identifier:displayName.use | required | Pattern: usual |
Procedure.identifier:official.use | required | Pattern: official |
Procedure.status | required | EventStatus |
Procedure.category | example | Pattern: SNOMED CT code 108290001 |
Procedure.code | extensible | Pattern: SNOMED CT code 1217123003 |
Procedure.reasonCode | extensible | CancerDisorderVS |
Procedure.bodySite | required | RadiotherapyTreatmentLocationVS |
Id | Grade | Path(s) | Details | Requirements |
codexrt-free-breathing-technique | error | Procedure | The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing.
SNOMEDCT code 721071000124104 is "Radiotherapy with free breathing (regime/therapy)" : extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique') implies extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721071000124104' and system = 'http://hl7.org/fhir/us/codex-radiation-therapy/CodeSystem/snomed-requested-cs'))) | |
codexrt-motion-management-none | error | Procedure | If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed.
They would also be 'none' or contradict the 'none'.
SNOMEDCT code 721031000124102 is "Radiotherapy without respiratory motion management (regime/therapy)" : extension.exists(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management' and value.exists(coding.exists(code = '721031000124102' and system = 'http://hl7.org/fhir/us/codex-radiation-therapy/CodeSystem/snomed-requested-cs'))) implies extension.where(url = 'http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management').count() = 1 | |
codexrt-procedure-status | error | Procedure | Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed : status = 'in-progress' or status = 'not-done' or status = 'on-hold' or status = 'stopped' or status = 'completed' |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Procedure | C | 0..* | RadiotherapyCourseSummary | An action that is being or was performed on a patient codexrt-motion-management-none: If the respiratory motion management is 'none', then no other respiratory motion management extensions are allowed. They would also be 'none' or contradict the 'none'. SNOMEDCT code 721031000124102 is "Radiotherapy without respiratory motion management (regime/therapy)" codexrt-free-breathing-technique: The extension for the technique of free-breathing motion management is only allowed if motion management is free-breathing. SNOMEDCT code 721071000124104 is "Radiotherapy with free breathing (regime/therapy)" codexrt-procedure-status: Only the following status values are supported: in-progress | not-done | on-hold | stopped | completed | ||||
id | ÎŁ | 0..1 | id | Logical id of this artifact | ||||
meta | ÎŁ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!ÎŁ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | S | 0..* | Extension | Extension Slice: Unordered, Open by value:url | ||||
treatmentIntent | S | 0..1 | CodeableConcept | Procedure Intent Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-procedure-intent Binding: Procedure Intent Value Set (required) | ||||
terminationReason | S | 0..1 | CodeableConcept | Treatment Termination Reason Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-treatment-termination-reason Binding: Treatment Termination Reason Value Set (required) | ||||
modalityAndTechnique | SC | 0..* | (Complex) | Radiotherapy Modality And Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
modality | S | 1..1 | CodeableConcept | Radiotherapy Modality Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality" | |||||
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Modality Value Set (required) | |||||
technique | S | 0..* | CodeableConcept | Radiotherapy Technique Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique" | |||||
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Radiotherapy Technique Value Set (required) | |||||
radiotherapyEnergyOrIsotope | S | 0..* | SimpleQuantity | Radiotherapy Energy or Isotope URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Binding: Radiotherapy Energy Unit Value Set (required) | ||||
radiotherapyTreatmentApplicatorType | S | 0..* | CodeableConcept | Radiotherapy Treatment Applicator Type URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treatment-applicator-type Binding: Brachytherapy Applicator Type Value Set (extensible) | ||||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique" | |||||
actualNumberOfSessions | S | 0..1 | unsignedInt | Radiotherapy Number of Sessions Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-sessions | ||||
doseDeliveredToVolume | S | 0..* | (Complex) | Radiotherapy Dose Delivered To Volume Extension URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
Slices for extension | 2..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
extension:volume | S | 1..1 | Extension | Volume in the body where radiation was delivered | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "volume" | |||||
value[x] | 0..1 | Reference(Radiotherapy Volume Profile) | Value of extension | |||||
extension:totalDoseDelivered | S | 0..1 | Extension | Total Radiation Dose Delivered | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "totalDoseDelivered" | |||||
Slices for value[x] | 0..1 | Quantity | Value of extension Slice: Unordered, Closed by type:$this | |||||
value[x]:valueQuantity | 0..1 | Quantity | Value of extension Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
value | 0..1 | decimal | Numerical value (with implicit precision) | |||||
comparator | 0..1 | code | < | <= | >= | > - how to understand the value | |||||
unit | 0..1 | string | Unit representation | |||||
system | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | |||||
code | 1..1 | code | Coded form of the unit Fixed Value: cGy | |||||
extension:fractionsDelivered | S | 0..1 | Extension | Number of Fractions Delivered | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "fractionsDelivered" | |||||
value[x] | 0..1 | unsignedInt | Value of extension | |||||
pointDose | S | 0..1 | boolean | Point Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-point-dose | ||||
primaryPlanDose | S | 0..1 | boolean | Primary Plan Dose URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-primary-plan-dose | ||||
uniformFractionation | S | 1..1 | boolean | Uniform Fractionation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-uniform-fractionation | ||||
url | 1..1 | uri | "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume" | |||||
respiratoryMotionManagement | S | 0..* | CodeableConcept | Respiratory Motion Management URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-respiratory-motion-management Binding: Radiotherapy Respiratory Motion Management Value Set (required) | ||||
freeBreathingMotionManagementTechnique | S | 0..* | CodeableConcept | Free-Breathing Motion Management Technique URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-free-breathing-motion-mgmt-technique Binding: Radiotherapy Free-Breathing Motion Management Technique Value Set (required) | ||||
imageGuidedRadiotherapyModality | S | 0..* | (Complex) | Image Guided Radiotherapy Modality URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality | ||||
courseInvolvesReirradiation | S | 0..1 | boolean | Course Involves Reirradiation URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-course-involves-reirradiation | ||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
Slices for identifier | SÎŁ | 2..* | Identifier | External Identifiers for this procedure Slice: Unordered, Open by value:use | ||||
identifier:displayName | SÎŁ | 1..1 | Identifier | The name that is displayed to the user. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
use | ?!ÎŁ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: usual | ||||
type | ÎŁ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
system | SÎŁ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
value | SÎŁ | 1..1 | string | The value that is unique Example General: 123456 | ||||
period | ÎŁ | 0..1 | Period | Time period when id is/was valid for use | ||||
assigner | ÎŁ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
identifier:official | SÎŁ | 1..* | Identifier | A business identifier for the request or procedure, which is independent of its FHIR representation, such as a GUID or DICOM UID. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
use | ?!ÎŁ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Required Pattern: official | ||||
type | ÎŁ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
system | SÎŁ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
value | SÎŁ | 1..1 | string | The value that is unique Example General: 123456 | ||||
period | ÎŁ | 0..1 | Period | Time period when id is/was valid for use | ||||
assigner | ÎŁ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
instantiatesCanonical | ÎŁ | 0..* | canonical(PlanDefinition | ActivityDefinition | Measure | OperationDefinition | Questionnaire) | Instantiates FHIR protocol or definition | ||||
instantiatesUri | ÎŁ | 0..* | uri | Instantiates external protocol or definition | ||||
Slices for basedOn | ÎŁ | 0..* | Reference(CarePlan | ServiceRequest) | A request for this procedure Slice: Unordered, Open by profile:$this.resolve() | ||||
basedOn:planned-course | SÎŁ | 0..1 | Reference(Radiotherapy Planned Course) | Radiotherapy Planned Course that planned the treatment summarized in this Radiotherapy Course Summary. | ||||
basedOn:course-prescription | SÎŁ | 0..1 | Reference(Radiotherapy Course Prescription) | Radiotherapy Course Prescription that prescribed the treatment summarized in this Radiotherapy Course Summary. | ||||
partOf | ÎŁ | 0..* | Reference(Procedure | Observation | MedicationAdministration) | Part of referenced event | ||||
status | ?!SÎŁ | 1..1 | code | preparation | in-progress | not-done | on-hold | stopped | completed | entered-in-error | unknown Binding: EventStatus (required) | ||||
statusReason | ÎŁ | 0..1 | CodeableConcept | Reason for current status Binding: ProcedureNotPerformedReason(SNOMED-CT) (example): A code that identifies the reason a procedure was not performed. | ||||
category | SÎŁ | 1..1 | CodeableConcept | Classification of the procedure Binding: ProcedureCategoryCodes(SNOMEDCT) (example): A code that classifies a procedure for searching, sorting and display purposes. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 108290001 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | SÎŁ | 1..1 | CodeableConcept | Identification of the procedure Binding: US Core Procedure Codes (extensible): Codes describing the type of Procedure Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 1217123003 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | SÎŁ | 1..1 | Reference(Cancer Patient Profile) | Who the procedure was performed on | ||||
encounter | ÎŁ | 0..1 | Reference(Encounter) | Encounter created as part of | ||||
performed[x] | SÎŁ | 1..1 | Period | When the procedure was performed | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
start | SÎŁC | 0..1 | dateTime | The date and time when the first therapeutic radiation was delivered. | ||||
end | SÎŁC | 0..1 | dateTime | An end date is expected if the status is 'stopped' or 'completed' | ||||
recorder | ÎŁ | 0..1 | Reference(Patient | RelatedPerson | Practitioner | PractitionerRole) | Who recorded the procedure | ||||
asserter | ÎŁ | 0..1 | Reference(Patient | RelatedPerson | Practitioner | PractitionerRole) | Person who asserts this procedure | ||||
performer | ÎŁ | 0..* | BackboneElement | The people who performed the procedure | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!ÎŁ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
function | ÎŁ | 0..1 | CodeableConcept | Type of performance Binding: ProcedurePerformerRoleCodes (example): A code that identifies the role of a performer of the procedure. | ||||
actor | ÎŁ | 1..1 | Reference(Practitioner | PractitionerRole | Organization | Patient | RelatedPerson | Device) | The reference to the practitioner | ||||
onBehalfOf | 0..1 | Reference(Organization) | Organization the device or practitioner was acting for | |||||
location | SÎŁ | 0..1 | Reference(US Core Location Profile) | Where the procedure happened | ||||
reasonCode | SÎŁ | 0..* | CodeableConcept | Coded reason procedure performed Binding: Cancer Disorder Value Set (extensible) | ||||
reasonReference | SÎŁ | 0..* | Reference(Primary Cancer Condition Profile | Secondary Cancer Condition Profile) | The justification that the procedure was performed | ||||
bodySite | SÎŁ | 0..* | CodeableConcept | All body structure(s) treated Binding: Radiotherapy Treatment Location Value Set (required) | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
Slices for extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
locationQualifier | 0..* | CodeableConcept | General location qualifier (excluding laterality) for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-body-location-qualifier Binding: Body Location Qualifier Value Set (required) | |||||
lateralityQualifier | 0..1 | CodeableConcept | Laterality qualifier for this bodySite URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier Binding: Laterality Qualifier Value Set (required) | |||||
coding | ÎŁ | 0..* | Coding | Code defined by a terminology system | ||||
text | ÎŁ | 0..1 | string | Plain text representation of the concept | ||||
outcome | ÎŁ | 0..1 | CodeableConcept | The result of procedure Binding: ProcedureOutcomeCodes(SNOMEDCT) (example): An outcome of a procedure - whether it was resolved or otherwise. | ||||
report | 0..* | Reference(DiagnosticReport | DocumentReference | Composition) | Any report resulting from the procedure | |||||
complication | 0..* | CodeableConcept | Complication following the procedure Binding: Condition/Problem/DiagnosisCodes (example): Codes describing complications that resulted from a procedure. | |||||
complicationDetail | 0..* | Reference(Condition) | A condition that is a result of the procedure | |||||
followUp | 0..* | CodeableConcept | Instructions for follow up Binding: ProcedureFollowUpCodes(SNOMEDCT) (example): Specific follow up required for a procedure e.g. removal of sutures. | |||||
note | 0..* | Annotation | Additional information about the procedure | |||||
Slices for focalDevice | 0..* | BackboneElement | Manipulated, implanted, or removed device Slice: Unordered, Open by profile:manipulated.resolve() | |||||
focalDevice:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!ÎŁ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
action | 0..1 | CodeableConcept | Kind of change to device Binding: ProcedureDeviceActionCodes (preferred): A kind of change that happened to the device during the procedure. | |||||
manipulated | 1..1 | Reference(Device) | Device that was changed | |||||
focalDevice:seedDevice | S | 0..* | BackboneElement | Radiotherapy Seed Device used as part of therapy. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!ÎŁ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
action | 0..1 | CodeableConcept | Kind of change to device Binding: ProcedureDeviceActionCodes (preferred): A kind of change that happened to the device during the procedure. | |||||
manipulated | 1..1 | Reference(Radiotherapy Seed Device) | Device that was changed | |||||
Slices for usedReference | S | 0..* | Reference(Device | Medication | Substance) | Items used during procedure Slice: Unordered, Open by profile:$this.resolve() | ||||
usedReference:treatmentDevice | S | 0..* | Reference(Radiotherapy Treatment Device) | Radiotherapy Treatment Device used as part of therapy. | ||||
usedCode | 0..* | CodeableConcept | Coded items used during the procedure Binding: FHIRDeviceTypes (example): Codes describing items used during a procedure. | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | ||||
Procedure.language | preferred | CommonLanguages
| ||||
Procedure.extension:modalityAndTechnique.extension:modality.value[x] | required | RadiotherapyModalityVS | ||||
Procedure.extension:modalityAndTechnique.extension:technique.value[x] | required | RadiotherapyTechniqueVS | ||||
Procedure.identifier:displayName.use | required | Pattern: usual | ||||
Procedure.identifier:displayName.type | extensible | Identifier Type Codes | ||||
Procedure.identifier:official.use | required | Pattern: official | ||||
Procedure.identifier:official.type | extensible | Identifier Type Codes | ||||
Procedure.status | required | EventStatus | ||||
Procedure.statusReason | example | ProcedureNotPerformedReason(SNOMED-CT) | ||||
Procedure.category | example | Pattern: SNOMED CT code 108290001 | ||||
Procedure.code | extensible | Pattern: SNOMED CT code 1217123003 | ||||
Procedure.performer.function | example | ProcedurePerformerRoleCodes | ||||
Procedure.reasonCode | extensible | CancerDisorderVS | ||||
Procedure.bodySite | required | RadiotherapyTreatmentLocationVS | ||||
Procedure.outcome | example | ProcedureOutcomeCodes(SNOMEDCT) | ||||
Procedure.complication | example | Condition/Problem/DiagnosisCodes | ||||
Procedure.followUp | example | ProcedureFollowUpCodes(SNOMEDCT) | ||||
Procedure.focalDevice.action | preferred | ProcedureDeviceActionCodes | ||||
Procedure.focalDevice:seedDevice.action | preferred | ProcedureDeviceActionCodes | ||||
Procedure.usedCode | example | FHIRDeviceTypes |
This structure is derived from RadiotherapyCourseSummary
Summary
Mandatory: 8 elements (1 nested mandatory element)
Must-Support: 24 elements
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron