This page is part of the CodeX™ Radiation Therapy (v1.0.0: STU 1) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality | Version: 1.0.0 | |||
Draft as of 2023-07-28 | Computable Name: ImageGuidedRadiotherapyModality |
The modality and associated energy used for imaging in Image Guided Radiotherapy (IGRT)
Context of Use
This extension may be used on the following element(s):
Usage info
Usage:
Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.
This structure is derived from Extension
This structure is derived from Extension
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | C | 0..* | Extension | Image Guided Radiotherapy Modality IGRTEnergyAllowed: Energy is only allowed for X-Ray, Fluorograph, or CT Modalities. |
extension | 1..* | Extension | Extension | |
extension:modality | S | 1..1 | Extension | Extension |
extension | 0..0 | |||
url | 1..1 | uri | "modality" | |
value[x] | 0..1 | CodeableConcept | Value of extension Binding: Image Guided Radiotherapy Modality Value Set (required) | |
extension:energy | S | 0..1 | Extension | Extension |
extension | 0..0 | |||
url | 1..1 | uri | "energy" | |
value[x] | 0..1 | CodeableConcept | Value of extension Binding: Image Guided Radiotherapy Energy Unit Value Set (required) | |
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality" | |
value[x] | 0..0 | |||
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | C | 0..* | Extension | Image Guided Radiotherapy Modality IGRTEnergyAllowed: Energy is only allowed for X-Ray, Fluorograph, or CT Modalities. |
id | 0..1 | string | Unique id for inter-element referencing | |
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |
extension:modality | S | 1..1 | Extension | Extension |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "modality" | |
value[x] | 0..1 | CodeableConcept | Value of extension Binding: Image Guided Radiotherapy Modality Value Set (required) | |
extension:energy | S | 0..1 | Extension | Extension |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "energy" | |
value[x] | 0..1 | CodeableConcept | Value of extension Binding: Image Guided Radiotherapy Energy Unit Value Set (required) | |
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality" | |
Documentation for this format |
This structure is derived from Extension
Differential View
This structure is derived from Extension
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | C | 0..* | Extension | Image Guided Radiotherapy Modality IGRTEnergyAllowed: Energy is only allowed for X-Ray, Fluorograph, or CT Modalities. |
extension | 1..* | Extension | Extension | |
extension:modality | S | 1..1 | Extension | Extension |
extension | 0..0 | |||
url | 1..1 | uri | "modality" | |
value[x] | 0..1 | CodeableConcept | Value of extension Binding: Image Guided Radiotherapy Modality Value Set (required) | |
extension:energy | S | 0..1 | Extension | Extension |
extension | 0..0 | |||
url | 1..1 | uri | "energy" | |
value[x] | 0..1 | CodeableConcept | Value of extension Binding: Image Guided Radiotherapy Energy Unit Value Set (required) | |
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality" | |
value[x] | 0..0 | |||
Documentation for this format |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | C | 0..* | Extension | Image Guided Radiotherapy Modality IGRTEnergyAllowed: Energy is only allowed for X-Ray, Fluorograph, or CT Modalities. |
id | 0..1 | string | Unique id for inter-element referencing | |
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |
extension:modality | S | 1..1 | Extension | Extension |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "modality" | |
value[x] | 0..1 | CodeableConcept | Value of extension Binding: Image Guided Radiotherapy Modality Value Set (required) | |
extension:energy | S | 0..1 | Extension | Extension |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "energy" | |
value[x] | 0..1 | CodeableConcept | Value of extension Binding: Image Guided Radiotherapy Energy Unit Value Set (required) | |
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality" | |
Documentation for this format |
Other representations of profile: CSV, Excel, Schematron
Path | Conformance | ValueSet |
Extension.extension:modality.value[x] | required | ImageGuidedRadiotherapyModalityVS |
Extension.extension:energy.value[x] | required | ImageGuidedRadiotherapyEnergyUnitVS |