This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Orders and Observations Work Group | Maturity Level: 1 | Trial Use | Compartments: Device, Patient, Practitioner, RelatedPerson |
Detailed Descriptions for the elements in the SupplyRequest resource.
SupplyRequest | |
Element Id | SupplyRequest |
Definition | A record of a request for a medication, substance or device used in the healthcare setting. |
Control | 1..1 |
SupplyRequest.identifier | |
Element Id | SupplyRequest.identifier |
Definition | Unique identifier for this supply request. |
Note | This is a business identifer, not a resource identifier (see discussion) |
Control | 0..1 |
Type | Identifier |
Summary | true |
Comments | This is assigned by the requester, and used to refer to this order in other external standards. |
SupplyRequest.status | |
Element Id | SupplyRequest.status |
Definition | Status of the supply request. |
Control | 0..1 |
Terminology Binding | SupplyRequestStatus (Required) |
Type | code |
Is Modifier | true (Reason: This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid) |
Summary | true |
SupplyRequest.category | |
Element Id | SupplyRequest.category |
Definition | Category of supply, e.g. central, non-stock, etc. This is used to support work flows associated with the supply process. |
Control | 0..1 |
Terminology Binding | Supply Type (Example) |
Type | CodeableConcept |
Alternate Names | kind |
Summary | true |
SupplyRequest.priority | |
Element Id | SupplyRequest.priority |
Definition | Indicates how quickly this SupplyRequest should be addressed with respect to other requests. |
Control | 0..1 |
Terminology Binding | RequestPriority (Required) |
Type | code |
Meaning if Missing | If missing, this task should be performed with normal priority |
Summary | true |
SupplyRequest.item[x] | |
Element Id | SupplyRequest.item[x] |
Definition | The item that is requested to be supplied. This is either a link to a resource representing the details of the item or a code that identifies the item from a known list. |
Control | 1..1 |
Terminology Binding | SNOMED CT Supply Item (Example) |
Type | CodeableConcept|Reference(Medication | Substance | Device) |
[x] Note | See Choice of Data Types for further information about how to use [x] |
Summary | true |
Comments | Note that there's a difference between a prescription - an instruction to take a medication, along with a (sometimes) implicit supply, and an explicit request to supply, with no explicit instructions. |
SupplyRequest.quantity | |
Element Id | SupplyRequest.quantity |
Definition | The amount that is being ordered of the indicated item. |
Control | 1..1 |
Type | Quantity |
Summary | true |
SupplyRequest.parameter | |
Element Id | SupplyRequest.parameter |
Definition | Specific parameters for the ordered item. For example, the size of the indicated item. |
Control | 0..* |
SupplyRequest.parameter.code | |
Element Id | SupplyRequest.parameter.code |
Definition | A code or string that identifies the device detail being asserted. |
Control | 0..1 |
Terminology Binding | ParameterCode: |
Type | CodeableConcept |
SupplyRequest.parameter.value[x] | |
Element Id | SupplyRequest.parameter.value[x] |
Definition | The value of the device detail. |
Control | 0..1 |
Type | CodeableConcept|Quantity|Range|boolean |
[x] Note | See Choice of Data Types for further information about how to use [x] |
Comments | Range means device should have a value that falls somewhere within the specified range. |
SupplyRequest.occurrence[x] | |
Element Id | SupplyRequest.occurrence[x] |
Definition | When the request should be fulfilled. |
Control | 0..1 |
Type | dateTime|Period|Timing |
[x] Note | See Choice of Data Types for further information about how to use [x] |
Alternate Names | when; timing |
Summary | true |
SupplyRequest.authoredOn | |
Element Id | SupplyRequest.authoredOn |
Definition | When the request was made. |
Control | 0..1 |
Type | dateTime |
Alternate Names | date; createdOn; signedOn |
Summary | true |
SupplyRequest.requester | |
Element Id | SupplyRequest.requester |
Definition | The device, practitioner, etc. who initiated the request. |
Control | 0..1 |
Type | Reference(Practitioner | PractitionerRole | Organization | Patient | RelatedPerson | Device) |
Alternate Names | author; source |
Summary | true |
SupplyRequest.supplier | |
Element Id | SupplyRequest.supplier |
Definition | Who is intended to fulfill the request. |
Control | 0..* |
Type | Reference(Organization | HealthcareService) |
Alternate Names | performer |
Summary | true |
SupplyRequest.reasonCode | |
Element Id | SupplyRequest.reasonCode |
Definition | The reason why the supply item was requested. |
Control | 0..* |
Terminology Binding | SupplyRequestReason (Example) |
Type | CodeableConcept |
SupplyRequest.reasonReference | |
Element Id | SupplyRequest.reasonReference |
Definition | The reason why the supply item was requested. |
Control | 0..* |
Type | Reference(Condition | Observation | DiagnosticReport | DocumentReference) |
SupplyRequest.deliverFrom | |
Element Id | SupplyRequest.deliverFrom |
Definition | Where the supply is expected to come from. |
Control | 0..1 |
Type | Reference(Organization | Location) |
SupplyRequest.deliverTo | |
Element Id | SupplyRequest.deliverTo |
Definition | Where the supply is destined to go. |
Control | 0..1 |
Type | Reference(Organization | Location | Patient) |