CardX - Cardiac Implantable Electronic Devices
1.0.0-ballot - STU 1 - Ballot International flag

This page is part of the CardX - Cardiac Implantable Electronic Devices (v1.0.0-ballot: STU 1 Ballot 1) based on FHIR (HL7® FHIR® Standard) v5.0.0. No current official version has been published yet. For a full list of available versions, see the Directory of published versions

Artifacts Summary

This page provides a list of the FHIR artifacts defined as part of this implementation guide.

Behavior: Capability Statements

The following artifacts define the specific capabilities that different types of systems are expected to have in order to comply with this implementation guide. Systems conforming to this implementation guide are expected to declare conformance to one or more of the following capability statements.

CardX CIED Connectivity Server Capability Statement

This capability statement describes the requirements for systems that make CIED Connectivity data available.

Structures: Resource Profiles

These define constraints on FHIR resources for systems conforming to this implementation guide.

Device - CIED Monitor Profile

The following data-elements must always be present (Mandatory definition) or must be supported if the data is present in the sending system (Must Support definition). They are presented below in a simple human-readable explanation. Profile specific guidance and examples are provided as well. The Formal Profile Definition below provides the formal summary, definitions, and terminology requirements.

Within IEEE 11073-10103, MDC_IDC_DEV contains the following data elements: MDC_IDC_DEV_TYPE MDC_IDC_DEV_MODEL MDC_IDC_DEV_SERIAL MDC_IDC_DEV_MFG

Device - Cardiovascular Implantable Electronic Device (CIED)

The following data-elements must always be present (Mandatory definition) or must be supported if the data is present in the sending system (Must Support definition). They are presented below in a simple human-readable explanation. Profile specific guidance and examples are provided as well. The Formal Profile Definition below provides the formal summary, definitions, and terminology requirements.

Within IEEE 11073-10103, MDC_IDC_DEV contains the following data elements: MDC_IDC_DEV_TYPE MDC_IDC_DEV_MODEL MDC_IDC_DEV_SERIAL MDC_IDC_DEV_MFG

Observation - CIED Connectivity

Profile of the observation resource to present the most recent connectivity status and associated information for a CIED/Monitor pair.

CIEDs and monitors connect at regular intervals to exchange data ranging from every few minutes to every other week depending on the device/monitor configuration and manufacturer. The connectivity observation profile is a snapshot in time and is not intended to be used to query historical log information that may have been captured by the remote monitoring IoT platform. A single observation will be returned for every CIED/monitor pair.

Patient - CIED Patient Profile

An CIED profile of the Patient resource.

Structures: Extension Definitions

These define constraints on FHIR data types for systems conforming to this implementation guide.

CIED Device Extension

Extension to represent cardiac implantable device(s) which generated the observation.

Terminology: Value Sets

These define sets of codes used by systems conforming to this implementation guide.

CIED Connectivity Status Modifier Value Set

Additional modifiers to connectivity status as calculated by the CIED manufacturer

CIED Connectivity Status Value Set

The overall system connectivity status as calculated by the CIED manufacturer

CIED Monitor Types

The type of CIED monitor

CIED Patient Identifier

Identifiers which can be used to identify CIED patients.

IEEE 11073-10103 Device Type

The type of device as defined by IEEE 11073-10103

IEEE 11073-10103 Session Type

The type of session as defined by IEEE 11073-10103

Terminology: Code Systems

These define new code systems used by systems conforming to this implementation guide.

CIED Connectivity Status Values

Codes system for CIED connectivity and monitor device types

ISO/IEEE-11073-10103

ISO/IEEE-11073-10103 - Implantable Device Cardiac nomenclature.

Example: Example Instances

These are example instances that show what data produced and consumed by systems conforming with this implementation guide might look like.

uc1ACMEICD

An example CIED device for CIED connectivity example 1.

uc1ACMEPatient

An example CIED patient for CIED connectivity example 1.

uc1ConnectivityACME

An example CIED connectivity status for CIED connectivity example 1.

uc2ACMEPacemaker

An example CIED device for CIED connectivity example 2.

uc2ACMEPatient

An example CIED patient for CIED connectivity example 2.

uc2CIEDMonitor

An example CIED monitor for CIED connectivity example 2.

uc2ConnectivityACME

An example CIED connectivity status for CIED connectivity example 2.

uc3ACMEPacemaker

An example CIED device for CIED connectivity example 3.

uc3ACMEPatient

An example CIED patient for CIED connectivity example 3.

uc3CIEDMonitor

An example CIED monitor for CIED connectivity example 3.

uc3ConnectivityACME

An example CIED connectivity status for CIED connectivity example 3.

uc4ACMEPacemaker

An example CIED device for CIED connectivity example 4.

uc4ACMEPatient

An example CIED patient for CIED connectivity example 4.

uc4CIEDMonitor

An example CIED monitor for CIED connectivity example 4.

uc4ConnectivityACME

An example CIED connectivity status for CIED connectivity example 4.

uc5ACMEPacemaker

An example CIED device for CIED connectivity example 5.

uc5ACMEPatient

An example CIED patient for CIED connectivity example 5.

uc5CIEDMonitor

An example CIED monitor for CIED connectivity example 5.

uc5ConnectivityACME

An example CIED connectivity status for CIED connectivity example 5.