This page is part of the CardX - Cardiac Implantable Electronic Devices (v1.0.0-ballot: STU 1 Ballot 1) based on FHIR (HL7® FHIR® Standard) v5.0.0. No current official version has been published yet. For a full list of available versions, see the Directory of published versions
Page standards status: Trial-use | Maturity Level: 2 |
<CapabilityStatement xmlns="http://hl7.org/fhir">
<id value="cied-data-sender"/>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: CapabilityStatement cied-data-sender</b></p><a name="cied-data-sender"> </a><a name="hccied-data-sender"> </a><h2 id="title">CardX CIED Connectivity Server Capability Statement</h2><ul><li>Implementation Guide Version: 1.0.0-ballot </li><li>FHIR Version: 5.0.0 </li><li>Supported Formats: <code>json</code></li><li>Supported Patch Formats: </li><li>Published on: 2025-07-09 </li><li>Published by: HL7 International / Clinical Interoperability Council </li></ul><blockquote class="impl-note"><p><strong>Note to Implementers: FHIR Capabilities</strong></p><p>Any FHIR capability may be 'allowed' by the system unless explicitly marked as 'SHALL NOT'. A few items are marked as MAY in the Implementation Guide to highlight their potential relevance to the use case.</p></blockquote><h2 id="rest">FHIR RESTful Capabilities</h2><div class="panel panel-default"><div class="panel-heading"><h3 id="mode1" class="panel-title">Mode: <code>server</code></h3></div><div class="panel-body"><div><p>A CardX CIED Connectivity Server <strong>SHALL</strong>:</p>
<ol>
<li>Implement the RESTful behavior according to the FHIR specification.</li>
<li>Return the following response classes:
<ul>
<li>(Status 400): invalid parameter</li>
<li>(Status 401): unauthorized request</li>
<li>(Status 403): insufficient scope</li>
<li>(Status 404): unknown resource</li>
<li>(Status 410): deleted resource.</li>
<li>(Status 501): not implemented.</li>
</ul>
</li>
</ol>
</div><div class="lead"><em>Security</em></div><blockquote><div><ol>
<li>See the <a href="https://www.hl7.org/fhir/security.html#general">General Security Considerations</a> section for requirements and recommendations.</li>
<li>A server <strong>SHALL</strong> reject any unauthorized requests by returning an <code>HTTP 401</code> unauthorized response code.</li>
</ol>
</div></blockquote><div class="lead"><em>Summary of System-wide Interactions</em></div></div></div><h3 id="resourcesCap1">Capabilities by Resource/Profile</h3><h4 id="resourcesSummary1">Summary</h4><p>The summary table lists the resources that are part of this configuration, and for each resource it lists:</p><ul><li>The relevant profiles (if any)</li><li>The interactions supported by each resource (<b><span class="bg-info">R</span></b>ead, <b><span class="bg-info">S</span></b>earch, <b><span class="bg-info">U</span></b>pdate, and <b><span class="bg-info">C</span></b>reate, are always shown, while <b><span class="bg-info">VR</span></b>ead, <b><span class="bg-info">P</span></b>atch, <b><span class="bg-info">D</span></b>elete, <b><span class="bg-info">H</span></b>istory on <b><span class="bg-info">I</span></b>nstance, or <b><span class="bg-info">H</span></b>istory on <b><span class="bg-info">T</span></b>ype are only present if at least one of the resources has support for them.</li><li><span>The required, recommended, and some optional search parameters (if any). </span></li><li>The linked resources enabled for <code>_include</code></li><li>The other resources enabled for <code>_revinclude</code></li><li>The operations on the resource (if any)</li></ul><div class="table-responsive"><table class="table table-condensed table-hover"><thead><tr><th><b>Resource Type</b></th><th><b>Profile</b></th><th class="text-center"><b title="GET a resource (read interaction)">R</b></th><th class="text-center"><b title="GET all set of resources of the type (search interaction)">S</b></th><th class="text-center"><b title="PUT a new resource version (update interaction)">U</b></th><th class="text-center"><b title="POST a new resource (create interaction)">C</b></th><th><b title="Required and recommended search parameters">Searches</b></th><th><code><b>_include</b></code></th><th><code><b>_revinclude</b></code></th><th><b>Operations</b></th></tr></thead><tbody><tr><td><a href="#Patient1-1">Patient</a></td><td>Supported Profiles<br/> <a href="StructureDefinition-cied-patient.html">Patient - CIED Patient Profile</a></td><td class="text-center">y</td><td class="text-center">y</td><td class="text-center"/><td class="text-center"/><td>identifier</td><td/><td/><td/></tr><tr><td><a href="#Device1-2">Device</a></td><td>Supported Profiles<br/> <a href="StructureDefinition-cied-device.html">Device - Cardiovascular Implantable Electronic Device (CIED)</a><br/> <a href="StructureDefinition-cied-monitor.html">Device - CIED Monitor Profile</a></td><td class="text-center">y</td><td class="text-center">y</td><td class="text-center"/><td class="text-center"/><td>manufacturer, model, udi-di, type, serial-number</td><td/><td/><td/></tr><tr><td><a href="#Observation1-3">Observation</a></td><td>Supported Profiles<br/> <a href="StructureDefinition-cied-connectivity-status.html">Observation - CIED Connectivity</a></td><td class="text-center">y</td><td class="text-center">y</td><td class="text-center"/><td class="text-center"/><td>subject, code, component-value-concept</td><td/><td/><td/></tr></tbody></table></div><hr/><div class="panel panel-default"><div class="panel-heading"><h4 id="Patient1-1" class="panel-title"><span style="float: right;">Resource Conformance: SHALL </span>Patient</h4></div><div class="panel-body"><div class="container"><div class="row"><div class="col-lg-4"><span class="lead">Core FHIR Resource</span><br/><a href="http://hl7.org/fhir/patient.html">Patient</a></div><div class="col-lg-4"><span class="lead">Reference Policy</span><br/></div><div class="col-lg-4"><span class="lead">Interaction summary</span><br/><ul><li><strong>SHALL</strong> support <code>read</code>, <code>search-type</code>.</li></ul></div></div><p/><div class="row"><div class="col-6"><span class="lead">Supported Profiles</span><p><a href="StructureDefinition-cied-patient.html">Patient - CIED Patient Profile</a></p></div></div><p/><div class="row"><div class="col-lg-7"><span class="lead">Search Parameters</span><table class="table table-condensed table-hover"><thead><tr><th>Conformance</th><th>Parameter</th><th>Type</th><th>Documentation</th></tr></thead><tbody><tr><td><b>SHOULD</b></td><td><a href="http://hl7.org/fhir/patient.html#search">identifier</a></td><td><code>token</code></td><td><div/></td></tr></tbody></table></div><div class="col-lg-5"> </div></div></div></div></div><div class="panel panel-default"><div class="panel-heading"><h4 id="Device1-2" class="panel-title"><span style="float: right;">Resource Conformance: SHALL </span>Device</h4></div><div class="panel-body"><div class="container"><div class="row"><div class="col-lg-4"><span class="lead">Core FHIR Resource</span><br/><a href="http://hl7.org/fhir/device.html">Device</a></div><div class="col-lg-4"><span class="lead">Reference Policy</span><br/></div><div class="col-lg-4"><span class="lead">Interaction summary</span><br/><ul><li><strong>SHALL</strong> support <code>read</code>, <code>search-type</code>.</li></ul></div></div><p/><div class="row"><div class="col-6"><span class="lead">Supported Profiles</span><p><a href="StructureDefinition-cied-device.html">Device - Cardiovascular Implantable Electronic Device (CIED)</a><br/><a href="StructureDefinition-cied-monitor.html">Device - CIED Monitor Profile</a></p></div></div><p/><div class="row"><div class="col-lg-7"><span class="lead">Search Parameters</span><table class="table table-condensed table-hover"><thead><tr><th>Conformance</th><th>Parameter</th><th>Type</th><th>Documentation</th></tr></thead><tbody><tr><td><b>SHOULD</b></td><td><a href="http://hl7.org/fhir/device.html#search">manufacturer</a></td><td><code>string</code></td><td><div/></td></tr><tr><td><b>SHOULD</b></td><td><a href="http://hl7.org/fhir/device.html#search">model</a></td><td><code>string</code></td><td><div/></td></tr><tr><td><b>SHOULD</b></td><td><a href="http://hl7.org/fhir/device.html#search">udi-di</a></td><td><code>string</code></td><td><div/></td></tr><tr><td><b>SHOULD</b></td><td><a href="http://hl7.org/fhir/device.html#search">type</a></td><td><code>token</code></td><td><div/></td></tr><tr><td><b>SHOULD</b></td><td><a href="http://hl7.org/fhir/device.html#search">serial-number</a></td><td><code>string</code></td><td><div/></td></tr></tbody></table></div><div class="col-lg-5"> </div></div></div></div></div><div class="panel panel-default"><div class="panel-heading"><h4 id="Observation1-3" class="panel-title"><span style="float: right;">Resource Conformance: SHALL </span>Observation</h4></div><div class="panel-body"><div class="container"><div class="row"><div class="col-lg-4"><span class="lead">Core FHIR Resource</span><br/><a href="http://hl7.org/fhir/observation.html">Observation</a></div><div class="col-lg-4"><span class="lead">Reference Policy</span><br/></div><div class="col-lg-4"><span class="lead">Interaction summary</span><br/><ul><li><strong>SHALL</strong> support <code>read</code>, <code>search-type</code>.</li></ul></div></div><p/><div class="row"><div class="col-6"><span class="lead">Supported Profiles</span><p><a href="StructureDefinition-cied-connectivity-status.html">Observation - CIED Connectivity</a></p></div></div><p/><div class="row"><div class="col-lg-7"><span class="lead">Search Parameters</span><table class="table table-condensed table-hover"><thead><tr><th>Conformance</th><th>Parameter</th><th>Type</th><th>Documentation</th></tr></thead><tbody><tr><td><b>SHALL</b></td><td><a href="http://hl7.org/fhir/observation.html#search">code</a></td><td><code>token</code></td><td><div/></td></tr><tr><td><b>SHOULD</b></td><td><a href="http://hl7.org/fhir/observation.html#search">subject</a></td><td><code>reference</code></td><td><div/></td></tr><tr><td><b>SHOULD</b></td><td><a href="http://hl7.org/fhir/observation.html#search">component-value-concept</a></td><td><code>token</code></td><td><div/></td></tr></tbody></table></div><div class="col-lg-5"> </div></div></div></div></div></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
<valueCode value="cic"/>
</extension>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
<valueInteger value="2">
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
<valueCanonical
value="http://hl7.org/fhir/uv/cardx-cied/ImplementationGuide/hl7.fhir.uv.cardx-cied"/>
</extension>
</valueInteger>
</extension>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
<valueCode value="trial-use">
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
<valueCanonical
value="http://hl7.org/fhir/uv/cardx-cied/ImplementationGuide/hl7.fhir.uv.cardx-cied"/>
</extension>
</valueCode>
</extension>
<url
value="http://hl7.org/fhir/uv/cardx-cied/CapabilityStatement/cied-data-sender"/>
<version value="1.0.0-ballot"/>
<name value="CIEDConnectivityServerCapabilityStatement"/>
<title value="CardX CIED Connectivity Server Capability Statement"/>
<status value="active"/>
<date value="2025-07-09"/>
<publisher value="HL7 International / Clinical Interoperability Council"/>
<contact>
<name value="HL7 International / Clinical Interoperability Council"/>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/cic"/>
</telecom>
<telecom>
<system value="email"/>
<value value="ciclist@lists.hl7.org"/>
</telecom>
</contact>
<description value="CardX CIED Connectivity Server CapabilityStatement"/>
<jurisdiction>
<coding>
<system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
<code value="001"/>
<display value="World"/>
</coding>
</jurisdiction>
<kind value="requirements"/>
<fhirVersion value="5.0.0"/>
<format value="json"/>
<rest>
<mode value="server"/>
<documentation
value="A CardX CIED Connectivity Server **SHALL**:
1. Implement the RESTful behavior according to the FHIR specification.
1. Return the following response classes:
- (Status 400): invalid parameter
- (Status 401): unauthorized request
- (Status 403): insufficient scope
- (Status 404): unknown resource
- (Status 410): deleted resource.
- (Status 501): not implemented.
"/>
<security>
<description
value="1. See the [General Security Considerations](https://www.hl7.org/fhir/security.html#general) section for requirements and recommendations.
1. A server **SHALL** reject any unauthorized requests by returning an `HTTP 401` unauthorized response code."/>
</security>
<resource>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
<type value="Patient"/>
<supportedProfile
value="http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-patient">🔗
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
</supportedProfile>
<interaction>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
<code value="read"/>
</interaction>
<interaction>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
<code value="search-type"/>
</interaction>
<searchParam>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHOULD"/>
</extension>
<name value="identifier"/>
<definition
value="http://hl7.org/fhir/SearchParameter/Patient-identifier"/>
<type value="token"/>
</searchParam>
</resource>
<resource>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
<type value="Device"/>
<supportedProfile
value="http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-device">🔗
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
</supportedProfile>
<supportedProfile
value="http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-monitor">🔗
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
</supportedProfile>
<interaction>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
<code value="read"/>
</interaction>
<interaction>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
<code value="search-type"/>
</interaction>
<searchParam>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHOULD"/>
</extension>
<name value="manufacturer"/>
<definition
value="http://hl7.org/fhir/SearchParameter/Device-manufacturer"/>
<type value="string"/>
</searchParam>
<searchParam>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHOULD"/>
</extension>
<name value="model"/>
<definition value="http://hl7.org/fhir/SearchParameter/Device-model"/>
<type value="string"/>
</searchParam>
<searchParam>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHOULD"/>
</extension>
<name value="udi-di"/>
<definition
value="http://hl7.org/fhir/SearchParameter/Device-udi-di"/>
<type value="string"/>
</searchParam>
<searchParam>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHOULD"/>
</extension>
<name value="type"/>
<definition value="http://hl7.org/fhir/SearchParameter/Device-type"/>
<type value="token"/>
</searchParam>
<searchParam>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHOULD"/>
</extension>
<name value="serial-number"/>
<definition
value="http://hl7.org/fhir/SearchParameter/Device-serial-number"/>
<type value="string"/>
</searchParam>
</resource>
<resource>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
<type value="Observation"/>
<supportedProfile
value="http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-connectivity-status">🔗
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
</supportedProfile>
<interaction>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
<code value="read"/>
</interaction>
<interaction>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
<code value="search-type"/>
</interaction>
<searchParam>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHOULD"/>
</extension>
<name value="subject"/>
<definition
value="http://hl7.org/fhir/SearchParameter/Observation-subject"/>
<type value="reference"/>
</searchParam>
<searchParam>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHALL"/>
</extension>
<name value="code"/>
<definition
value="http://hl7.org/fhir/SearchParameter/clinical-code"/>
<type value="token"/>
</searchParam>
<searchParam>
<extension
url="http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation">
<valueCode value="SHOULD"/>
</extension>
<name value="component-value-concept"/>
<definition
value="http://hl7.org/fhir/SearchParameter/Observation-component-value-concept"/>
<type value="token"/>
</searchParam>
</resource>
</rest>
</CapabilityStatement>