Structured Data Capture
4.0.0-ballot - STU 4 ballot International flag

This page is part of the Structured Data Capture FHIR IG (v4.0.0-ballot: STU 4 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 3.0.0. For a full list of available versions, see the Directory of published versions

Extension: Enable when expression

Official URL: http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-enableWhenExpression Version: 4.0.0-ballot
Standards status: Trial-use Maturity Level: 4 Computable Name: EnableWhenExpressionExtension
Other Identifiers: OID:2.16.840.1.113883.4.642.40.17.42.22

An expression that returns a boolean value for whether to enable the item. If the expression does not resolve to a boolean, it is considered an error in the design of the Questionnaire. Form renderer behavior is undefined. Some tools may attempt to force the value to be a boolean (e.g. is it a non-empty collection, non-null, non-zero - if so, then true). Systems SHOULD present a warning to the user if a non-boolean valued expression result does not trigger an all-out error.

Context of Use

This extension may be used on the following element(s):

  • Element ID Questionnaire.item
  • Element ID ElementDefinition

Additional details on the use of this extension can be found on the Form Behavior page.

Usage info

Usage:

Formal Views of Extension Content

Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.

This structure is derived from Extension

Summary

Simple Extension of type Expression: An expression that returns a boolean value for whether to enable the item. If the expression does not resolve to a boolean, it is considered an error in the design of the Questionnaire. Form renderer behavior is undefined. Some tools may attempt to force the value to be a boolean (e.g. is it a non-empty collection, non-null, non-zero - if so, then true). Systems SHOULD present a warning to the user if a non-boolean valued expression result does not trigger an all-out error.

Maturity: 4

This structure is derived from Extension

NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension 0..1 Extension Expression for when to enable the item
... extension 0..0
... url 1..1 uri "http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-enableWhenExpression"
... value[x] C 0..1 Expression Value of extension
sdc-inv1: FHIR query language not allowed.

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension 0..1 Extension Expression for when to enable the item
... id 0..1 string Unique id for inter-element referencing
... extension 0..0
... url 1..1 uri "http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-enableWhenExpression"

doco Documentation for this format

This structure is derived from Extension

Summary

Simple Extension of type Expression: An expression that returns a boolean value for whether to enable the item. If the expression does not resolve to a boolean, it is considered an error in the design of the Questionnaire. Form renderer behavior is undefined. Some tools may attempt to force the value to be a boolean (e.g. is it a non-empty collection, non-null, non-zero - if so, then true). Systems SHOULD present a warning to the user if a non-boolean valued expression result does not trigger an all-out error.

Maturity: 4

Differential View

This structure is derived from Extension

NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension 0..1 Extension Expression for when to enable the item
... extension 0..0
... url 1..1 uri "http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-enableWhenExpression"
... value[x] C 0..1 Expression Value of extension
sdc-inv1: FHIR query language not allowed.

doco Documentation for this format

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension 0..1 Extension Expression for when to enable the item
... id 0..1 string Unique id for inter-element referencing
... extension 0..0
... url 1..1 uri "http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaire-enableWhenExpression"

doco Documentation for this format

 

Other representations of profile: CSV, Excel, Schematron

Constraints

IdGradePath(s)DetailsRequirements
sdc-inv1errorExtension.value[x]FHIR query language not allowed.
: language!='application/x-fhir-query'