This page is part of the International Patient Summary Implementation Guide (v0.1.0: STU 1 Ballot 1) based on FHIR R3. The current version which supercedes this version is 1.1.0. For a full list of available versions, see the Directory of published versions
SD.20 StructureDefinition-observation-member-laboratory-uv-ips
This profile constrains the Observation resource to represent a sub-observation, member of an “organizer” observation, in the “Laboratory results” entry of a patient summary
Conformance resource variables defined here
SD.20.1 Formal Views of Profile Content
Description of Profiles, Differentials, and Snapshots.
The official URL for this profile is: http://hl7.org/fhir/uv/ips/StructureDefinition/observation-member-laboratory-uv-ips
Published on Fri Mar 09 00:00:00 AEDT 2018 as a draft by HL7 International.
This profile builds on Observation
Differential View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | simple observation | |||
basedOn | ..0 | |||
status | Fixed Value: final | |||
category | S | 1..1 | CodeableConcept-uv-ips | Binding: ObservationSubCategories (required) |
code | S | CodeableConcept-uv-ips | Binding: IPSLabResultsObservation (extensible) | |
subject | S | 1.. | Reference(Patient) | |
identifier | ..0 | |||
effectiveDateTime | S | 1.. | dateTime | |
performer | ..1 | Reference(Practitioner | Patient | Organization (laboratory)) | ||
identifier | ..0 | |||
value[x] | 1.. | string, Range, Ratio, Attachment, dateTime, CodeableConcept-uv-ips, quantity-uv-ips | Binding: IPSLabResultsCodedValues (extensible) | |
dataAbsentReason | ..0 | |||
interpretation | CodeableConcept-uv-ips | |||
bodySite | ..0 | |||
specimen | Reference(Specimen) | |||
identifier | ..0 | |||
device | ..0 | |||
related | ..0 | |||
component | ..0 | |||
Documentation for this format |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | I | 0..* | simple observation dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-1: If the resource is contained in another resource, it SHALL NOT contain any narrative dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource obs-7: If code is the same as a component code then the value element associated with the code SHALL NOT be present obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present | |
id | ΣI | 0..1 | id | Logical id of this artifact ele-1: All FHIR elements must have a @value or children |
meta | ΣI | 0..1 | Meta | Metadata about the resource ele-1: All FHIR elements must have a @value or children |
implicitRules | ?!ΣI | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
language | I | 0..1 | code | Language of the resource content Binding: Common Languages (extensible) ele-1: All FHIR elements must have a @value or children |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation ele-1: All FHIR elements must have a @value or children |
contained | 0..* | Resource | Contained, inline Resources | |
identifier | ΣI | 0..* | Identifier | Business Identifier for observation ele-1: All FHIR elements must have a @value or children |
status | ?!ΣI | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) ele-1: All FHIR elements must have a @value or children Fixed Value: final |
category | SI | 1..1 | CodeableConcept-uv-ips | Concept - reference to a terminology or just text Binding: ObservationSubCategories (required) ele-1: All FHIR elements must have a @value or children |
code | SΣI | 0..* | CodeableConcept-uv-ips | Concept - reference to a terminology or just text Binding: IPSLabResultsObservation (extensible) ele-1: All FHIR elements must have a @value or children |
subject | SΣI | 1..1 | Reference(Patient) | Who and/or what this is about ele-1: All FHIR elements must have a @value or children ref-1: SHALL have a contained resource if a local reference is provided |
id | I | 0..1 | string | xml:id (or equivalent in JSON) ele-1: All FHIR elements must have a @value or children |
reference | ΣI | 0..1 | string | Literal reference, Relative, internal or absolute URL ele-1: All FHIR elements must have a @value or children |
display | ΣI | 0..1 | string | Text alternative for the resource ele-1: All FHIR elements must have a @value or children |
context | I | 0..1 | Reference(Encounter | EpisodeOfCare) | Healthcare event during which this observation is made ele-1: All FHIR elements must have a @value or children ref-1: SHALL have a contained resource if a local reference is provided |
effectiveDateTime | SΣI | 1..1 | dateTime | Clinically relevant time/time-period for observation ele-1: All FHIR elements must have a @value or children |
issued | ΣI | 0..1 | instant | Date/Time this was made available ele-1: All FHIR elements must have a @value or children |
performer | ΣI | 0..1 | Reference(Practitioner | Patient | Organization (laboratory)) | Who is responsible for the observation ele-1: All FHIR elements must have a @value or children ref-1: SHALL have a contained resource if a local reference is provided |
id | I | 0..1 | string | xml:id (or equivalent in JSON) ele-1: All FHIR elements must have a @value or children |
reference | ΣI | 0..1 | string | Literal reference, Relative, internal or absolute URL ele-1: All FHIR elements must have a @value or children |
display | ΣI | 0..1 | string | Text alternative for the resource ele-1: All FHIR elements must have a @value or children |
value[x] | ΣI | 1..1 | string, Range, Ratio, Attachment, dateTime, CodeableConcept-uv-ips, quantity-uv-ips | Actual result Binding: IPSLabResultsCodedValues (extensible) ele-1: All FHIR elements must have a @value or children qty-3: If a code for the unit is present, the system SHALL also be present |
interpretation | I | 0..* | CodeableConcept-uv-ips | Concept - reference to a terminology or just text Binding: Observation Interpretation Codes (extensible) ele-1: All FHIR elements must have a @value or children |
comment | I | 0..1 | string | Comments about result ele-1: All FHIR elements must have a @value or children |
method | I | 0..1 | CodeableConcept | How it was done Binding: Observation Methods (example) ele-1: All FHIR elements must have a @value or children |
specimen | I | 0..1 | Reference(Specimen) | Specimen used for this observation ele-1: All FHIR elements must have a @value or children ref-1: SHALL have a contained resource if a local reference is provided |
id | I | 0..1 | string | xml:id (or equivalent in JSON) ele-1: All FHIR elements must have a @value or children |
reference | ΣI | 0..1 | string | Literal reference, Relative, internal or absolute URL ele-1: All FHIR elements must have a @value or children |
display | ΣI | 0..1 | string | Text alternative for the resource ele-1: All FHIR elements must have a @value or children |
referenceRange | I | 0..* | BackboneElement | Provides guide for interpretation ele-1: All FHIR elements must have a @value or children obs-3: Must have at least a low or a high or text |
id | I | 0..1 | string | xml:id (or equivalent in JSON) ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?!ΣI | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
low | I | 0..1 | SimpleQuantity | Low Range, if relevant ele-1: All FHIR elements must have a @value or children qty-3: If a code for the unit is present, the system SHALL also be present sqty-1: The comparator is not used on a SimpleQuantity |
high | I | 0..1 | SimpleQuantity | High Range, if relevant ele-1: All FHIR elements must have a @value or children qty-3: If a code for the unit is present, the system SHALL also be present sqty-1: The comparator is not used on a SimpleQuantity |
type | I | 1..1 | CodeableConcept | Reference range qualifier Binding: Observation Reference Range Meaning Codes (extensible) ele-1: All FHIR elements must have a @value or children |
text | I | 0..1 | string | Text based reference range in an observation ele-1: All FHIR elements must have a @value or children |
Documentation for this format |