 0 Table of Contents |
  1 Home |
  2 Background |
  3 Architecture |
  4 Mapping |
  5 Example |
  6 Artifacts Summary |
   6.1 Body Structure - DICOM SR Finding Site Mapping |
   6.2 Body Structure - DICOM SR Observation Tracking Identifier Mapping |
   6.3 Device - DICOM General Equipment |
   6.4 Device - DICOM SR TID 4019 Algorithm Identification Mapping |
   6.5 Imaging Selection - DICOM SR 2D Image Region Mapping |
   6.6 Imaging Selection - DICOM SR Base Imaging Selection |
   6.7 Imaging Selection - DICOM SR Illustration Of ROI Mapping |
   6.8 Imaging Selection - DICOM SR Image 3D Region Mapping |
   6.9 Imaging Selection - DICOM SR Image Volume Surface Mapping |
   6.10 Imaging Selection - DICOM SR Real World Value Map |
   6.11 Imaging Selection - DICOM SR Referenced Segment Mapping |
   6.12 Imaging Selection - DICOM SR Referenced Segmentation Frame Mapping |
   6.13 Imaging Selection - DICOM SR Region In Space |
   6.14 Imaging Selection - DICOM SR Visual Explanation Mapping |
   6.15 Observation - DICOM SR Derived Imaging Measurement Mapping to Observation |
   6.16 Observation - DICOM SR Imaging Measurement Group Mapping |
   6.17 Observation - DICOM SR Imaging Measurement Mapping to Observation |
   6.18 Observation - DICOM SR Imaging Observation |
   6.19 Observation - DICOM SR Imaging Qualitative Evaluation Mapping to Observation |
   6.20 Identifiers - DICOM Identifier Type |
   6.21 Value Types -- DICOM SR Content Item Value Types |
   6.22 ConceptMap - DICOM Derived Imaging Measurement to FHIR Mapping |
   6.23 ConceptMap - DICOM Document IE to FHIR Mapping |
   6.24 ConceptMap - DICOM Imaging Measurement Group to FHIR Mapping |
   6.25 ConceptMap - DICOM Imaging Measurement to FHIR Mapping |
   6.26 ConceptMap - DICOM Imaging Measurements Container to FHIR Mapping |
   6.27 ConceptMap - DICOM Imaging Qualitative Evaluation to FHIR Mapping |
   6.28 ConceptMap - DICOM SR Measurement Report to FHIR Mapping |
   6.29 Example-BodyStructure-FindingSite |
   6.30 Example-BodyStructure-TrackingIdentifiers |
   6.31 Example-Device-AlgorithmIdentification |
   6.32 Example-Device-GeneralEquipment |
   6.33 Example-DiagnosticReport-DICOMSRMeasurementReport |
   6.34 Example-ImagingSelection-IllustrationOfROI |
   6.35 Example-ImagingSelection-ImageRegion2D |
   6.36 Example-ImagingSelection-ImageRegion3D |
   6.37 Example-ImagingSelection-RealWorldValueMap |
   6.38 Example-ImagingSelection-ReferencedSegment |
   6.39 Example-ImagingSelection-ReferencedSegmentationFrame |
   6.40 Example-ImagingSelection-RegionInSpace |
   6.41 Example-ImagingSelection-VisualExplanation |
   6.42 Example-ImagingSelection-VolumeSurface |
   6.43 Example-ImagingStudy |
   6.44 Example-Observation-DerivedImagingMeasurement |
   6.45 Example-Observation-ImagingMeasurement-001 |
   6.46 Example-Observation-ImagingMeasurement-002 |
   6.47 Example-Observation-ImagingMeasurement-003 |
   6.48 Example-Observation-ImagingMeasurementGroup |
   6.49 Example-Observation-ImagingObservation |
   6.50 Example-Observation-ImagingQualitativeEvaluation-001 |
   6.51 Example-Observation-ImagingQualitativeEvaluation-002 |
   6.52 Example-Patient |
   6.53 Example-Practitioner |
   6.54 Example-ServiceRequest |