0 Table of Contents |
1 Home |
2 Background |
3 Architecture |
4 Mapping |
5 Example |
6 Artifacts Summary |
6.1 Body Structure - DICOM SR Finding Site Mapping |
6.2 Body Structure - DICOM SR Observation Tracking Identifier Mapping |
6.3 Device - DICOM General Equipment |
6.4 Device - DICOM SR TID 4019 Algorithm Identification Mapping |
6.5 Imaging Selection - DICOM SR 2D Image Region Mapping |
6.6 Imaging Selection - DICOM SR Base Imaging Selection |
6.7 Imaging Selection - DICOM SR Illustration Of ROI Mapping |
6.8 Imaging Selection - DICOM SR Image 3D Region Mapping |
6.9 Imaging Selection - DICOM SR Image Volume Surface Mapping |
6.10 Imaging Selection - DICOM SR Real World Value Map |
6.11 Imaging Selection - DICOM SR Referenced Segment Mapping |
6.12 Imaging Selection - DICOM SR Referenced Segmentation Frame Mapping |
6.13 Imaging Selection - DICOM SR Region In Space |
6.14 Imaging Selection - DICOM SR Visual Explanation Mapping |
6.15 Observation - DICOM SR Derived Imaging Measurement Mapping to Observation |
6.16 Observation - DICOM SR Imaging Measurement Group Mapping |
6.17 Observation - DICOM SR Imaging Measurement Mapping to Observation |
6.18 Observation - DICOM SR Imaging Observation |
6.19 Observation - DICOM SR Imaging Qualitative Evaluation Mapping to Observation |
6.20 Identifiers - DICOM Identifier Type |
6.21 Value Types -- DICOM SR Content Item Value Types |
6.22 ConceptMap - DICOM Derived Imaging Measurement to FHIR Mapping |
6.23 ConceptMap - DICOM Document IE to FHIR Mapping |
6.24 ConceptMap - DICOM Imaging Measurement Group to FHIR Mapping |
6.25 ConceptMap - DICOM Imaging Measurement to FHIR Mapping |
6.26 ConceptMap - DICOM Imaging Measurements Container to FHIR Mapping |
6.27 ConceptMap - DICOM Imaging Qualitative Evaluation to FHIR Mapping |
6.28 ConceptMap - DICOM SR Measurement Report to FHIR Mapping |
6.29 Example-BodyStructure-FindingSite |
6.30 Example-BodyStructure-TrackingIdentifiers |
6.31 Example-Device-AlgorithmIdentification |
6.32 Example-Device-GeneralEquipment |
6.33 Example-DiagnosticReport-DICOMSRMeasurementReport |
6.34 Example-ImagingSelection-IllustrationOfROI |
6.35 Example-ImagingSelection-ImageRegion2D |
6.36 Example-ImagingSelection-ImageRegion3D |
6.37 Example-ImagingSelection-RealWorldValueMap |
6.38 Example-ImagingSelection-ReferencedSegment |
6.39 Example-ImagingSelection-ReferencedSegmentationFrame |
6.40 Example-ImagingSelection-RegionInSpace |
6.41 Example-ImagingSelection-VisualExplanation |
6.42 Example-ImagingSelection-VolumeSurface |
6.43 Example-ImagingStudy |
6.44 Example-Observation-DerivedImagingMeasurement |
6.45 Example-Observation-ImagingMeasurement-001 |
6.46 Example-Observation-ImagingMeasurement-002 |
6.47 Example-Observation-ImagingMeasurement-003 |
6.48 Example-Observation-ImagingMeasurementGroup |
6.49 Example-Observation-ImagingObservation |
6.50 Example-Observation-ImagingQualitativeEvaluation-001 |
6.51 Example-Observation-ImagingQualitativeEvaluation-002 |
6.52 Example-Patient |
6.53 Example-Practitioner |
6.54 Example-ServiceRequest |