DICOM® SR to FHIR Resource Mapping IG
1.0.0-ballot - STU1 Ballot International flag

This page is part of the DICOM® SR to FHIR Resource Mapping IG (v1.0.0-ballot: STU1 Ballot 1) based on FHIR (HL7® FHIR® Standard) v5.0.0. . For a full list of available versions, see the Directory of published versions

: Example-Observation-ImagingMeasurement-002 - JSON Representation

Raw json | Download


{
  "resourceType" : "Observation",
  "id" : "imaging-measurement-002",
  "meta" : {
    "profile" : [
      🔗 "http://hl7.org/fhir/uv/dicom-sr/StructureDefinition/imaging-measurement"
    ]
  },
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Observation imaging-measurement-002</b></p><a name=\"imaging-measurement-002\"> </a><a name=\"hcimaging-measurement-002\"> </a><a name=\"imaging-measurement-002-en-US\"> </a><p><b>basedOn</b>: <a href=\"ServiceRequest-measurement-report-service-request.html\">ServiceRequest: identifier = Accession ID: ACSN-235813; status = active; intent = order</a></p><p><b>partOf</b>: <a href=\"ImagingStudy-measurement-report-imaging-study.html\">ImagingStudy: identifier = urn:dicom:uid#DICOM Unique Id#urn:oid:1.2.840.113747.20080222.83311413144566317081790268995; status = available</a></p><p><b>status</b>: Final</p><p><b>category</b>: <span title=\"Codes:{http://dicom.nema.org/resources/ontology/DCM 125007}\">Measurement Group</span></p><p><b>code</b>: <span title=\"Codes:{http://snomed.info/sct 81827009}\">Diameter</span></p><p><b>subject</b>: <a href=\"Patient-measurement-report-patient.html\">Anonymous Patient (no stated gender), DoB Unknown ( Medical Record Number: PID-12345)</a></p><p><b>focus</b>: </p><ul><li><a href=\"ImagingSelection-measurement-report-referenced-segment.html\">ImagingSelection Referenced Segment</a></li><li><a href=\"BodyStructure-measurement-report-tracking-identifier.html\">BodyStructure: identifier = Tracking Identifier: Nodule 1,Tracking Unique Identifier: DICOM Unique Id#urn:oid:1.2.840.113747.20080222.83311413144566317081790268995.100</a></li></ul><p><b>effective</b>: 2024-07-24 08:23:42+0000</p><p><b>issued</b>: 2024-07-24 08:23:42+0000</p><p><b>performer</b>: <a href=\"Practitioner-measurement-report-practitioner.html\">Practitioner EXAMPLE RADIOLOGIST </a></p><p><b>value</b>: 6705.54990898997 millimeter<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemm = 'mm')</span></p><p><b>bodyStructure</b>: <a href=\"BodyStructure-measurement-report-finding-site.html\">BodyStructure</a></p><p><b>device</b>: <a href=\"Device-measurement-report-algorithm.html\">Device: displayName = pylidc</a></p></div>"
  },
  "basedOn" : [
    {
      🔗 "reference" : "ServiceRequest/measurement-report-service-request"
    }
  ],
  "partOf" : [
    {
      🔗 "reference" : "ImagingStudy/measurement-report-imaging-study"
    }
  ],
  "status" : "final",
  "category" : [
    {
      "coding" : [
        {
          "system" : "http://dicom.nema.org/resources/ontology/DCM",
          "code" : "125007",
          "display" : "Measurement Group"
        }
      ]
    }
  ],
  "code" : {
    "coding" : [
      {
        "system" : "http://snomed.info/sct",
        "code" : "81827009",
        "display" : "Diameter"
      }
    ]
  },
  "subject" : {
    🔗 "reference" : "Patient/measurement-report-patient"
  },
  "focus" : [
    {
      🔗 "reference" : "ImagingSelection/measurement-report-referenced-segment"
    },
    {
      🔗 "reference" : "BodyStructure/measurement-report-tracking-identifier"
    }
  ],
  "effectiveDateTime" : "2024-07-24T08:23:42+00:00",
  "issued" : "2024-07-24T08:23:42+00:00",
  "performer" : [
    {
      🔗 "reference" : "Practitioner/measurement-report-practitioner"
    }
  ],
  "valueQuantity" : {
    "value" : 6705.54990898997,
    "unit" : "millimeter",
    "system" : "http://unitsofmeasure.org",
    "code" : "mm"
  },
  "bodyStructure" : {
    🔗 "reference" : "BodyStructure/measurement-report-finding-site"
  },
  "device" : {
    🔗 "reference" : "Device/measurement-report-algorithm"
  }
}