This page is part of the DICOM® SR to FHIR Resource Mapping IG (v1.0.0-ballot: STU1 Ballot 1) based on FHIR (HL7® FHIR® Standard) v5.0.0. . For a full list of available versions, see the Directory of published versions
Active as of 2024-08-09 |
<ConceptMap xmlns="http://hl7.org/fhir">
<id value="dicom-document-ie-to-fhir"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ConceptMap dicom-document-ie-to-fhir</b></p><a name="dicom-document-ie-to-fhir"> </a><a name="hcdicom-document-ie-to-fhir"> </a><a name="dicom-document-ie-to-fhir-en-US"> </a><p>Mapping from DICOM-Document to <a href="http://hl7.org/fhir/R5/bundle.html">Bundle</a></p><p>ACTIVE. Published on 2024-08-09 16:26:36+0000 by HL7 International / Imaging Integration (<a href="http://www.hl7.org/Special/committees/imagemgt">http://www.hl7.org/Special/com...</a>, HL7 International / Imaging Integration: <a href="http://www.hl7.org/Special/committees/imagemgt">http://www.hl7.org/Special/com...</a>, Jonathan Whitby: <a href="mailto:jonathan.whitby@mi.medical.canon">jonathan.whitby@mi.medical.canon</a>, <a href="http://www.hl7.org/Special/committees/imagemgt">http://www.hl7.org/Special/com...</a>, Christopher Lindop: <a href="mailto:Christopher.Lindop@ge.com">Christopher.Lindop@ge.com</a>, <a href="http://www.hl7.org/Special/committees/imagemgt">http://www.hl7.org/Special/com...</a>). </p><div><p>Mapping between DICOM® Document IE and FHIR Resources</p>
</div><br/><p><b>Group 1 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class="grid"><tr><td colspan="4"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan="2"><b>Target Concept Details</b></td><td><b>Comment</b></td><td colspan="2"><b>Properties</b></td></tr><tr><td colspan="2"><b>Codes</b> from </td><td><b>DICOMConceptNameCodeSequence</b></td><td><b>OverserverType</b></td><td/><td colspan="2"><b>Codes</b> from </td><td/><td><b>macro-map</b></td><td><b>content-map</b></td></tr><tr><td style="border-right-width: 0px; border-bottom-style: none">DICOM.SR.Document.General</td><td style="border-left-width: 0px">Document General Module</td><td colspan="4" style="background-color: #efefef">(not mapped)</td></tr><tr><td style="border-right-width: 0px">DICOM.PreliminaryFlag</td><td style="border-left-width: 0px">Preliminary Flag (0040,A496)</td><td/><td/><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td style="border-right-width: 0px">status</td><td style="border-left-width: 0px">status</td><td>DICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'.</td><td>todo</td><td>todo</td></tr><tr><td style="border-right-width: 0px">DICOM.ParticipantSequence-Performer</td><td style="border-left-width: 0px">Participant Sequence (0040,A07A) -- PSN</td><td/><td>PSN</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td style="border-right-width: 0px">performer</td><td style="border-left-width: 0px">performer</td><td/><td>todo</td><td>todo</td></tr><tr><td style="border-right-width: 0px">DICOM.ParticipantSequence-Device</td><td style="border-left-width: 0px">Participant Sequence (0040,A07A) -- DEV</td><td/><td>DEV</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td style="border-right-width: 0px">Device[1]</td><td style="border-left-width: 0px">Device[1]</td><td>If this device matches the Equipment IE device an additional device resource does not need to be created.</td><td>todo</td><td>todo</td></tr><tr><td style="border-right-width: 0px">DICOM.ContentSequence.ImagingMeasurements</td><td style="border-left-width: 0px">Content Sequence (0040,A730) -- Imaging Measurements</td><td/><td/><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#source-is-narrower-than-target" title="source-is-narrower-than-target">is narrower than</a></td><td style="border-right-width: 0px">Observation[1]</td><td style="border-left-width: 0px">Observation[1]</td><td/><td>todo</td><td>todo</td></tr></table></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
<valueCode value="ii"/>
</extension>
<url
value="http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-document-ie-to-fhir"/>
<identifier>
<system value="urn:ietf:rfc:3986"/>
<value value="urn:oid:2.16.840.1.113883.4.642.40.39.18.2"/>
</identifier>
<version value="1.0.0-ballot"/>
<name value="DICOMDocumentIEToFHIRMapping"/>
<title value="ConceptMap - DICOM Document IE to FHIR Mapping"/>
<status value="active"/>
<experimental value="false"/>
<date value="2024-08-09T16:26:36+00:00"/>
<publisher value="HL7 International / Imaging Integration"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/imagemgt"/>
</telecom>
</contact>
<contact>
<name value="HL7 International / Imaging Integration"/>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/imagemgt"/>
</telecom>
</contact>
<contact>
<name value="Jonathan Whitby"/>
<telecom>
<system value="email"/>
<value value="jonathan.whitby@mi.medical.canon"/>
</telecom>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/imagemgt"/>
</telecom>
</contact>
<contact>
<name value="Christopher Lindop"/>
<telecom>
<system value="email"/>
<value value="Christopher.Lindop@ge.com"/>
</telecom>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/imagemgt"/>
</telecom>
</contact>
<description value="Mapping between DICOM® Document IE and FHIR Resources"/>
<jurisdiction>
<coding>
<system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
<code value="001"/>
</coding>
</jurisdiction>
<property>
<code value="macro-map"/>
<type value="string"/>
</property>
<property>
<code value="content-map"/>
<type value="string"/>
</property>
<additionalAttribute>
<code value="OverserverType"/>
<uri
value="https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.2.4.html#table_C.17-3b"/>
<description value="DICOM.ParticipantSequence.ObserverType"/>
<type value="code"/>
</additionalAttribute>
<additionalAttribute>
<code value="DICOMConceptNameCodeSequence"/>
<uri
value="https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.3.3.html#table_C.17-5"/>
<description value="DICOM Concept Name Code Sequence (0040,A043)"/>
<type value="Coding"/>
</additionalAttribute>
<sourceScopeUri value="DICOM-Document"/>
<targetScopeUri value="Bundle"/>
<group>
<element>
<code value="DICOM.SR.Document.General"/>
<display value="Document General Module"/>
<noMap value="true"/>
</element>
<element>
<code value="DICOM.PreliminaryFlag"/>
<display value="Preliminary Flag (0040,A496)"/>
<target>
<code value="status"/>
<display value="status"/>
<relationship value="equivalent"/>
<comment
value="DICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'."/>
</target>
</element>
<element>
<code value="DICOM.ParticipantSequence-Performer"/>
<display value="Participant Sequence (0040,A07A) -- PSN"/>
<target>
<code value="performer"/>
<display value="performer"/>
<relationship value="equivalent"/>
<property>
<code value="macro-map"/>
<valueString value="identified-person-or-device"/>
</property>
<dependsOn>
<attribute value="OverserverType"/>
<valueCode value="PSN"/>
</dependsOn>
</target>
</element>
<element>
<code value="DICOM.ParticipantSequence-Device"/>
<display value="Participant Sequence (0040,A07A) -- DEV"/>
<target>
<code value="Device[1]"/>
<display value="Device[1]"/>
<relationship value="equivalent"/>
<comment
value="If this device matches the Equipment IE device an additional device resource does not need to be created."/>
<property>
<code value="macro-map"/>
<valueString value="identified-person-or-device"/>
</property>
<dependsOn>
<attribute value="OverserverType"/>
<valueCode value="DEV"/>
</dependsOn>
</target>
</element>
<element>
<code value="DICOM.ContentSequence.ImagingMeasurements"/>
<display value="Content Sequence (0040,A730) -- Imaging Measurements"/>
<target>
<code value="Observation[1]"/>
<display value="Observation[1]"/>
<relationship value="source-is-narrower-than-target"/>
<property>
<code value="content-map"/>
<valueString value="dicom-imaging-measurement-group"/>
</property>
<dependsOn>
<attribute value="DICOMConceptNameCodeSequence"/>
<valueCoding>
<system value="http://dicom.nema.org/resources/ontology/DCM"/>
<code value="126010"/>
<display value="Imaging Measurements"/>
</valueCoding>
</dependsOn>
</target>
</element>
</group>
</ConceptMap>