This page is part of the DICOM® SR to FHIR Resource Mapping IG (v1.0.0-ballot: STU1 Ballot 1) based on FHIR (HL7® FHIR® Standard) v5.0.0. . For a full list of available versions, see the Directory of published versions
Active as of 2024-08-09 |
{
"resourceType" : "ConceptMap",
"id" : "dicom-derived-imaging-measurement-to-fhir",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ConceptMap dicom-derived-imaging-measurement-to-fhir</b></p><a name=\"dicom-derived-imaging-measurement-to-fhir\"> </a><a name=\"hcdicom-derived-imaging-measurement-to-fhir\"> </a><a name=\"dicom-derived-imaging-measurement-to-fhir-en-US\"> </a><p>Mapping from DICOM-Imaging-Measurement to <a href=\"http://hl7.org/fhir/R5/observation.html\">Observation</a></p><p>ACTIVE. Published on 2024-08-09 16:26:36+0000 by HL7 International / Imaging Integration (<a href=\"http://www.hl7.org/Special/committees/imagemgt\">http://www.hl7.org/Special/com...</a>, HL7 International / Imaging Integration: <a href=\"http://www.hl7.org/Special/committees/imagemgt\">http://www.hl7.org/Special/com...</a>, Jonathan Whitby: <a href=\"mailto:jonathan.whitby@mi.medical.canon\">jonathan.whitby@mi.medical.canon</a>, <a href=\"http://www.hl7.org/Special/committees/imagemgt\">http://www.hl7.org/Special/com...</a>, Christopher Lindop: <a href=\"mailto:Christopher.Lindop@ge.com\">Christopher.Lindop@ge.com</a>, <a href=\"http://www.hl7.org/Special/committees/imagemgt\">http://www.hl7.org/Special/com...</a>). </p><div><p>Mapping between DICOM® Derived Imaging Measurement and FHIR Resources</p>\n</div><br/><p><b>Group 1 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"3\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td><b>ValueType</b></td><td/><td colspan=\"2\"><b>Codes</b> from </td></tr><tr><td style=\"border-right-width: 0px\">CID7465</td><td style=\"border-left-width: 0px\">Measurement Derived From Multiple ROI Measurements</td><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">valueQuantity</td><td style=\"border-left-width: 0px\">DerivedImagingMeasurement.valueQuantity</td></tr></table><hr/><p><b>Group 2 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>TID4019 (Algorithm Identification)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>device (DerivedImagingMeasurement.device)</td><td>Content from the Algorithm Identification template will be used to create a FHIR AlgorithmIdentification Device.</td></tr></table><hr/><p><b>Group 3 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"2\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td><b>Comment</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td/><td colspan=\"2\"><b>Codes</b> from </td><td/></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">125007</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Measurement Group</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingMeasurementGroup</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup</td><td>Measurement Group children of a derived imaging measurement content item are mapped to new ImagingMeasurementGroup observations.</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">derivedFrom</td><td style=\"border-left-width: 0px\">DerivedImagingMeasurement.derivedFrom</td><td/></tr></table></div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "ii"
}
],
"url" : "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-derived-imaging-measurement-to-fhir",
"identifier" : [
{
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.4.642.40.39.18.1"
}
],
"version" : "1.0.0-ballot",
"name" : "DICOMDerivedImagingMeasurementToFHIRMapping",
"title" : "ConceptMap - DICOM Derived Imaging Measurement to FHIR Mapping",
"status" : "active",
"experimental" : false,
"date" : "2024-08-09T16:26:36+00:00",
"publisher" : "HL7 International / Imaging Integration",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name" : "HL7 International / Imaging Integration",
"telecom" : [
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name" : "Jonathan Whitby",
"telecom" : [
{
"system" : "email",
"value" : "jonathan.whitby@mi.medical.canon"
},
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name" : "Christopher Lindop",
"telecom" : [
{
"system" : "email",
"value" : "Christopher.Lindop@ge.com"
},
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/imagemgt"
}
]
}
],
"description" : "Mapping between DICOM® Derived Imaging Measurement and FHIR Resources",
"jurisdiction" : [
{
"coding" : [
{
"system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code" : "001"
}
]
}
],
"additionalAttribute" : [
{
"code" : "IdentifierType",
"uri" : "http://dicom.nema.org/resources/ontology/DCM",
"description" : "DICOM Controlled Terminology",
"type" : "Coding"
},
{
"code" : "ValueType",
"uri" : "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type",
"description" : "DICOM Value Type",
"type" : "Coding"
}
],
"sourceScopeUri" : "DICOM-Imaging-Measurement",
"targetScopeUri" : "Observation",
"group" : [
{
"element" : [
{
"code" : "CID7465",
"display" : "Measurement Derived From Multiple ROI Measurements",
"target" : [
{
"code" : "valueQuantity",
"display" : "DerivedImagingMeasurement.valueQuantity",
"relationship" : "equivalent",
"dependsOn" : [
{
"attribute" : "ValueType",
"valueCoding" : {
"system" : "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type",
"code" : "num"
}
}
]
}
]
}
]
},
{
"element" : [
{
"code" : "TID4019",
"display" : "Algorithm Identification",
"target" : [
{
"code" : "device",
"display" : "DerivedImagingMeasurement.device",
"relationship" : "equivalent",
"comment" : "Content from the Algorithm Identification template will be used to create a FHIR AlgorithmIdentification Device."
}
]
}
]
},
{
"element" : [
{
"code" : "125007",
"display" : "Measurement Group",
"target" : [
{
"code" : "ImagingMeasurementGroup",
"display" : "ImagingMeasurementGroup",
"relationship" : "equivalent",
"comment" : "Measurement Group children of a derived imaging measurement content item are mapped to new ImagingMeasurementGroup observations."
},
{
"code" : "derivedFrom",
"display" : "DerivedImagingMeasurement.derivedFrom",
"relationship" : "equivalent"
}
]
}
]
}
]
}