This page is part of the CardX Hypertension Management IG (v1.0.0: STU1) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/uv/cardx-htn-mng/StructureDefinition/average-smbp | Version: 1.0.0 | |||
Draft as of 2024-12-12 | Computable Name: AverageSMBP |
The calculated average of two or more blood pressure readings that are taken in a non-clinical environment by the subject, or a related person. The readings are obtained within a specified time period or according to a specified algorithm or protocol (e.g., (e.g. AHA/AMA Target:BP Measurement Guidelines or Systolic Blood Pressure Intervention Trail (SPRINT)). The average blood pressure has systolic and diastolic components. (Note: This definition aligns with the description for Average Blood Pressure in USCDI V4.)
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Observation
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | Observation | Measurements and simple assertions vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. |
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |
NumberOfMeasurements | S | 1..1 | integer | Number of Measurements URL: http://hl7.org/fhir/uv/cardx-htn-mng/StructureDefinition/NumberOfMeasurementsExt |
status | S | 1..1 | code | registered | preliminary | final | amended + Binding: SMBP Observation Status value set (required) |
category | S | 1..* | CodeableConcept | Classification of type of observation Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |
code | S | 1..1 | CodeableConcept | Average blood pressure Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |
subject | S | 1..1 | Reference(Patient) | Who and/or what the observation is about |
effective[x] | S | 1..1 | Period | The time range in which measurements were taken to calculate the average. |
start | 1..1 | dateTime | Starting time with inclusive boundary | |
end | 1..1 | dateTime | End time with inclusive boundary, if not ongoing | |
issued | S | 1..1 | instant | Date/Time this version was made available |
performer | S | 1..1 | Reference(Patient) | Who is responsible for the observation |
value[x] | 0..0 | |||
dataAbsentReason | S | 0..1 | CodeableConcept | Why the result is missing |
derivedFrom | S | 0..* | Reference(Self-measured Blood Pressure) | Related measurements the observation is made from |
Slices for component | SC | 2..* | BackboneElement | Blood pressure components Slice: Unordered, Open by value:code vs-3: If there is not a value a data absent reason must be present |
component:All Slices | Content/Rules for all slices | |||
code | S | 1..1 | CodeableConcept | Type of component observation (code / type) |
value[x] | S | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Actual component result |
dataAbsentReason | S | 0..1 | CodeableConcept | Why the component result is missing |
component:SystolicBP | S | 1..1 | BackboneElement | Systolic blood pressure mean |
code | 1..1 | CodeableConcept | Systolic blood pressure mean Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |
value[x] | 0..1 | Quantity | Actual component result | |
value | S | 1..1 | decimal | Numerical value (with implicit precision) |
unit | S | 1..1 | string | Unit representation |
system | S | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
component:DiastolicBP | S | 1..1 | BackboneElement | Diastolic blood pressure mean |
code | 1..1 | CodeableConcept | Diastolic blood pressure mean Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |
value[x] | 0..1 | Quantity | Actual component result | |
value | S | 1..1 | decimal | Numerical value (with implicit precision) |
unit | S | 1..1 | string | Unit representation |
system | S | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.status | required | SMBPStatusVShttp://hl7.org/fhir/uv/cardx-htn-mng/ValueSet/smbp-obs-status from this IG |
Id | Grade | Path(s) | Details | Requirements |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component | If there is not a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | Observation | Measurements and simple assertions dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
NumberOfMeasurements | S | 1..1 | integer | Number of Measurements URL: http://hl7.org/fhir/uv/cardx-htn-mng/StructureDefinition/NumberOfMeasurementsExt ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: SMBP Observation Status value set (required) ele-1: All FHIR elements must have a @value or children |
category | S | 1..* | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. ele-1: All FHIR elements must have a @value or children Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |
code | SΣ | 1..1 | CodeableConcept | Average blood pressure Binding: LOINCCodes (example): Codes identifying names of simple observations. ele-1: All FHIR elements must have a @value or children Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about ele-1: All FHIR elements must have a @value or children |
effective[x] | SΣ | 1..1 | Period | The time range in which measurements were taken to calculate the average. ele-1: All FHIR elements must have a @value or children |
start | ΣC | 1..1 | dateTime | Starting time with inclusive boundary ele-1: All FHIR elements must have a @value or children |
end | ΣC | 1..1 | dateTime | End time with inclusive boundary, if not ongoing ele-1: All FHIR elements must have a @value or children |
issued | SΣ | 1..1 | instant | Date/Time this version was made available ele-1: All FHIR elements must have a @value or children |
performer | SΣ | 1..1 | Reference(Patient) | Who is responsible for the observation ele-1: All FHIR elements must have a @value or children |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. ele-1: All FHIR elements must have a @value or children |
derivedFrom | SΣ | 0..* | Reference(Self-measured Blood Pressure) | Related measurements the observation is made from ele-1: All FHIR elements must have a @value or children |
Slices for component | SΣC | 2..* | BackboneElement | Blood pressure components Slice: Unordered, Open by value:code ele-1: All FHIR elements must have a @value or children vs-3: If there is not a value a data absent reason must be present |
component:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. ele-1: All FHIR elements must have a @value or children |
value[x] | SΣ | 0..1 | Actual component result ele-1: All FHIR elements must have a @value or children | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. ele-1: All FHIR elements must have a @value or children |
component:SystolicBP | SΣ | 1..1 | BackboneElement | Systolic blood pressure mean ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | Σ | 1..1 | CodeableConcept | Systolic blood pressure mean Binding: LOINCCodes (example): Codes identifying names of simple observations. ele-1: All FHIR elements must have a @value or children Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |
value[x] | Σ | 0..1 | Quantity | Actual component result ele-1: All FHIR elements must have a @value or children |
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) ele-1: All FHIR elements must have a @value or children |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. ele-1: All FHIR elements must have a @value or children |
unit | SΣ | 1..1 | string | Unit representation ele-1: All FHIR elements must have a @value or children |
system | SΣC | 1..1 | uri | System that defines coded unit form ele-1: All FHIR elements must have a @value or children Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded form of the unit ele-1: All FHIR elements must have a @value or children Fixed Value: mm[Hg] |
component:DiastolicBP | SΣ | 1..1 | BackboneElement | Diastolic blood pressure mean ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | Σ | 1..1 | CodeableConcept | Diastolic blood pressure mean Binding: LOINCCodes (example): Codes identifying names of simple observations. ele-1: All FHIR elements must have a @value or children Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |
value[x] | Σ | 0..1 | Quantity | Actual component result ele-1: All FHIR elements must have a @value or children |
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) ele-1: All FHIR elements must have a @value or children |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. ele-1: All FHIR elements must have a @value or children |
unit | SΣ | 1..1 | string | Unit representation ele-1: All FHIR elements must have a @value or children |
system | SΣC | 1..1 | uri | System that defines coded unit form ele-1: All FHIR elements must have a @value or children Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded form of the unit ele-1: All FHIR elements must have a @value or children Fixed Value: mm[Hg] |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Observation.status | required | SMBPStatusVShttp://hl7.org/fhir/uv/cardx-htn-mng/ValueSet/smbp-obs-status from this IG | |
Observation.category | preferred | Pattern: vital-signshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | example | Pattern: LOINC Code 96607-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component:SystolicBP.code | example | Pattern: LOINC Code 96608-5http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component:SystolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.component:DiastolicBP.code | example | Pattern: LOINC Code 96609-3http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component:DiastolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component | If there is not a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | Observation | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
NumberOfMeasurements | S | 1..1 | integer | Number of Measurements URL: http://hl7.org/fhir/uv/cardx-htn-mng/StructureDefinition/NumberOfMeasurementsExt | ||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: SMBP Observation Status value set (required) | ||||
category | S | 1..* | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | SΣ | 1..1 | CodeableConcept | Average blood pressure Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣ | 1..1 | Period | The time range in which measurements were taken to calculate the average. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
start | ΣC | 1..1 | dateTime | Starting time with inclusive boundary | ||||
end | ΣC | 1..1 | dateTime | End time with inclusive boundary, if not ongoing | ||||
issued | SΣ | 1..1 | instant | Date/Time this version was made available | ||||
performer | SΣ | 1..1 | Reference(Patient) | Who is responsible for the observation | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Related resource that belongs to the Observation group | ||||
derivedFrom | SΣ | 0..* | Reference(Self-measured Blood Pressure) | Related measurements the observation is made from | ||||
Slices for component | SΣC | 2..* | BackboneElement | Blood pressure components Slice: Unordered, Open by value:code vs-3: If there is not a value a data absent reason must be present | ||||
component:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | SΣ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:SystolicBP | SΣ | 1..1 | BackboneElement | Systolic blood pressure mean | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Systolic blood pressure mean Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | Σ | 0..1 | Quantity | Actual component result | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | Unit representation | ||||
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:DiastolicBP | SΣ | 1..1 | BackboneElement | Diastolic blood pressure mean | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Diastolic blood pressure mean Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | Σ | 0..1 | Quantity | Actual component result | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | Unit representation | ||||
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | URI | |||
Observation.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages from the FHIR Standard
| ||||
Observation.status | required | SMBPStatusVShttp://hl7.org/fhir/uv/cardx-htn-mng/ValueSet/smbp-obs-status from this IG | ||||
Observation.category | preferred | Pattern: vital-signshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | example | Pattern: LOINC Code 96607-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:SystolicBP.code | example | Pattern: LOINC Code 96608-5http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component:SystolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:SystolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:SystolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:DiastolicBP.code | example | Pattern: LOINC Code 96609-3http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component:DiastolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:DiastolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:DiastolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component | If there is not a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
This structure is derived from Observation
Summary
Mandatory: 11 elements(8 nested mandatory elements)
Must-Support: 24 elements
Fixed: 4 elements
Prohibited: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Differential View
This structure is derived from Observation
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | Observation | Measurements and simple assertions vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. |
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |
NumberOfMeasurements | S | 1..1 | integer | Number of Measurements URL: http://hl7.org/fhir/uv/cardx-htn-mng/StructureDefinition/NumberOfMeasurementsExt |
status | S | 1..1 | code | registered | preliminary | final | amended + Binding: SMBP Observation Status value set (required) |
category | S | 1..* | CodeableConcept | Classification of type of observation Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |
code | S | 1..1 | CodeableConcept | Average blood pressure Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |
subject | S | 1..1 | Reference(Patient) | Who and/or what the observation is about |
effective[x] | S | 1..1 | Period | The time range in which measurements were taken to calculate the average. |
start | 1..1 | dateTime | Starting time with inclusive boundary | |
end | 1..1 | dateTime | End time with inclusive boundary, if not ongoing | |
issued | S | 1..1 | instant | Date/Time this version was made available |
performer | S | 1..1 | Reference(Patient) | Who is responsible for the observation |
value[x] | 0..0 | |||
dataAbsentReason | S | 0..1 | CodeableConcept | Why the result is missing |
derivedFrom | S | 0..* | Reference(Self-measured Blood Pressure) | Related measurements the observation is made from |
Slices for component | SC | 2..* | BackboneElement | Blood pressure components Slice: Unordered, Open by value:code vs-3: If there is not a value a data absent reason must be present |
component:All Slices | Content/Rules for all slices | |||
code | S | 1..1 | CodeableConcept | Type of component observation (code / type) |
value[x] | S | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Actual component result |
dataAbsentReason | S | 0..1 | CodeableConcept | Why the component result is missing |
component:SystolicBP | S | 1..1 | BackboneElement | Systolic blood pressure mean |
code | 1..1 | CodeableConcept | Systolic blood pressure mean Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |
value[x] | 0..1 | Quantity | Actual component result | |
value | S | 1..1 | decimal | Numerical value (with implicit precision) |
unit | S | 1..1 | string | Unit representation |
system | S | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
component:DiastolicBP | S | 1..1 | BackboneElement | Diastolic blood pressure mean |
code | 1..1 | CodeableConcept | Diastolic blood pressure mean Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |
value[x] | 0..1 | Quantity | Actual component result | |
value | S | 1..1 | decimal | Numerical value (with implicit precision) |
unit | S | 1..1 | string | Unit representation |
system | S | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.status | required | SMBPStatusVShttp://hl7.org/fhir/uv/cardx-htn-mng/ValueSet/smbp-obs-status from this IG |
Id | Grade | Path(s) | Details | Requirements |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component | If there is not a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | Observation | Measurements and simple assertions dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
NumberOfMeasurements | S | 1..1 | integer | Number of Measurements URL: http://hl7.org/fhir/uv/cardx-htn-mng/StructureDefinition/NumberOfMeasurementsExt ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: SMBP Observation Status value set (required) ele-1: All FHIR elements must have a @value or children |
category | S | 1..* | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. ele-1: All FHIR elements must have a @value or children Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |
code | SΣ | 1..1 | CodeableConcept | Average blood pressure Binding: LOINCCodes (example): Codes identifying names of simple observations. ele-1: All FHIR elements must have a @value or children Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about ele-1: All FHIR elements must have a @value or children |
effective[x] | SΣ | 1..1 | Period | The time range in which measurements were taken to calculate the average. ele-1: All FHIR elements must have a @value or children |
start | ΣC | 1..1 | dateTime | Starting time with inclusive boundary ele-1: All FHIR elements must have a @value or children |
end | ΣC | 1..1 | dateTime | End time with inclusive boundary, if not ongoing ele-1: All FHIR elements must have a @value or children |
issued | SΣ | 1..1 | instant | Date/Time this version was made available ele-1: All FHIR elements must have a @value or children |
performer | SΣ | 1..1 | Reference(Patient) | Who is responsible for the observation ele-1: All FHIR elements must have a @value or children |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. ele-1: All FHIR elements must have a @value or children |
derivedFrom | SΣ | 0..* | Reference(Self-measured Blood Pressure) | Related measurements the observation is made from ele-1: All FHIR elements must have a @value or children |
Slices for component | SΣC | 2..* | BackboneElement | Blood pressure components Slice: Unordered, Open by value:code ele-1: All FHIR elements must have a @value or children vs-3: If there is not a value a data absent reason must be present |
component:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. ele-1: All FHIR elements must have a @value or children |
value[x] | SΣ | 0..1 | Actual component result ele-1: All FHIR elements must have a @value or children | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. ele-1: All FHIR elements must have a @value or children |
component:SystolicBP | SΣ | 1..1 | BackboneElement | Systolic blood pressure mean ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | Σ | 1..1 | CodeableConcept | Systolic blood pressure mean Binding: LOINCCodes (example): Codes identifying names of simple observations. ele-1: All FHIR elements must have a @value or children Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |
value[x] | Σ | 0..1 | Quantity | Actual component result ele-1: All FHIR elements must have a @value or children |
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) ele-1: All FHIR elements must have a @value or children |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. ele-1: All FHIR elements must have a @value or children |
unit | SΣ | 1..1 | string | Unit representation ele-1: All FHIR elements must have a @value or children |
system | SΣC | 1..1 | uri | System that defines coded unit form ele-1: All FHIR elements must have a @value or children Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded form of the unit ele-1: All FHIR elements must have a @value or children Fixed Value: mm[Hg] |
component:DiastolicBP | SΣ | 1..1 | BackboneElement | Diastolic blood pressure mean ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | Σ | 1..1 | CodeableConcept | Diastolic blood pressure mean Binding: LOINCCodes (example): Codes identifying names of simple observations. ele-1: All FHIR elements must have a @value or children Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |
value[x] | Σ | 0..1 | Quantity | Actual component result ele-1: All FHIR elements must have a @value or children |
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) ele-1: All FHIR elements must have a @value or children |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. ele-1: All FHIR elements must have a @value or children |
unit | SΣ | 1..1 | string | Unit representation ele-1: All FHIR elements must have a @value or children |
system | SΣC | 1..1 | uri | System that defines coded unit form ele-1: All FHIR elements must have a @value or children Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded form of the unit ele-1: All FHIR elements must have a @value or children Fixed Value: mm[Hg] |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Observation.status | required | SMBPStatusVShttp://hl7.org/fhir/uv/cardx-htn-mng/ValueSet/smbp-obs-status from this IG | |
Observation.category | preferred | Pattern: vital-signshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | example | Pattern: LOINC Code 96607-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component:SystolicBP.code | example | Pattern: LOINC Code 96608-5http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component:SystolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.component:DiastolicBP.code | example | Pattern: LOINC Code 96609-3http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component:DiastolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component | If there is not a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | Observation | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
NumberOfMeasurements | S | 1..1 | integer | Number of Measurements URL: http://hl7.org/fhir/uv/cardx-htn-mng/StructureDefinition/NumberOfMeasurementsExt | ||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: SMBP Observation Status value set (required) | ||||
category | S | 1..* | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | SΣ | 1..1 | CodeableConcept | Average blood pressure Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96607-7 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣ | 1..1 | Period | The time range in which measurements were taken to calculate the average. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
start | ΣC | 1..1 | dateTime | Starting time with inclusive boundary | ||||
end | ΣC | 1..1 | dateTime | End time with inclusive boundary, if not ongoing | ||||
issued | SΣ | 1..1 | instant | Date/Time this version was made available | ||||
performer | SΣ | 1..1 | Reference(Patient) | Who is responsible for the observation | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Related resource that belongs to the Observation group | ||||
derivedFrom | SΣ | 0..* | Reference(Self-measured Blood Pressure) | Related measurements the observation is made from | ||||
Slices for component | SΣC | 2..* | BackboneElement | Blood pressure components Slice: Unordered, Open by value:code vs-3: If there is not a value a data absent reason must be present | ||||
component:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | SΣ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:SystolicBP | SΣ | 1..1 | BackboneElement | Systolic blood pressure mean | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Systolic blood pressure mean Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96608-5 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | Σ | 0..1 | Quantity | Actual component result | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | Unit representation | ||||
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:DiastolicBP | SΣ | 1..1 | BackboneElement | Diastolic blood pressure mean | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Diastolic blood pressure mean Binding: LOINCCodes (example): Codes identifying names of simple observations. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 96609-3 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | Σ | 0..1 | Quantity | Actual component result | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | Unit representation | ||||
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | URI | |||
Observation.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages from the FHIR Standard
| ||||
Observation.status | required | SMBPStatusVShttp://hl7.org/fhir/uv/cardx-htn-mng/ValueSet/smbp-obs-status from this IG | ||||
Observation.category | preferred | Pattern: vital-signshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | example | Pattern: LOINC Code 96607-7http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:SystolicBP.code | example | Pattern: LOINC Code 96608-5http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component:SystolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:SystolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:SystolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.component:DiastolicBP.code | example | Pattern: LOINC Code 96609-3http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component:DiastolicBP.value[x].comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.component:DiastolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component:DiastolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component | If there is not a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
This structure is derived from Observation
Summary
Mandatory: 11 elements(8 nested mandatory elements)
Must-Support: 24 elements
Fixed: 4 elements
Prohibited: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron