This page is part of the PACIO Personal Functioning and Engagement Implementation Guide (v1.0.0: STU 1) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/pfe-observation-single | Version: 1.0.0 | |||
Draft as of 2024-01-05 | Computable Name: PFESingleObservation |
An exchange of post-acute care observation for a patient. This profile is used for exchanging an observation for a single question generally included in a structured resource (e.g., assessment tool, instrument, or screen).
Example Usage Scenarios:
The following are example usage scenarios for this Profile:
The following data elements must always be present or must be supported if the data is present in the sending system (Must Support definition). They are presented below with a simple human-readable explanation. Profile specific guidance and examples are provided as well. The Formal Profile Definition below provides the formal summary, definitions, and terminology requirements.
Each Personal Functioning and Engagement Observation must have:
Each Personal Functioning and Engagement Observation must support:
* ** *** see guidance below
Profile specific implementation guidance:
Rather than offer a separate Observation profile for each PFE category (also called domain – e.g., Mental Functions, Mobility, etc.), this profile can support any PFE category. The PFE Domain can be specified in a CodeableConcept in the Observation.category slice. Based on the code selected for the optional Observation.category slice, the Table below provides the PACIO-vetted, example value sets that contain the Assessment Observation codes to be placed in Observation.code for the selected domain. Where a preferred value set contains a code to describe a needed concept, servers SHOULD use that code. For more information regarding the ICF categorization process, and how to categorize new codes, see: domains
Observation.category |
Domain | Element binding | Assessment Observation Codes ValueSet |
---|---|---|---|
mental-functions | Mental functions | Observation.code | PFE- Mental functions ValueSet |
sensory_functions_and_pain | Sensory functions and pain | Observation.code | PFE - Sensory functions and pain ValueSet |
voice_and_speech_functions | Voice and speech functions | Observation.code | PFE- Voice and speech functions ValueSet |
functions_of_the_digestive_metabolic_and_endocrine_systems | Functions of the digestive, metabolic and endocrine systems | Observation.code | PFE - Functions of the digestive, metabolic and endocrine systems ValueSet |
genitourinary_and_reproductive_functions | Genitourinary and reproductive functions | Observation.code | PFE- Genitourinary and reproductive functions ValueSet |
neuromusculoskeletal_and_movement-related_functions | Neuromusculoskeletal and movement-related functions | Observation.code | PFE- Neuromusculoskeletal and movement-related functions ValueSet |
functions_of_the_skin_and_related_structures | Functions of the skin and related structures | Observation.code | PFE- Functions of the skin and related structures ValueSet |
Observation.category |
Domain | Element binding | Assessment Observation Codes ValueSet |
---|---|---|---|
learning_and_applying_knowledge | Learning and applying knowledge | Observation.code | PFE - Learning and applying knowledge ValueSet |
communication | Communication | Observation.code | PFE - Communication ValueSet |
mobility | Mobility | Observation.code | PFE - Mobility ValueSet |
self-care | Self-care | Observation.code | PFE - Self-care ValueSet |
domestic_life | Domestic life | Observation.code | PFE - Domestic life ValueSet |
Observation.category |
Domain | Element binding | Assessment Observation Codes ValueSet |
---|---|---|---|
body-structures | Body structures | Observation.code | PFE - Body structures ValueSet |
structures_involved_in_voice_and_speech | Structures involved in voice and speech | Observation.code | PFE - Structures involved in voice and speech ValueSet |
| Observation.category
| Domain | Element binding | Assessment Observation Codes ValueSet |
| —— | ——————– | ————————- | ———— |
| products_and_technology | Products and technology | Observation.code | PFE - Products and Technology ValueSet |
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from USCoreObservationSurveyProfile
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | USCoreObservationSurveyProfile | |||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
event-location | S | 0..1 | Reference(US Core Location Profile) | An extension to indicate where the observation event occurred. URL: http://hl7.org/fhir/StructureDefinition/event-location profiled by http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/event-location |
device-use | S | 0..* | Reference(Personal Functioning and Engagement Use of Device) | An extension to indicate a record of assistive device usage by a patient during an assessment. URL: http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/device-patient-used |
status | 1..1 | code | Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used. | |
category | 2..* | CodeableConcept | Classification of type of observation | |
category:functioning | S | 1..1 | CodeableConcept | Classification of type of observation Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/pacio-pfe/CodeSystem/pfe-functioning-cs | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: functioning | |
display | 1..1 | string | Representation defined by the system Fixed Value: Functioning | |
category:PFEDomain | S | 0..* | CodeableConcept | Classification of type of observation Binding: Personal Functioning and Engagement Category Value Set (required) |
code | 1..1 | CodeableConcept | For PFE Assessments, should include a LOINC code and text for the question or concept name. | |
effective[x] | 1..1 | dateTime | Clinically relevant time/time-period for observation | |
performer | 1..* | Reference(US Core Practitioner Profile | US Core PractitionerRole Profile | US Core Organization Profile) | The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization. | |
value[x] | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension. | |
hasMember | 0..0 | |||
derivedFrom | 0..* | Reference(US Core QuestionnaireResponse Profile | US Core Observation Survey Profile) | Should point back to the QuestionnaireResponse that this resource is derived from. | |
Documentation for this format |
Path | Conformance | ValueSet |
Observation.category:PFEDomain | required | PFECategoryVS (a valid code from Personal Functioning and Engagement Category) |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | USCoreObservationSurveyProfile | Survey Observation |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
event-location | S | 0..1 | Reference(US Core Location Profile) | An extension to indicate where the observation event occurred. URL: http://hl7.org/fhir/StructureDefinition/event-location profiled by http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/event-location |
device-use | S | 0..* | Reference(Personal Functioning and Engagement Use of Device) | An extension to indicate a record of assistive device usage by a patient during an assessment. URL: http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/device-patient-used |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used. Binding: ObservationStatus (required): Codes providing the status of an observation. |
Slices for category | S | 2..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:survey | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: survey | |
category:functioning | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/pacio-pfe/CodeSystem/pfe-functioning-cs | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: functioning | |
display | 1..1 | string | Representation defined by the system Fixed Value: Functioning | |
category:PFEDomain | S | 0..* | CodeableConcept | Classification of type of observation Binding: Personal Functioning and Engagement Category Value Set (required) |
code | SΣ | 1..1 | CodeableConcept | For PFE Assessments, should include a LOINC code and text for the question or concept name. Binding: US Core Survey Codes (preferred) |
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about |
effective[x] | SΣC | 1..1 | dateTime | Clinically relevant time/time-period for observation |
performer | SΣ | 1..* | Reference(US Core Practitioner Profile) | The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization. |
value[x] | SΣC | 0..1 | Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension. | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
derivedFrom | SΣ | 0..* | Reference(US Core QuestionnaireResponse Profile | US Core Observation Survey Profile) | Should point back to the QuestionnaireResponse that this resource is derived from. |
Documentation for this format |
Path | Conformance | ValueSet / Code |
Observation.status | required | ObservationStatus |
Observation.category | preferred | ObservationCategoryCodes |
Observation.category:survey | preferred | Pattern: survey |
Observation.category:functioning | preferred | Pattern: functioning("Functioning") |
Observation.category:PFEDomain | required | PFECategoryVS (a valid code from Personal Functioning and Engagement Category) |
Observation.code | preferred | USCoreSurveyCodes |
Observation.dataAbsentReason | extensible | DataAbsentReason |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | USCoreObservationSurveyProfile | Survey Observation | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
event-location | S | 0..1 | Reference(US Core Location Profile) | An extension to indicate where the observation event occurred. URL: http://hl7.org/fhir/StructureDefinition/event-location profiled by http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/event-location | ||||
device-use | S | 0..* | Reference(Personal Functioning and Engagement Use of Device) | An extension to indicate a record of assistive device usage by a patient during an assessment. URL: http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/device-patient-used | ||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used. Binding: ObservationStatus (required): Codes providing the status of an observation. | ||||
Slices for category | S | 2..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:survey | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: survey | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
category:functioning | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/pacio-pfe/CodeSystem/pfe-functioning-cs | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: functioning | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Functioning | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
category:PFEDomain | S | 0..* | CodeableConcept | Classification of type of observation Binding: Personal Functioning and Engagement Category Value Set (required) | ||||
code | SΣ | 1..1 | CodeableConcept | For PFE Assessments, should include a LOINC code and text for the question or concept name. Binding: US Core Survey Codes (preferred) | ||||
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 1..1 | dateTime S | Clinically relevant time/time-period for observation | ||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | SΣ | 1..* | Reference(US Core Practitioner Profile S | US Core PractitionerRole Profile | US Core Organization Profile) | The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization. | ||||
value[x] | SΣC | 0..1 | Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension. | |||||
valueQuantity | Quantity S | |||||||
valueCodeableConcept | CodeableConcept S | |||||||
valueString | string S | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
derivedFrom | SΣ | 0..* | Reference(US Core QuestionnaireResponse Profile S | US Core Observation Survey Profile S) | Should point back to the QuestionnaireResponse that this resource is derived from. | ||||
component | Σ | 0..* | BackboneElement | Component results | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | Σ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | ||||
Observation.language | preferred | CommonLanguages
| ||||
Observation.status | required | ObservationStatus | ||||
Observation.category | preferred | ObservationCategoryCodes | ||||
Observation.category:survey | preferred | Pattern: survey | ||||
Observation.category:functioning | preferred | Pattern: functioning("Functioning") | ||||
Observation.category:PFEDomain | required | PFECategoryVS (a valid code from Personal Functioning and Engagement Category) | ||||
Observation.code | preferred | USCoreSurveyCodes | ||||
Observation.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.bodySite | example | SNOMEDCTBodyStructures | ||||
Observation.method | example | ObservationMethods | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodes | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodes | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC) | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodes |
This structure is derived from USCoreObservationSurveyProfile
Summary
Mandatory: 3 elements
Must-Support: 4 elements
Prohibited: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Differential View
This structure is derived from USCoreObservationSurveyProfile
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | USCoreObservationSurveyProfile | |||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
event-location | S | 0..1 | Reference(US Core Location Profile) | An extension to indicate where the observation event occurred. URL: http://hl7.org/fhir/StructureDefinition/event-location profiled by http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/event-location |
device-use | S | 0..* | Reference(Personal Functioning and Engagement Use of Device) | An extension to indicate a record of assistive device usage by a patient during an assessment. URL: http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/device-patient-used |
status | 1..1 | code | Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used. | |
category | 2..* | CodeableConcept | Classification of type of observation | |
category:functioning | S | 1..1 | CodeableConcept | Classification of type of observation Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/pacio-pfe/CodeSystem/pfe-functioning-cs | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: functioning | |
display | 1..1 | string | Representation defined by the system Fixed Value: Functioning | |
category:PFEDomain | S | 0..* | CodeableConcept | Classification of type of observation Binding: Personal Functioning and Engagement Category Value Set (required) |
code | 1..1 | CodeableConcept | For PFE Assessments, should include a LOINC code and text for the question or concept name. | |
effective[x] | 1..1 | dateTime | Clinically relevant time/time-period for observation | |
performer | 1..* | Reference(US Core Practitioner Profile | US Core PractitionerRole Profile | US Core Organization Profile) | The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization. | |
value[x] | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension. | |
hasMember | 0..0 | |||
derivedFrom | 0..* | Reference(US Core QuestionnaireResponse Profile | US Core Observation Survey Profile) | Should point back to the QuestionnaireResponse that this resource is derived from. | |
Documentation for this format |
Path | Conformance | ValueSet |
Observation.category:PFEDomain | required | PFECategoryVS (a valid code from Personal Functioning and Engagement Category) |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | USCoreObservationSurveyProfile | Survey Observation |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
event-location | S | 0..1 | Reference(US Core Location Profile) | An extension to indicate where the observation event occurred. URL: http://hl7.org/fhir/StructureDefinition/event-location profiled by http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/event-location |
device-use | S | 0..* | Reference(Personal Functioning and Engagement Use of Device) | An extension to indicate a record of assistive device usage by a patient during an assessment. URL: http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/device-patient-used |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used. Binding: ObservationStatus (required): Codes providing the status of an observation. |
Slices for category | S | 2..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:survey | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: survey | |
category:functioning | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/pacio-pfe/CodeSystem/pfe-functioning-cs | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: functioning | |
display | 1..1 | string | Representation defined by the system Fixed Value: Functioning | |
category:PFEDomain | S | 0..* | CodeableConcept | Classification of type of observation Binding: Personal Functioning and Engagement Category Value Set (required) |
code | SΣ | 1..1 | CodeableConcept | For PFE Assessments, should include a LOINC code and text for the question or concept name. Binding: US Core Survey Codes (preferred) |
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about |
effective[x] | SΣC | 1..1 | dateTime | Clinically relevant time/time-period for observation |
performer | SΣ | 1..* | Reference(US Core Practitioner Profile) | The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization. |
value[x] | SΣC | 0..1 | Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension. | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
derivedFrom | SΣ | 0..* | Reference(US Core QuestionnaireResponse Profile | US Core Observation Survey Profile) | Should point back to the QuestionnaireResponse that this resource is derived from. |
Documentation for this format |
Path | Conformance | ValueSet / Code |
Observation.status | required | ObservationStatus |
Observation.category | preferred | ObservationCategoryCodes |
Observation.category:survey | preferred | Pattern: survey |
Observation.category:functioning | preferred | Pattern: functioning("Functioning") |
Observation.category:PFEDomain | required | PFECategoryVS (a valid code from Personal Functioning and Engagement Category) |
Observation.code | preferred | USCoreSurveyCodes |
Observation.dataAbsentReason | extensible | DataAbsentReason |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | USCoreObservationSurveyProfile | Survey Observation | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
event-location | S | 0..1 | Reference(US Core Location Profile) | An extension to indicate where the observation event occurred. URL: http://hl7.org/fhir/StructureDefinition/event-location profiled by http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/event-location | ||||
device-use | S | 0..* | Reference(Personal Functioning and Engagement Use of Device) | An extension to indicate a record of assistive device usage by a patient during an assessment. URL: http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/device-patient-used | ||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used. Binding: ObservationStatus (required): Codes providing the status of an observation. | ||||
Slices for category | S | 2..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:survey | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: survey | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
category:functioning | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/pacio-pfe/CodeSystem/pfe-functioning-cs | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: functioning | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Functioning | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
category:PFEDomain | S | 0..* | CodeableConcept | Classification of type of observation Binding: Personal Functioning and Engagement Category Value Set (required) | ||||
code | SΣ | 1..1 | CodeableConcept | For PFE Assessments, should include a LOINC code and text for the question or concept name. Binding: US Core Survey Codes (preferred) | ||||
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 1..1 | dateTime S | Clinically relevant time/time-period for observation | ||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | SΣ | 1..* | Reference(US Core Practitioner Profile S | US Core PractitionerRole Profile | US Core Organization Profile) | The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization. | ||||
value[x] | SΣC | 0..1 | Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension. | |||||
valueQuantity | Quantity S | |||||||
valueCodeableConcept | CodeableConcept S | |||||||
valueString | string S | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
derivedFrom | SΣ | 0..* | Reference(US Core QuestionnaireResponse Profile S | US Core Observation Survey Profile S) | Should point back to the QuestionnaireResponse that this resource is derived from. | ||||
component | Σ | 0..* | BackboneElement | Component results | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | Σ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | ||||
Observation.language | preferred | CommonLanguages
| ||||
Observation.status | required | ObservationStatus | ||||
Observation.category | preferred | ObservationCategoryCodes | ||||
Observation.category:survey | preferred | Pattern: survey | ||||
Observation.category:functioning | preferred | Pattern: functioning("Functioning") | ||||
Observation.category:PFEDomain | required | PFECategoryVS (a valid code from Personal Functioning and Engagement Category) | ||||
Observation.code | preferred | USCoreSurveyCodes | ||||
Observation.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.bodySite | example | SNOMEDCTBodyStructures | ||||
Observation.method | example | ObservationMethods | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodes | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodes | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC) | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodes |
This structure is derived from USCoreObservationSurveyProfile
Summary
Mandatory: 3 elements
Must-Support: 4 elements
Prohibited: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Other representations of profile: CSV, Excel, Schematron
The syntax used to describe the interactions below is described here.
The following search parameters and search parameter combinations SHALL be supported:
SHALL support searching using the combination of the patient
and category
search parameters:
GET [base]/Observation?patient={Type/}[id]&category={system|}[code]
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and a category code = survey
or mental_functions
respectively (how to search by reference and how to search by token)
patient
and code
search parameters:
code
(e.g.code={system|}[code],{system|}[code],...
)GET [base]/Observation?patient={Type/}[id]&code={system|}[code]{,{system|}[code],...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and observation code(s). SHOULD support search by multiple report codes. The Observation code
parameter searches `Observation.code only. (how to search by reference and how to search by token)
patient
and category
and date
search parameters:
date
comparators: gt,lt,ge,le
date
(e.g.date=[date]&date=[date]]&...
)GET [base]/Observation?patient={Type/}[id]&category={system|}[code]&date={gt|lt|ge|le}[date]{&date={gt|lt|ge|le}[date]&...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and date and a category code = survey
or mental_functions
respectively (how to search by reference and how to search by token and how to search by date)
The following search parameter combinations SHOULD be supported:
patient
and category
and status
search parameters:
status
(e.g.status={system|}[code],{system|}[code],...
)GET [base]/Observation?patient={Type/}[id]&category={system|}[code]&status={system|}[code]{,{system|}[code],...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and category = survey
or mental_functions
respectively and status final
(how to search by reference and how to search by token)
patient
and code
and date
search parameters:
code
(e.g.code={system|}[code],{system|}[code],...
)date
comparators: gt,lt,ge,le
date
(e.g.date=[date]&date=[date]]&...
)GET [base]/Observation?patient={Type/}[id]&code={system|}[code]{,{system|}[code],...}&date={gt|lt|ge|le}[date]{&date={gt|lt|ge|le}[date]&...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and date and report code(s). SHOULD support search by multiple report codes. (how to search by reference and how to search by token and how to search by date)