This page is part of the HL7 FHIR Implementation Guide: minimal Common Oncology Data Elements (mCODE) Release 1 - US Realm | STU1 (v3.0.0: STU 3) based on FHIR R4. This is the current published version. For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-ecog-performance-status | Version: 3.0.0 | |||
Draft as of 2023-10-26 | Maturity Level: 4 | Computable Name: ECOGPerformanceStatus |
The Eastern Cooperative Oncology Group (ECOG) Performance Status represents the patient’s functional status and is used to determine their ability to tolerate therapies in serious illness, specifically for chemotherapy. (Definition from: LOINC)
Observation resources associated with an in-scope patient with Observation.code
LOINC 89247-1
SHALL conform to this profile. Beyond this requirement, a producer of resources SHOULD ensure that any resource instance associated with an in-scope patient that would reasonably be expected to conform to this profile SHOULD be published in this form.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from USCoreObservationClinicalTestResultProfile
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | USCoreObservationClinicalTestResultProfile | Measurements and simple assertions | |
basedOn | 0..* | Reference(ServiceRequest | CarePlan) | Fulfills plan, proposal or order | |
partOf | 0..* | Reference(Procedure) | Part of referenced event | |
code | 1..1 | CodeableConcept | Clinical Test Name Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 89247-1 | |
subject | 1..1 | Reference(Cancer Patient Profile) | Who and/or what the observation is about | |
effective[x] | 0..1 | Clinically relevant time/time-period for observation | ||
effectiveDateTime | dateTime | |||
effectivePeriod | Period | |||
value[x] | 0..1 | integer | Result Value | |
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: LOINC Answer List LL529-9 (required) |
bodySite | 0..1 | CodeableConcept | Not used in this profile | |
specimen | 0..1 | Reference(Specimen) | Not used in this profile | |
device | 0..1 | Reference(Device | DeviceMetric) | Not used in this profile | |
hasMember | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Not used in this profile | |
component | 0..* | BackboneElement | Not used in this profile | |
Documentation for this format |
Path | Conformance | ValueSet |
Observation.interpretation | required | LOINC LL529-9 |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | USCoreObservationClinicalTestResultProfile | Measurements and simple assertions |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
basedOn | Σ | 0..* | Reference(ServiceRequest | CarePlan) | Fulfills plan, proposal or order |
partOf | Σ | 0..* | Reference(Procedure) | Part of referenced event |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. |
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:clinical-test | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/core/CodeSystem/us-core-observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: clinical-test | |
code | SΣ | 1..1 | CodeableConcept | Clinical Test Name Binding: US Core Clinical Test Codes (extensible) Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 89247-1 | |
subject | SΣ | 1..1 | Reference(Cancer Patient Profile) | Who and/or what the observation is about |
effective[x] | SΣC | 0..1 | Clinically relevant time/time-period for observation | |
effectiveDateTime | dateTime | |||
value[x] | SΣC | 0..1 | integer | Result Value |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: LOINC Answer List LL529-9 (required) |
bodySite | 0..1 | CodeableConcept | Not used in this profile Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |
specimen | 0..1 | Reference(Specimen) | Not used in this profile | |
device | 0..1 | Reference(Device | DeviceMetric) | Not used in this profile | |
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Not used in this profile |
component | Σ | 0..* | BackboneElement | Not used in this profile |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. |
Documentation for this format |
Path | Conformance | ValueSet / Code |
Observation.status | required | ObservationStatus |
Observation.category | preferred | ObservationCategoryCodes |
Observation.category:clinical-test | preferred | Pattern: clinical-test |
Observation.code | extensible | Pattern: LOINC code 89247-1 |
Observation.dataAbsentReason | extensible | DataAbsentReason |
Observation.interpretation | required | LOINC LL529-9 |
Observation.bodySite | example | SNOMEDCTBodyStructures |
Observation.component.code | example | LOINCCodes (a valid code from LOINC) |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | USCoreObservationClinicalTestResultProfile | Measurements and simple assertions | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(ServiceRequest | CarePlan) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(Procedure) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. | ||||
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:clinical-test | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/core/CodeSystem/us-core-observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: clinical-test | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | SΣ | 1..1 | CodeableConcept | Clinical Test Name Binding: US Core Clinical Test Codes (extensible) Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 89247-1 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | SΣ | 1..1 | Reference(Cancer Patient Profile) | Who and/or what the observation is about | ||||
focus | ΣTU | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 0..1 | Clinically relevant time/time-period for observation | |||||
effectiveDateTime | dateTime S | |||||||
effectivePeriod | Period | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | ||||
value[x] | SΣC | 0..1 | integer | Result Value | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: LOINC Answer List LL529-9 (required) | ||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Not used in this profile Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Not used in this profile | |||||
device | 0..1 | Reference(Device | DeviceMetric) | Not used in this profile | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Not used in this profile | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
component | Σ | 0..* | BackboneElement | Not used in this profile | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | Σ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | ||||
Observation.language | preferred | CommonLanguages
| ||||
Observation.status | required | ObservationStatus | ||||
Observation.category | preferred | ObservationCategoryCodes | ||||
Observation.category:clinical-test | preferred | Pattern: clinical-test | ||||
Observation.code | extensible | Pattern: LOINC code 89247-1 | ||||
Observation.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.interpretation | required | LOINC LL529-9 | ||||
Observation.bodySite | example | SNOMEDCTBodyStructures | ||||
Observation.method | example | ObservationMethods | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodes | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodes | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC) | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodes |
This structure is derived from USCoreObservationClinicalTestResultProfile
Summary
Must-Support: 1 element
Structures
This structure refers to these other structures:
Maturity: 4
Differential View
This structure is derived from USCoreObservationClinicalTestResultProfile
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | USCoreObservationClinicalTestResultProfile | Measurements and simple assertions | |
basedOn | 0..* | Reference(ServiceRequest | CarePlan) | Fulfills plan, proposal or order | |
partOf | 0..* | Reference(Procedure) | Part of referenced event | |
code | 1..1 | CodeableConcept | Clinical Test Name Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 89247-1 | |
subject | 1..1 | Reference(Cancer Patient Profile) | Who and/or what the observation is about | |
effective[x] | 0..1 | Clinically relevant time/time-period for observation | ||
effectiveDateTime | dateTime | |||
effectivePeriod | Period | |||
value[x] | 0..1 | integer | Result Value | |
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: LOINC Answer List LL529-9 (required) |
bodySite | 0..1 | CodeableConcept | Not used in this profile | |
specimen | 0..1 | Reference(Specimen) | Not used in this profile | |
device | 0..1 | Reference(Device | DeviceMetric) | Not used in this profile | |
hasMember | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Not used in this profile | |
component | 0..* | BackboneElement | Not used in this profile | |
Documentation for this format |
Path | Conformance | ValueSet |
Observation.interpretation | required | LOINC LL529-9 |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | USCoreObservationClinicalTestResultProfile | Measurements and simple assertions |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
basedOn | Σ | 0..* | Reference(ServiceRequest | CarePlan) | Fulfills plan, proposal or order |
partOf | Σ | 0..* | Reference(Procedure) | Part of referenced event |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. |
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:clinical-test | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/core/CodeSystem/us-core-observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: clinical-test | |
code | SΣ | 1..1 | CodeableConcept | Clinical Test Name Binding: US Core Clinical Test Codes (extensible) Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 89247-1 | |
subject | SΣ | 1..1 | Reference(Cancer Patient Profile) | Who and/or what the observation is about |
effective[x] | SΣC | 0..1 | Clinically relevant time/time-period for observation | |
effectiveDateTime | dateTime | |||
value[x] | SΣC | 0..1 | integer | Result Value |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: LOINC Answer List LL529-9 (required) |
bodySite | 0..1 | CodeableConcept | Not used in this profile Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |
specimen | 0..1 | Reference(Specimen) | Not used in this profile | |
device | 0..1 | Reference(Device | DeviceMetric) | Not used in this profile | |
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Not used in this profile |
component | Σ | 0..* | BackboneElement | Not used in this profile |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. |
Documentation for this format |
Path | Conformance | ValueSet / Code |
Observation.status | required | ObservationStatus |
Observation.category | preferred | ObservationCategoryCodes |
Observation.category:clinical-test | preferred | Pattern: clinical-test |
Observation.code | extensible | Pattern: LOINC code 89247-1 |
Observation.dataAbsentReason | extensible | DataAbsentReason |
Observation.interpretation | required | LOINC LL529-9 |
Observation.bodySite | example | SNOMEDCTBodyStructures |
Observation.component.code | example | LOINCCodes (a valid code from LOINC) |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | USCoreObservationClinicalTestResultProfile | Measurements and simple assertions | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(ServiceRequest | CarePlan) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(Procedure) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. | ||||
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:clinical-test | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/us/core/CodeSystem/us-core-observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: clinical-test | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | SΣ | 1..1 | CodeableConcept | Clinical Test Name Binding: US Core Clinical Test Codes (extensible) Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 89247-1 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
subject | SΣ | 1..1 | Reference(Cancer Patient Profile) | Who and/or what the observation is about | ||||
focus | ΣTU | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 0..1 | Clinically relevant time/time-period for observation | |||||
effectiveDateTime | dateTime S | |||||||
effectivePeriod | Period | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | ||||
value[x] | SΣC | 0..1 | integer | Result Value | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: LOINC Answer List LL529-9 (required) | ||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Not used in this profile Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Not used in this profile | |||||
device | 0..1 | Reference(Device | DeviceMetric) | Not used in this profile | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Not used in this profile | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
component | Σ | 0..* | BackboneElement | Not used in this profile | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | Σ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | ||||
Observation.language | preferred | CommonLanguages
| ||||
Observation.status | required | ObservationStatus | ||||
Observation.category | preferred | ObservationCategoryCodes | ||||
Observation.category:clinical-test | preferred | Pattern: clinical-test | ||||
Observation.code | extensible | Pattern: LOINC code 89247-1 | ||||
Observation.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.interpretation | required | LOINC LL529-9 | ||||
Observation.bodySite | example | SNOMEDCTBodyStructures | ||||
Observation.method | example | ObservationMethods | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodes | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodes | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC) | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodes |
This structure is derived from USCoreObservationClinicalTestResultProfile
Summary
Must-Support: 1 element
Structures
This structure refers to these other structures:
Maturity: 4
Other representations of profile: CSV, Excel, Schematron