This page is part of the Da Vinci Data Exchange for Quality Measures (DEQM) FHIR IG (v1.0.0: STU 1) based on FHIR R3. The current version which supercedes this version is 3.1.0. For a full list of available versions, see the Directory of published versions
JSON Format: CapabilityStatement-reporter-client
Download Raw json
{ "resourceType" : "CapabilityStatement", "id" : "reporter-client", "text" : { "status" : "generated", "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><h2 id=\"title\">DaVinci DEQM Reporter Client CapabilityStatement</h2><p>This profile defines the expected capabilities of a Da Vinci DEQM Reporter Client when conforming to the Da Vinci DEQM Implementation Guide. Reporters include systems that are primary reporters of patient healthcare information and systems that consume data from Producers. This CapabilityStatement resource includes the complete list of the *recommended* Da Vinci DEQM profiles and RESTful operations that a Da Vinci DEQM Reporter Client could support. Clients have the option of choosing from this list based on their local use cases and other contextual requirements.</p><ul><li>FHIR Version: 3.0.2</li><li>Supported formats: xml, json</li><li>Published: 2019-03-14</li><li>Published by: The DaVinci Project</li></ul><h3 id=\"igs\" class=\"no_toc\">Implementation guides that SHOULD be supported:</h3><li>http://hl7.org/fhir/us/qicore/ImplementationGuide/us-qicore-3.2.0</li><li>http://hl7.org/fhir/us/cqfmeasures/ImplementationGuide/hl7.fhir.us.cqfmeasures</li><h3 id=\"behavior\">FHIR RESTful Capabilities</h3><p>Da Vinci DEQM Producer Client <strong>SHALL</strong></p><ol><li>Support at least one transaction defined in the <em>Framework</em> Section of this Implementation Guide.</li></ol><p id=\"security\"><strong>Security:</strong></p><p>For general security consideration refer to the <a href=\"http://build.fhir.org/secpriv-module.html\">Security and Privacy Considerations</a>.</p><h3 id=\"resource--details\" class=\"no_toc\">RESTful Capabilities by Resource/Profile:</h3><p><strong>Summary of Search Criteria</strong></p><table class=\"grid\"><thead><tr><th>Resource Type</th><th>Supported Profiles</th><th>Supported Searches</th><th>Supported Includes</th></tr></thead><tbody><tr><td><a href=\"#measurereport\">MeasureReport</a></td><td><p><a href=\"./StructureDefinition-summary-measurereport-deqm.html\">DEQM Summary MeasureReport Profile</a>, <a href=\"./StructureDefinition-indv-measurereport-deqm.html\">DEQM Individual MeasureReport Profile</a></p></td><td>\n\t\t\t\t\t\t\t\n\t\t\t\t\t\t</td><td>\n\t\t\t\t\t\t\t\n\t\t\t\t\t\t</td></tr></tbody></table><br/><h4 id=\"measurereport\" class=\"no_toc\">MeasureReport</h4><p>Supported Profiles:\n\t\t\t<p><a href=\"./StructureDefinition-summary-measurereport-deqm.html\">DEQM Summary MeasureReport Profile</a>, <a href=\"./StructureDefinition-indv-measurereport-deqm.html\">DEQM Individual MeasureReport Profile</a></p>\n\n\t\t\t\t</p><p>The DaVinci DEQM Reporter Client <strong>SHOULD</strong> be capable of supporting the DEQM MeasureReport Profiles and all the DEQM, CQFM and QI Core Profiles they reference.</p><p>Profile Interaction Summary:</p><ul><li><strong>SHOULD</strong> support \n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<code>create</code>.</li></ul><br/></div>" }, "url" : "http://hl7.org/fhir/us/davinci-deqm/CapabilityStatement/reporter-client", "version" : "1.0.0", "name" : "reporter_client", "title" : "DaVinci DEQM Reporter Client CapabilityStatement", "status" : "active", "experimental" : false, "date" : "2019-03-14T00:00:00+00:00", "publisher" : "The DaVinci Project", "contact" : [ { "telecom" : [ { "system" : "url", "value" : "http://www.hl7.org/Special/committees/cqi/index.cfm" } ] } ], "description" : "This profile defines the expected capabilities of a Da Vinci DEQM Reporter Client when conforming to the Da Vinci DEQM Implementation Guide. Reporters include systems that are primary reporters of patient healthcare information and systems that consume data from Producers. This CapabilityStatement resource includes the complete list of the *recommended* Da Vinci DEQM profiles and RESTful operations that a Da Vinci DEQM Reporter Client could support. Clients have the option of choosing from this list based on their local use cases and other contextual requirements.", "jurisdiction" : [ { "coding" : [ { "system" : "urn:iso:std:iso:3166", "code" : "US", "display" : "United States of America" } ] } ], "kind" : "requirements", "fhirVersion" : "3.0.2", "acceptUnknown" : "both", "format" : [ "xml", "json" ], "patchFormat" : [ "application/json-patch+json" ], "implementationGuide" : [ "http://hl7.org/fhir/us/davinci-deqm/ImplementationGuide/hl7.fhir.us.davinci-deqm-1.0.0", "http://hl7.org/fhir/us/qicore/ImplementationGuide/us-qicore-3.2.0", "http://hl7.org/fhir/us/cqfmeasures/ImplementationGuide/hl7.fhir.us.cqfmeasures" ], "profile" : [ { "extension" : [ { "url" : "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation", "valueCode" : "SHALL" } ], "reference" : "http://hl7.org/fhir/us/davinci-deqm/StructureDefinition/devicerequest-deqm", "display" : "DEQM DeviceRequest Profile" }, { "extension" : [ { "url" : "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation", "valueCode" : "SHALL" } ], "reference" : "http://hl7.org/fhir/us/davinci-deqm/StructureDefinition/medicationadministration-deqm", "display" : "DEQM MedicationAdministration Profile" }, { "extension" : [ { "url" : "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation", "valueCode" : "SHALL" } ], "reference" : "http://hl7.org/fhir/us/davinci-deqm/StructureDefinition/summary-measurereport-deqm", "display" : "DEQM Summary MeasureReport Profile" }, { "extension" : [ { "url" : "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation", "valueCode" : "SHALL" } ], "reference" : "http://hl7.org/fhir/us/davinci-deqm/StructureDefinition/practitioner-deqm", "display" : "DEQM Practitioner Profile" }, { "extension" : [ { "url" : "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation", "valueCode" : "SHALL" } ], "reference" : "http://hl7.org/fhir/us/davinci-deqm/StructureDefinition/deviceusestatement-deqm", "display" : "DEQM DeviceUseStatement Profile" }, { "extension" : [ { "url" : "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation", "valueCode" : "SHALL" } ], "reference" : "http://hl7.org/fhir/us/davinci-deqm/StructureDefinition/organization-deqm", "display" : "DEQM Organization Profile" }, { "extension" : [ { "url" : "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation", "valueCode" : "SHALL" } ], "reference" : "http://hl7.org/fhir/us/davinci-deqm/StructureDefinition/coverage-deqm", "display" : "DEQM Coverage Profile" }, { "extension" : [ { "url" : "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation", "valueCode" : "SHALL" } ], "reference" : "http://hl7.org/fhir/us/davinci-deqm/StructureDefinition/indv-measurereport-deqm", "display" : "DEQM Individual MeasureReport Profile" }, { "extension" : [ { "url" : "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation", "valueCode" : "SHALL" } ], "reference" : "http://hl7.org/fhir/us/davinci-deqm/StructureDefinition/medicationrequest-deqm", "display" : "DEQM MedicationRequest Profile" } ], "rest" : [ { "mode" : "client", "documentation" : "Da Vinci DEQM Producer Client **SHALL**\n\n1. Support at least one transaction defined in the *Framework* Section of this Implementation Guide.", "security" : { "description" : "For general security consideration refer to the [Security and Privacy Considerations](http://build.fhir.org/secpriv-module.html)." }, "resource" : [ { "extension" : [ { "url" : "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation", "valueCode" : "SHOULD" } ], "type" : "MeasureReport", "documentation" : "The DaVinci DEQM Reporter Client **SHOULD** be capable of supporting the DEQM MeasureReport Profiles and all the DEQM, CQFM and QI Core Profiles they reference.", "interaction" : [ { "extension" : [ { "url" : "http://hl7.org/fhir/StructureDefinition/capabilitystatement-expectation", "valueCode" : "SHOULD" } ], "code" : "create" } ], "readHistory" : false, "updateCreate" : false } ] } ] }