Data Exchange For Quality Measures STU1 for FHIR STU3 Implementation Guide (Release 1.0.0)

This page is part of the Da Vinci Data Exchange for Quality Measures (DEQM) FHIR IG (v1.0.0: STU 1) based on FHIR R3. The current version which supercedes this version is 3.1.0. For a full list of available versions, see the Directory of published versions

Downloads: CapabilityStatement: (XML, JSON),OpenAPI-Swagger Definition file

DaVinci DEQM Producer Server CapabilityStatement

This profile defines the expected capabilities of a Da Vinci DEQM Producer Server when conforming to the Da Vinci DEQM Implementation Guide. Producers include systems that are primary producers of patient healthcare information. This CapabilityStatement resource includes the complete list of the *recommended* Da Vinci DEQM profiles and RESTful operations that a Da Vinci DEQM Producer Server could support. Servers have the option of choosing from this list based on their local use cases and other contextual requirements.

  • FHIR Version: 3.0.2
  • Supported formats: xml, json
  • Published: 2019-10-01
  • Published by: The DaVinci Project

FHIR RESTful Capabilities

Da Vinci DEQM Producer Server SHALL

  1. Support at least one transaction defined in the Framework Section of this Implementation Guide.
  2. Declare a CapabilityStatement identifying the list of supported profiles and operations.
  3. Implement the RESTful behavior according to the FHIR specification including returning the appropriate response classes as described in the FHIR specification for FHIR RESTful API.
  4. Support both xml and json resource formats for all interactions.

Security:

For general security consideration refer to the Security and Privacy Considerations.

RESTful Capabilities by Resource/Profile:

Summary of Operations

  • SHALL support the $collect-data operation.