This page is part of the US Core (v6.0.0: STU6) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry | Version: 6.0.0 | |||
Active as of 2022-04-20 | Computable Name: USCorePulseOximetryProfile | |||
Copyright/Legal: Used by permission of HL7 International, all rights reserved Creative Commons License |
To promote interoperability and adoption through common implementation, this profile sets minimum expectations for the Observation resource to record, search, and fetch pulse oximetry and inspired oxygen observations with a standard LOINC codes and UCUM units of measure. It is based on the US Core Vital Signs Profile and identifies which additional core elements, extensions, vocabularies, and value sets SHALL be present and constrains the way the elements are used when using the profile. It provides the floor for standards development for specific use cases.
Example Usage Scenarios:
The following are example usage scenarios for this profile:
In addition to the Mandatory and Must Support data elements in the US Core Vital Signs Profile, the following data-elements must always be present (Mandatory definition) or must be supported if the data is present in the sending system (Must Support definition). They are presented below in a simple human-readable explanation. Profile specific guidance and examples are provided as well. The Formal Views below provides the formal summary, definitions, and terminology requirements.
Each Observation Must Have:
Each Observation Must Support:
*see guidance below
Profile Specific Implementation Guidance:
a code system value SHOULD be supplied for each additional code.
Observation.hasMember
.
Observation.dataAbsentReason
.Observation.component
without a value, SHALL include a reason why the data is absent.
Observation.component.dataAbsentReason
.Implementers may use this profile as a base for other vital signs in addition to those in this guide.
L/min
for Observation.component.value(x)
. This is a known issue in and it means validation errors may occur when validating against this version of the US Core Pulse Oximetry Profile. A change request to correct this has been applied to the base FHIR ver 4.3.0 (“Release 4B”).Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from USCoreVitalSignsProfile
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | USCoreVitalSignsProfile | US Core Pulse Oximetry Profile | |
code | S | 1..1 | CodeableConcept | (USCDI) Oxygen Saturation by Pulse Oximetry |
Slices for coding | S | 0..* | Coding | (USCDI) Code defined by a terminology system Slice: Unordered, Open by pattern:$this |
coding:PulseOx | S | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 59408-5 | |
coding:O2Sat | S | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 2708-6 | |
valueQuantity | S | 0..1 | Quantity | (USCDI) Oxygen Saturation by Pulse Oximetry Value |
value | S | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
unit | S | 1..1 | string | (USCDI) Unit representation |
system | S | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % |
Slices for component | S | 0..* | BackboneElement | (USCDI) Used when reporting flow rates or oxygen concentration. Slice: Unordered, Open by pattern:code |
component:FlowRate | S | 0..1 | BackboneElement | (USCDI) Inhaled oxygen flow rate |
code | S | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3151-8 | |
valueQuantity | S | 0..1 | Quantity S | (USCDI) Vital Sign Component Value |
value | S | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
unit | S | 1..1 | string | (USCDI) Unit representation |
system | S | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: L/min |
component:Concentration | S | 0..1 | BackboneElement | (USCDI) Inhaled oxygen concentration |
code | S | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3150-0 | |
valueQuantity | S | 0..1 | Quantity S | (USCDI) Vital Sign Component Value |
value | S | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
unit | S | 1..1 | string | (USCDI) Unit representation |
system | S | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | USCoreVitalSignsProfile | US Core Pulse Oximetry Profile |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | (USCDI) registered | preliminary | final | amended + Binding: ObservationStatus (required) |
Slices for category | S | 1..* | CodeableConcept | (USCDI) Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:VSCat | S | 1..1 | CodeableConcept | (USCDI) Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
coding | SΣ | 1..* | Coding | (USCDI) Code defined by a terminology system |
system | SΣ | 1..1 | uri | (USCDI) Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
code | SΣ | 1..1 | code | (USCDI) Symbol in syntax defined by the system Fixed Value: vital-signs |
code | SΣ | 1..1 | CodeableConcept | (USCDI) Oxygen Saturation by Pulse Oximetry Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. |
Slices for coding | SΣ | 0..* | Coding | (USCDI) Code defined by a terminology system Slice: Unordered, Open by pattern:$this |
coding:PulseOx | SΣ | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 59408-5 | |
coding:O2Sat | SΣ | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 2708-6 | |
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | (USCDI) Who and/or what the observation is about |
effective[x] | SΣC | 1..1 | (USCDI) Often just a dateTime for Vital Signs | |
effectiveDateTime | dateTime | |||
Slices for value[x] | SΣC | 0..1 | (USCDI) Vital Signs Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
valueQuantity | Quantity | |||
value[x]:valueQuantity | SΣC | 0..1 | Quantity | (USCDI) Oxygen Saturation by Pulse Oximetry Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | (USCDI) Unit representation |
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % |
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
Slices for component | SΣC | 0..* | BackboneElement | (USCDI) Used when reporting flow rates or oxygen concentration. Slice: Unordered, Open by pattern:code |
component:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. |
value[x] | SΣC | 0..1 | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
valueQuantity | Quantity | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
component:FlowRate | SΣC | 0..1 | BackboneElement | (USCDI) Inhaled oxygen flow rate |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3151-8 | |
value[x] | SΣC | 0..1 | Quantity | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | (USCDI) Unit representation |
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: L/min |
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
component:Concentration | SΣC | 0..1 | BackboneElement | (USCDI) Inhaled oxygen concentration |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3150-0 | |
value[x] | SΣC | 0..1 | Quantity | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | (USCDI) Unit representation |
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % |
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
Documentation for this format |
Path | Conformance | ValueSet / Code |
Observation.status | required | ObservationStatus |
Observation.category | preferred | ObservationCategoryCodes |
Observation.category:VSCat | preferred | ObservationCategoryCodes |
Observation.code | extensible | UsCoreVitalSigns |
Observation.value[x] | extensible | VitalSignsUnits |
Observation.value[x]:valueQuantity | extensible | VitalSignsUnits |
Observation.value[x]:valueQuantity.comparator | required | QuantityComparator |
Observation.dataAbsentReason | extensible | DataAbsentReason |
Observation.component.code | extensible | UsCoreVitalSigns |
Observation.component.value[x] | extensible | VitalSignsUnits |
Observation.component.dataAbsentReason | extensible | DataAbsentReason |
Observation.component:FlowRate.code | extensible | Pattern: LOINC code 3151-8 |
Observation.component:FlowRate.value[x] | extensible | VitalSignsUnits |
Observation.component:FlowRate.value[x].comparator | required | QuantityComparator |
Observation.component:FlowRate.dataAbsentReason | extensible | DataAbsentReason |
Observation.component:Concentration.code | extensible | Pattern: LOINC code 3150-0 |
Observation.component:Concentration.value[x] | extensible | VitalSignsUnits |
Observation.component:Concentration.value[x].comparator | required | QuantityComparator |
Observation.component:Concentration.dataAbsentReason | extensible | DataAbsentReason |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : ($this as dateTime).toString().length() >= 8 | |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component, Observation.component:FlowRate, Observation.component:Concentration | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | USCoreVitalSignsProfile | US Core Pulse Oximetry Profile | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | (USCDI) registered | preliminary | final | amended + Binding: ObservationStatus (required) | ||||
Slices for category | S | 1..* | CodeableConcept | (USCDI) Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:VSCat | S | 1..1 | CodeableConcept | (USCDI) Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
coding | SΣ | 1..* | Coding | (USCDI) Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | SΣ | 1..1 | uri | (USCDI) Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | SΣ | 1..1 | code | (USCDI) Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
code | SΣ | 1..1 | CodeableConcept | (USCDI) Oxygen Saturation by Pulse Oximetry Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | SΣ | 0..* | Coding | (USCDI) Code defined by a terminology system Slice: Unordered, Open by pattern:$this | ||||
coding:PulseOx | SΣ | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 59408-5 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
coding:O2Sat | SΣ | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 2708-6 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | (USCDI) Who and/or what the observation is about | ||||
focus | ΣTU | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 1..1 | (USCDI) Often just a dateTime for Vital Signs | |||||
effectiveDateTime | dateTime S | |||||||
effectivePeriod | Period | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | ||||
Slices for value[x] | SΣC | 0..1 | (USCDI) Vital Signs Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
valueQuantity | Quantity S | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
value[x]:valueQuantity | SΣC | 0..1 | Quantity | (USCDI) Oxygen Saturation by Pulse Oximetry Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | (USCDI) Unit representation | ||||
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | ||||
Slices for component | SΣC | 0..* | BackboneElement | (USCDI) Used when reporting flow rates or oxygen concentration. Slice: Unordered, Open by pattern:code | ||||
component:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. | ||||
value[x] | SΣC | 0..1 | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
valueQuantity | Quantity S | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:FlowRate | SΣC | 0..1 | BackboneElement | (USCDI) Inhaled oxygen flow rate | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3151-8 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | SΣC | 0..1 | Quantity S | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | (USCDI) Unit representation | ||||
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: L/min | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:Concentration | SΣC | 0..1 | BackboneElement | (USCDI) Inhaled oxygen concentration | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3150-0 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | SΣC | 0..1 | Quantity S | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | (USCDI) Unit representation | ||||
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | ||||
Observation.language | preferred | CommonLanguages
| ||||
Observation.status | required | ObservationStatus | ||||
Observation.category | preferred | ObservationCategoryCodes | ||||
Observation.category:VSCat | preferred | ObservationCategoryCodes | ||||
Observation.code | extensible | UsCoreVitalSigns | ||||
Observation.value[x] | extensible | VitalSignsUnits | ||||
Observation.value[x]:valueQuantity | extensible | VitalSignsUnits | ||||
Observation.value[x]:valueQuantity.comparator | required | QuantityComparator | ||||
Observation.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.bodySite | example | SNOMEDCTBodyStructures | ||||
Observation.method | example | ObservationMethods | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodes | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodes | ||||
Observation.component.code | extensible | UsCoreVitalSigns | ||||
Observation.component.value[x] | extensible | VitalSignsUnits | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.component:FlowRate.code | extensible | Pattern: LOINC code 3151-8 | ||||
Observation.component:FlowRate.value[x] | extensible | VitalSignsUnits | ||||
Observation.component:FlowRate.value[x].comparator | required | QuantityComparator | ||||
Observation.component:FlowRate.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component:FlowRate.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.component:Concentration.code | extensible | Pattern: LOINC code 3150-0 | ||||
Observation.component:Concentration.value[x] | extensible | VitalSignsUnits | ||||
Observation.component:Concentration.value[x].comparator | required | QuantityComparator | ||||
Observation.component:Concentration.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component:Concentration.interpretation | extensible | ObservationInterpretationCodes |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : ($this as dateTime).toString().length() >= 8 | |
vs-3 | error | Observation.component, Observation.component:FlowRate, Observation.component:Concentration | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
This structure is derived from USCoreVitalSignsProfile
Summary
Mandatory: 2 elements (12 nested mandatory elements)
Must-Support: 24 elements
Fixed Value: 6 elements
Slices
This structure defines the following Slices:
Differential View
This structure is derived from USCoreVitalSignsProfile
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | USCoreVitalSignsProfile | US Core Pulse Oximetry Profile | |
code | S | 1..1 | CodeableConcept | (USCDI) Oxygen Saturation by Pulse Oximetry |
Slices for coding | S | 0..* | Coding | (USCDI) Code defined by a terminology system Slice: Unordered, Open by pattern:$this |
coding:PulseOx | S | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 59408-5 | |
coding:O2Sat | S | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 2708-6 | |
valueQuantity | S | 0..1 | Quantity | (USCDI) Oxygen Saturation by Pulse Oximetry Value |
value | S | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
unit | S | 1..1 | string | (USCDI) Unit representation |
system | S | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % |
Slices for component | S | 0..* | BackboneElement | (USCDI) Used when reporting flow rates or oxygen concentration. Slice: Unordered, Open by pattern:code |
component:FlowRate | S | 0..1 | BackboneElement | (USCDI) Inhaled oxygen flow rate |
code | S | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3151-8 | |
valueQuantity | S | 0..1 | Quantity S | (USCDI) Vital Sign Component Value |
value | S | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
unit | S | 1..1 | string | (USCDI) Unit representation |
system | S | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: L/min |
component:Concentration | S | 0..1 | BackboneElement | (USCDI) Inhaled oxygen concentration |
code | S | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3150-0 | |
valueQuantity | S | 0..1 | Quantity S | (USCDI) Vital Sign Component Value |
value | S | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
unit | S | 1..1 | string | (USCDI) Unit representation |
system | S | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | S | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % |
Documentation for this format |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | USCoreVitalSignsProfile | US Core Pulse Oximetry Profile |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | (USCDI) registered | preliminary | final | amended + Binding: ObservationStatus (required) |
Slices for category | S | 1..* | CodeableConcept | (USCDI) Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:VSCat | S | 1..1 | CodeableConcept | (USCDI) Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
coding | SΣ | 1..* | Coding | (USCDI) Code defined by a terminology system |
system | SΣ | 1..1 | uri | (USCDI) Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
code | SΣ | 1..1 | code | (USCDI) Symbol in syntax defined by the system Fixed Value: vital-signs |
code | SΣ | 1..1 | CodeableConcept | (USCDI) Oxygen Saturation by Pulse Oximetry Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. |
Slices for coding | SΣ | 0..* | Coding | (USCDI) Code defined by a terminology system Slice: Unordered, Open by pattern:$this |
coding:PulseOx | SΣ | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 59408-5 | |
coding:O2Sat | SΣ | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 2708-6 | |
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | (USCDI) Who and/or what the observation is about |
effective[x] | SΣC | 1..1 | (USCDI) Often just a dateTime for Vital Signs | |
effectiveDateTime | dateTime | |||
Slices for value[x] | SΣC | 0..1 | (USCDI) Vital Signs Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
valueQuantity | Quantity | |||
value[x]:valueQuantity | SΣC | 0..1 | Quantity | (USCDI) Oxygen Saturation by Pulse Oximetry Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | (USCDI) Unit representation |
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % |
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
Slices for component | SΣC | 0..* | BackboneElement | (USCDI) Used when reporting flow rates or oxygen concentration. Slice: Unordered, Open by pattern:code |
component:All Slices | Content/Rules for all slices | |||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. |
value[x] | SΣC | 0..1 | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
valueQuantity | Quantity | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
component:FlowRate | SΣC | 0..1 | BackboneElement | (USCDI) Inhaled oxygen flow rate |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3151-8 | |
value[x] | SΣC | 0..1 | Quantity | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | (USCDI) Unit representation |
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: L/min |
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
component:Concentration | SΣC | 0..1 | BackboneElement | (USCDI) Inhaled oxygen concentration |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3150-0 | |
value[x] | SΣC | 0..1 | Quantity | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | (USCDI) Unit representation |
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % |
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
Documentation for this format |
Path | Conformance | ValueSet / Code |
Observation.status | required | ObservationStatus |
Observation.category | preferred | ObservationCategoryCodes |
Observation.category:VSCat | preferred | ObservationCategoryCodes |
Observation.code | extensible | UsCoreVitalSigns |
Observation.value[x] | extensible | VitalSignsUnits |
Observation.value[x]:valueQuantity | extensible | VitalSignsUnits |
Observation.value[x]:valueQuantity.comparator | required | QuantityComparator |
Observation.dataAbsentReason | extensible | DataAbsentReason |
Observation.component.code | extensible | UsCoreVitalSigns |
Observation.component.value[x] | extensible | VitalSignsUnits |
Observation.component.dataAbsentReason | extensible | DataAbsentReason |
Observation.component:FlowRate.code | extensible | Pattern: LOINC code 3151-8 |
Observation.component:FlowRate.value[x] | extensible | VitalSignsUnits |
Observation.component:FlowRate.value[x].comparator | required | QuantityComparator |
Observation.component:FlowRate.dataAbsentReason | extensible | DataAbsentReason |
Observation.component:Concentration.code | extensible | Pattern: LOINC code 3150-0 |
Observation.component:Concentration.value[x] | extensible | VitalSignsUnits |
Observation.component:Concentration.value[x].comparator | required | QuantityComparator |
Observation.component:Concentration.dataAbsentReason | extensible | DataAbsentReason |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : ($this as dateTime).toString().length() >= 8 | |
vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
vs-3 | error | Observation.component, Observation.component:FlowRate, Observation.component:Concentration | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | USCoreVitalSignsProfile | US Core Pulse Oximetry Profile | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | (USCDI) registered | preliminary | final | amended + Binding: ObservationStatus (required) | ||||
Slices for category | S | 1..* | CodeableConcept | (USCDI) Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:VSCat | S | 1..1 | CodeableConcept | (USCDI) Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
coding | SΣ | 1..* | Coding | (USCDI) Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | SΣ | 1..1 | uri | (USCDI) Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | SΣ | 1..1 | code | (USCDI) Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
code | SΣ | 1..1 | CodeableConcept | (USCDI) Oxygen Saturation by Pulse Oximetry Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | SΣ | 0..* | Coding | (USCDI) Code defined by a terminology system Slice: Unordered, Open by pattern:$this | ||||
coding:PulseOx | SΣ | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 59408-5 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
coding:O2Sat | SΣ | 1..1 | Coding | (USCDI) Code defined by a terminology system Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 2708-6 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | (USCDI) Who and/or what the observation is about | ||||
focus | ΣTU | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 1..1 | (USCDI) Often just a dateTime for Vital Signs | |||||
effectiveDateTime | dateTime S | |||||||
effectivePeriod | Period | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | ||||
Slices for value[x] | SΣC | 0..1 | (USCDI) Vital Signs Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
valueQuantity | Quantity S | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
value[x]:valueQuantity | SΣC | 0..1 | Quantity | (USCDI) Oxygen Saturation by Pulse Oximetry Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | (USCDI) Unit representation | ||||
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | ||||
Slices for component | SΣC | 0..* | BackboneElement | (USCDI) Used when reporting flow rates or oxygen concentration. Slice: Unordered, Open by pattern:code | ||||
component:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. | ||||
value[x] | SΣC | 0..1 | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
valueQuantity | Quantity S | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:FlowRate | SΣC | 0..1 | BackboneElement | (USCDI) Inhaled oxygen flow rate | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3151-8 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | SΣC | 0..1 | Quantity S | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | (USCDI) Unit representation | ||||
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: L/min | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
component:Concentration | SΣC | 0..1 | BackboneElement | (USCDI) Inhaled oxygen concentration | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | (USCDI) Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 3150-0 | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
value[x] | SΣC | 0..1 | Quantity S | (USCDI) Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | (USCDI) Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | (USCDI) Unit representation | ||||
system | SΣC | 1..1 | uri | (USCDI) System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | (USCDI) Coded form of the unit Fixed Value: % | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | ||||
Observation.language | preferred | CommonLanguages
| ||||
Observation.status | required | ObservationStatus | ||||
Observation.category | preferred | ObservationCategoryCodes | ||||
Observation.category:VSCat | preferred | ObservationCategoryCodes | ||||
Observation.code | extensible | UsCoreVitalSigns | ||||
Observation.value[x] | extensible | VitalSignsUnits | ||||
Observation.value[x]:valueQuantity | extensible | VitalSignsUnits | ||||
Observation.value[x]:valueQuantity.comparator | required | QuantityComparator | ||||
Observation.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.bodySite | example | SNOMEDCTBodyStructures | ||||
Observation.method | example | ObservationMethods | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodes | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodes | ||||
Observation.component.code | extensible | UsCoreVitalSigns | ||||
Observation.component.value[x] | extensible | VitalSignsUnits | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.component:FlowRate.code | extensible | Pattern: LOINC code 3151-8 | ||||
Observation.component:FlowRate.value[x] | extensible | VitalSignsUnits | ||||
Observation.component:FlowRate.value[x].comparator | required | QuantityComparator | ||||
Observation.component:FlowRate.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component:FlowRate.interpretation | extensible | ObservationInterpretationCodes | ||||
Observation.component:Concentration.code | extensible | Pattern: LOINC code 3150-0 | ||||
Observation.component:Concentration.value[x] | extensible | VitalSignsUnits | ||||
Observation.component:Concentration.value[x].comparator | required | QuantityComparator | ||||
Observation.component:Concentration.dataAbsentReason | extensible | DataAbsentReason | ||||
Observation.component:Concentration.interpretation | extensible | ObservationInterpretationCodes |
Id | Grade | Path(s) | Details | Requirements |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : ($this as dateTime).toString().length() >= 8 | |
vs-3 | error | Observation.component, Observation.component:FlowRate, Observation.component:Concentration | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
This structure is derived from USCoreVitalSignsProfile
Summary
Mandatory: 2 elements (12 nested mandatory elements)
Must-Support: 24 elements
Fixed Value: 6 elements
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron
Below is an overview of the required Server RESTful FHIR interactions for this profile - for example, search and read operations - when supporting the US Core interactions to access this profile’s information (Profile Support + Interaction Support). Note that systems that support only US Core Profiles (Profile Only Support) are not required to support these interactions. See the US Core Server CapabilityStatement for a complete list of supported RESTful interactions for this IG.
The syntax used to describe the interactions is described here.
patient/Observation.rs
)patient.Observation.rs?category=http://terminology.hl7.org/CodeSystem/observation-category|vital-signs
).The following search parameters and search parameter combinations SHALL be supported:
SHALL support searching using the combination of the patient
and category
search parameters:
GET [base]/Observation?patient={Type/}[id]&category=http://terminology.hl7.org/CodeSystem/observation-category|vital-signs
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and a category code = vital-signs
(how to search by reference and how to search by token)
patient
and code
search parameters:
code
(e.g.code={system|}[code],{system|}[code],...
)GET [base]/Observation?patient={Type/}[id]&code={system|}[code]{,{system|}[code],...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and observation code(s). SHOULD support search by multiple codes. The Observation code
parameter searches `Observation.code only. (how to search by reference and how to search by token)
patient
and category
and date
search parameters:
date
comparators: gt,lt,ge,le
date
(e.g.date=[date]&date=[date]]&...
)GET [base]/Observation?patient={Type/}[id]&category=http://terminology.hl7.org/CodeSystem/observation-category|vital-signs&date={gt|lt|ge|le}[date]{&date={gt|lt|ge|le}[date]&...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and date and a category code = vital-signs
(how to search by reference and how to search by token and how to search by date)
The following search parameter combinations SHOULD be supported:
patient
and category
and status
search parameters:
status
(e.g.status={system|}[code],{system|}[code],...
)GET [base]/Observation?patient={Type/}[id]&category=http://terminology.hl7.org/CodeSystem/observation-category|vital-signs&status={system|}[code]{,{system|}[code],...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and category and status (how to search by reference and how to search by token)
patient
and code
and date
search parameters:
code
(e.g.code={system|}[code],{system|}[code],...
)date
comparators: gt,lt,ge,le
date
(e.g.date=[date]&date=[date]]&...
)GET [base]/Observation?patient={Type/}[id]&code={system|}[code]{,{system|}[code],...}&date={gt|lt|ge|le}[date]{&date={gt|lt|ge|le}[date]&...}
Example:
Implementation Notes: Fetches a bundle of all Observation resources for the specified patient and date and report code(s). SHOULD support search by multiple codes. (how to search by reference and how to search by token and how to search by date)