This page is part of the US Core (v7.0.0-ballot: STU7 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 6.1.0. For a full list of available versions, see the Directory of published versions
Page standards status: Trial-use | Maturity Level: 3 |
Definitions for the us-core-implantable-device resource profile.
Guidance on how to interpret the contents of this table can be found here
0. Device | |
Definition | - |
Comments | - |
Must Support | false |
2. Device.udiCarrier | |
Comments | Some devices may not have UDI information (for example. historical data or patient reported data). |
Control | 0..1 |
Must Support | true |
4. Device.udiCarrier.deviceIdentifier | |
Control | 1..? |
Must Support | true |
6. Device.udiCarrier.carrierHRF | |
Must Support | true |
Alternate Names | UDI, Barcode String |
8. Device.distinctIdentifier | |
Must Support | true |
10. Device.manufactureDate | |
Must Support | true |
12. Device.expirationDate | |
Must Support | true |
14. Device.lotNumber | |
Must Support | true |
16. Device.serialNumber | |
Must Support | true |
18. Device.type | |
Control | 1..? |
Binding | Unless not suitable, these codes SHALL be taken from FHIRDeviceTypes Codes to identify medical devices |
Must Support | true |
20. Device.patient | |
Control | 1..? |
Type | Reference(US Core Patient Profile) |
Must Support | true |
Guidance on how to interpret the contents of this table can be found here
0. Device | |
Definition | - A type of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device. |
Short | Item used in healthcare |
Comments | - |
Control | 0..* |
Is Modifier | false |
Must Support | false |
Summary | false |
Invariants | dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty()) dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()) dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()) dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty()) dom-6: A resource should have narrative for robust management (text.`div`.exists()) |
2. Device.implicitRules | |
Definition | A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc. |
Short | A set of rules under which this content was created |
Comments | Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc. |
Control | 0..1 |
Type | uri |
Is Modifier | true because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Summary | true |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
4. Device.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them |
Summary | false |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists()) |
6. Device.udiCarrier | |
Definition | Unique device identifier (UDI) assigned to device label or package. Note that the Device may include multiple udiCarriers as it either may include just the udiCarrier for the jurisdiction it is sold, or for multiple jurisdictions it could have been sold. |
Short | Unique Device Identifier (UDI) Barcode string |
Comments | Some devices may not have UDI information (for example. historical data or patient reported data). UDI may identify an unique instance of a device, or it may only identify the type of the device. See UDI mappings for a complete mapping of UDI parts to Device. |
Control | 0..1* |
Type | BackboneElement |
Is Modifier | false |
Must Support | true |
Summary | true |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
8. Device.udiCarrier.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Short | Extensions that cannot be ignored even if unrecognized |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Control | 0..* |
Type | Extension |
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them |
Summary | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists()) |
10. Device.udiCarrier.deviceIdentifier | |
Definition | The device identifier (DI) is a mandatory, fixed portion of a UDI that identifies the labeler and the specific version or model of a device. |
Short | Mandatory fixed portion of UDI |
Control | 10..1 |
Type | string |
Is Modifier | false |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Must Support | true |
Summary | true |
Alternate Names | DI |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
12. Device.udiCarrier.carrierHRF | |
Definition | The full UDI carrier as the human readable form (HRF) representation of the barcode string as printed on the packaging of the device. |
Short | UDI Human Readable Barcode String |
Comments | If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label. |
Control | 0..1 |
Type | string |
Is Modifier | false |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Must Support | true |
Summary | true |
Alternate Names | Human Readable Form, UDI, Barcode String |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
14. Device.status | |
Definition | Status of the Device availability. |
Short | active | inactive | entered-in-error | unknown |
Comments | This element is labeled as a modifier because the status contains the codes inactive and entered-in-error that mark the device (record)as not currently valid. |
Control | 0..1 |
Binding | The codes SHALL be taken from FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 The availability status of the device. |
Type | code |
Is Modifier | true because This element is labelled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Summary | true |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
16. Device.distinctIdentifier | |
Definition | The distinct identification string as required by regulation for a human cell, tissue, or cellular and tissue-based product. |
Short | The distinct identification string |
Comments | For example, this applies to devices in the United States regulated under Code of Federal Regulation 21CFR§1271.290(c). |
Control | 0..1 |
Type | string |
Is Modifier | false |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Must Support | true |
Summary | false |
Alternate Names | Distinct Identification Code (DIC) |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
18. Device.manufactureDate | |
Definition | The date and time when the device was manufactured. |
Short | Date when the device was made |
Control | 0..1 |
Type | dateTime |
Is Modifier | false |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Must Support | true |
Summary | false |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
20. Device.expirationDate | |
Definition | The date and time beyond which this device is no longer valid or should not be used (if applicable). |
Short | Date and time of expiry of this device (if applicable) |
Control | 0..1 |
Type | dateTime |
Is Modifier | false |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Must Support | true |
Summary | false |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
22. Device.lotNumber | |
Definition | Lot number assigned by the manufacturer. |
Short | Lot number of manufacture |
Control | 0..1 |
Type | string |
Is Modifier | false |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Must Support | true |
Summary | false |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
24. Device.serialNumber | |
Definition | The serial number assigned by the organization when the device was manufactured. |
Short | Serial number assigned by the manufacturer |
Comments | Alphanumeric Maximum 20. |
Control | 0..1 |
Type | string |
Is Modifier | false |
Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
Must Support | true |
Summary | false |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
26. Device.type | |
Definition | The kind or type of device. |
Short | The kind or type of device |
Control | 10..1 |
Binding | Unless not suitable, these codes SHALL be taken from For example codes, see FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-type Codes to identify medical devices Codes to identify medical devices. |
Type | CodeableConcept |
Is Modifier | false |
Must Support | true |
Summary | false |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
28. Device.patient | |
Definition | Patient information, If the device is affixed to a person. |
Short | Patient to whom Device is affixed |
Control | 10..1 |
Type | Reference(US Core Patient Profile, Patient) |
Is Modifier | false |
Must Support | true |
Summary | false |
Requirements | If the device is implanted in a patient, then need to associate the device to the patient. |
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count())) |
Guidance on how to interpret the contents of this table can be found here
0. Device | |||||
Definition | - | ||||
Short | Item used in healthcare | ||||
Comments | - | ||||
Control | 0..* | ||||
Is Modifier | false | ||||
Must Support | false | ||||
Summary | false | ||||
Invariants | dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty() )dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource ( contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() )dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated ( contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() )dom-5: If a resource is contained in another resource, it SHALL NOT have a security label ( contained.meta.security.empty() )dom-6: A resource should have narrative for robust management ( text.`div`.exists() ) | ||||
2. Device.id | |||||
Definition | The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. | ||||
Short | Logical id of this artifact | ||||
Comments | The only time that a resource does not have an id is when it is being submitted to the server using a create operation. | ||||
Control | 0..1 | ||||
Type | id | ||||
Is Modifier | false | ||||
Summary | true | ||||
4. Device.meta | |||||
Definition | The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource. | ||||
Short | Metadata about the resource | ||||
Control | 0..1 | ||||
Type | Meta | ||||
Is Modifier | false | ||||
Summary | true | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
6. Device.implicitRules | |||||
Definition | A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc. | ||||
Short | A set of rules under which this content was created | ||||
Comments | Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc. | ||||
Control | 0..1 | ||||
Type | uri | ||||
Is Modifier | true because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | true | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
8. Device.language | |||||
Definition | The base language in which the resource is written. | ||||
Short | Language of the resource content | ||||
Comments | Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). | ||||
Control | 0..1 | ||||
Binding | The codes SHOULD be taken from CommonLanguages A human language.
| ||||
Type | code | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
10. Device.text | |||||
Definition | A human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. | ||||
Short | Text summary of the resource, for human interpretation | ||||
Comments | Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later. | ||||
Control | 0..1 | ||||
Type | Narrative | ||||
Is Modifier | false | ||||
Summary | false | ||||
Alternate Names | narrative, html, xhtml, display | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
12. Device.contained | |||||
Definition | These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. | ||||
Short | Contained, inline Resources | ||||
Comments | This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels. | ||||
Control | 0..* | ||||
Type | Resource | ||||
Is Modifier | false | ||||
Summary | false | ||||
Alternate Names | inline resources, anonymous resources, contained resources | ||||
14. Device.extension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||||
Short | Additional content defined by implementations | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | false | ||||
Summary | false | ||||
Alternate Names | extensions, user content | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
16. Device.modifierExtension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||||
Short | Extensions that cannot be ignored | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them | ||||
Summary | false | ||||
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||||
Alternate Names | extensions, user content | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
18. Device.identifier | |||||
Definition | Unique instance identifiers assigned to a device by manufacturers other organizations or owners. | ||||
Short | Instance identifier | ||||
Comments | The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used. | ||||
Note | This is a business identifier, not a resource identifier (see discussion) | ||||
Control | 0..* | ||||
Type | Identifier | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
20. Device.definition | |||||
Definition | The reference to the definition for the device. | ||||
Short | The reference to the definition for the device | ||||
Control | 0..1 | ||||
Type | Reference(DeviceDefinition) | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
22. Device.udiCarrier | |||||
Definition | Unique device identifier (UDI) assigned to device label or package. Note that the Device may include multiple udiCarriers as it either may include just the udiCarrier for the jurisdiction it is sold, or for multiple jurisdictions it could have been sold. | ||||
Short | Unique Device Identifier (UDI) Barcode string | ||||
Comments | Some devices may not have UDI information (for example. historical data or patient reported data). | ||||
Control | 0..1 | ||||
Type | BackboneElement | ||||
Is Modifier | false | ||||
Must Support | true | ||||
Summary | true | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
24. Device.udiCarrier.id | |||||
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | ||||
Short | Unique id for inter-element referencing | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
XML Format | In the XML format, this property is represented as an attribute. | ||||
Summary | false | ||||
26. Device.udiCarrier.extension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||||
Short | Additional content defined by implementations | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | false | ||||
Summary | false | ||||
Alternate Names | extensions, user content | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
28. Device.udiCarrier.modifierExtension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||||
Short | Extensions that cannot be ignored even if unrecognized | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them | ||||
Summary | true | ||||
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||||
Alternate Names | extensions, user content, modifiers | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
30. Device.udiCarrier.deviceIdentifier | |||||
Definition | The device identifier (DI) is a mandatory, fixed portion of a UDI that identifies the labeler and the specific version or model of a device. | ||||
Short | Mandatory fixed portion of UDI | ||||
Control | 1..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Must Support | true | ||||
Summary | true | ||||
Alternate Names | DI | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
32. Device.udiCarrier.issuer | |||||
Definition | Organization that is charged with issuing UDIs for devices. For example, the US FDA issuers include :
| ||||
Short | UDI Issuing Organization | ||||
Control | 0..1 | ||||
Type | uri | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Alternate Names | Barcode System | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
34. Device.udiCarrier.jurisdiction | |||||
Definition | The identity of the authoritative source for UDI generation within a jurisdiction. All UDIs are globally unique within a single namespace with the appropriate repository uri as the system. For example, UDIs of devices managed in the U.S. by the FDA, the value is http://hl7.org/fhir/NamingSystem/fda-udi. | ||||
Short | Regional UDI authority | ||||
Control | 0..1 | ||||
Type | uri | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Requirements | Allows a recipient of a UDI to know which database will contain the UDI-associated metadata. | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
36. Device.udiCarrier.carrierAIDC | |||||
Definition | The full UDI carrier of the Automatic Identification and Data Capture (AIDC) technology representation of the barcode string as printed on the packaging of the device - e.g., a barcode or RFID. Because of limitations on character sets in XML and the need to round-trip JSON data through XML, AIDC Formats SHALL be base64 encoded. | ||||
Short | UDI Machine Readable Barcode String | ||||
Comments | The AIDC form of UDIs should be scanned or otherwise used for the identification of the device whenever possible to minimize errors in records resulting from manual transcriptions. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label. | ||||
Control | 0..1 | ||||
Type | base64Binary | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | true | ||||
Alternate Names | Automatic Identification and Data Capture | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
38. Device.udiCarrier.carrierHRF | |||||
Definition | The full UDI carrier as the human readable form (HRF) representation of the barcode string as printed on the packaging of the device. | ||||
Short | UDI Human Readable Barcode String | ||||
Comments | If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label. | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Must Support | true | ||||
Summary | true | ||||
Alternate Names | Human Readable Form, UDI, Barcode String | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
40. Device.udiCarrier.entryType | |||||
Definition | A coded entry to indicate how the data was entered. | ||||
Short | barcode | rfid | manual + | ||||
Control | 0..1 | ||||
Binding | The codes SHALL be taken from UDIEntryType Codes to identify how UDI data was entered. | ||||
Type | code | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Requirements | Supports a way to distinguish hand entered from machine read data. | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
42. Device.status | |||||
Definition | Status of the Device availability. | ||||
Short | active | inactive | entered-in-error | unknown | ||||
Comments | This element is labeled as a modifier because the status contains the codes inactive and entered-in-error that mark the device (record)as not currently valid. | ||||
Control | 0..1 | ||||
Binding | The codes SHALL be taken from FHIRDeviceStatus The availability status of the device. | ||||
Type | code | ||||
Is Modifier | true because This element is labelled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | true | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
44. Device.statusReason | |||||
Definition | Reason for the dtatus of the Device availability. | ||||
Short | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off | ||||
Control | 0..* | ||||
Binding | Unless not suitable, these codes SHALL be taken from FHIRDeviceStatusReason The availability status reason of the device. | ||||
Type | CodeableConcept | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
46. Device.distinctIdentifier | |||||
Definition | The distinct identification string as required by regulation for a human cell, tissue, or cellular and tissue-based product. | ||||
Short | The distinct identification string | ||||
Comments | For example, this applies to devices in the United States regulated under Code of Federal Regulation 21CFR§1271.290(c). | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Must Support | true | ||||
Summary | false | ||||
Alternate Names | Distinct Identification Code (DIC) | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
48. Device.manufacturer | |||||
Definition | A name of the manufacturer. | ||||
Short | Name of device manufacturer | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
50. Device.manufactureDate | |||||
Definition | The date and time when the device was manufactured. | ||||
Short | Date when the device was made | ||||
Control | 0..1 | ||||
Type | dateTime | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Must Support | true | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
52. Device.expirationDate | |||||
Definition | The date and time beyond which this device is no longer valid or should not be used (if applicable). | ||||
Short | Date and time of expiry of this device (if applicable) | ||||
Control | 0..1 | ||||
Type | dateTime | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Must Support | true | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
54. Device.lotNumber | |||||
Definition | Lot number assigned by the manufacturer. | ||||
Short | Lot number of manufacture | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Must Support | true | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
56. Device.serialNumber | |||||
Definition | The serial number assigned by the organization when the device was manufactured. | ||||
Short | Serial number assigned by the manufacturer | ||||
Comments | Alphanumeric Maximum 20. | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Must Support | true | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
58. Device.deviceName | |||||
Definition | This represents the manufacturer's name of the device as provided by the device, from a UDI label, or by a person describing the Device. This typically would be used when a person provides the name(s) or when the device represents one of the names available from DeviceDefinition. | ||||
Short | The name of the device as given by the manufacturer | ||||
Control | 0..* | ||||
Type | BackboneElement | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
60. Device.deviceName.id | |||||
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | ||||
Short | Unique id for inter-element referencing | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
XML Format | In the XML format, this property is represented as an attribute. | ||||
Summary | false | ||||
62. Device.deviceName.extension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||||
Short | Additional content defined by implementations | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | false | ||||
Summary | false | ||||
Alternate Names | extensions, user content | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
64. Device.deviceName.modifierExtension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||||
Short | Extensions that cannot be ignored even if unrecognized | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them | ||||
Summary | true | ||||
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||||
Alternate Names | extensions, user content, modifiers | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
66. Device.deviceName.name | |||||
Definition | The name of the device. | ||||
Short | The name of the device | ||||
Control | 1..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Alternate Names | Σ | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
68. Device.deviceName.type | |||||
Definition | The type of deviceName. UDILabelName | UserFriendlyName | PatientReportedName | ManufactureDeviceName | ModelName. | ||||
Short | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other | ||||
Control | 1..1 | ||||
Binding | The codes SHALL be taken from DeviceNameType The type of name the device is referred by. | ||||
Type | code | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
70. Device.modelNumber | |||||
Definition | The model number for the device. | ||||
Short | The model number for the device | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
72. Device.partNumber | |||||
Definition | The part number of the device. | ||||
Short | The part number of the device | ||||
Comments | Alphanumeric Maximum 20. | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
74. Device.type | |||||
Definition | The kind or type of device. | ||||
Short | The kind or type of device | ||||
Control | 1..1 | ||||
Binding | Unless not suitable, these codes SHALL be taken from FHIRDeviceTypes Codes to identify medical devices | ||||
Type | CodeableConcept | ||||
Is Modifier | false | ||||
Must Support | true | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
76. Device.specialization | |||||
Definition | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication. | ||||
Short | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | ||||
Control | 0..* | ||||
Type | BackboneElement | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
78. Device.specialization.id | |||||
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | ||||
Short | Unique id for inter-element referencing | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
XML Format | In the XML format, this property is represented as an attribute. | ||||
Summary | false | ||||
80. Device.specialization.extension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||||
Short | Additional content defined by implementations | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | false | ||||
Summary | false | ||||
Alternate Names | extensions, user content | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
82. Device.specialization.modifierExtension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||||
Short | Extensions that cannot be ignored even if unrecognized | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them | ||||
Summary | true | ||||
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||||
Alternate Names | extensions, user content, modifiers | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
84. Device.specialization.systemType | |||||
Definition | The standard that is used to operate and communicate. | ||||
Short | The standard that is used to operate and communicate | ||||
Control | 1..1 | ||||
Type | CodeableConcept | ||||
Is Modifier | false | ||||
Summary | false | ||||
Alternate Names | Σ | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
86. Device.specialization.version | |||||
Definition | The version of the standard that is used to operate and communicate. | ||||
Short | The version of the standard that is used to operate and communicate | ||||
Note | This is a business versionId, not a resource version id (see discussion) | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
88. Device.version | |||||
Definition | The actual design of the device or software version running on the device. | ||||
Short | The actual design of the device or software version running on the device | ||||
Note | This is a business versionId, not a resource version id (see discussion) | ||||
Control | 0..* | ||||
Type | BackboneElement | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
90. Device.version.id | |||||
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | ||||
Short | Unique id for inter-element referencing | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
XML Format | In the XML format, this property is represented as an attribute. | ||||
Summary | false | ||||
92. Device.version.extension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||||
Short | Additional content defined by implementations | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | false | ||||
Summary | false | ||||
Alternate Names | extensions, user content | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
94. Device.version.modifierExtension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||||
Short | Extensions that cannot be ignored even if unrecognized | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them | ||||
Summary | true | ||||
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||||
Alternate Names | extensions, user content, modifiers | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
96. Device.version.type | |||||
Definition | The type of the device version. | ||||
Short | The type of the device version | ||||
Control | 0..1 | ||||
Type | CodeableConcept | ||||
Is Modifier | false | ||||
Summary | false | ||||
Alternate Names | Σ | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
98. Device.version.component | |||||
Definition | A single component of the device version. | ||||
Short | A single component of the device version | ||||
Control | 0..1 | ||||
Type | Identifier | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
100. Device.version.value | |||||
Definition | The version text. | ||||
Short | The version text | ||||
Control | 1..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
102. Device.property | |||||
Definition | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties. | ||||
Short | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | ||||
Control | 0..* | ||||
Type | BackboneElement | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
104. Device.property.id | |||||
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | ||||
Short | Unique id for inter-element referencing | ||||
Control | 0..1 | ||||
Type | string | ||||
Is Modifier | false | ||||
XML Format | In the XML format, this property is represented as an attribute. | ||||
Summary | false | ||||
106. Device.property.extension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||||
Short | Additional content defined by implementations | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | false | ||||
Summary | false | ||||
Alternate Names | extensions, user content | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
108. Device.property.modifierExtension | |||||
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||||
Short | Extensions that cannot be ignored even if unrecognized | ||||
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||||
Control | 0..* | ||||
Type | Extension | ||||
Is Modifier | true because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them | ||||
Summary | true | ||||
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||||
Alternate Names | extensions, user content, modifiers | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) )ext-1: Must have either extensions or value[x], not both ( extension.exists() != value.exists() ) | ||||
110. Device.property.type | |||||
Definition | Code that specifies the property DeviceDefinitionPropetyCode (Extensible). | ||||
Short | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | ||||
Control | 1..1 | ||||
Type | CodeableConcept | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
112. Device.property.valueQuantity | |||||
Definition | Property value as a quantity. | ||||
Short | Property value as a quantity | ||||
Control | 0..* | ||||
Type | Quantity | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
114. Device.property.valueCode | |||||
Definition | Property value as a code, e.g., NTP4 (synced to NTP). | ||||
Short | Property value as a code, e.g., NTP4 (synced to NTP) | ||||
Control | 0..* | ||||
Type | CodeableConcept | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
116. Device.patient | |||||
Definition | Patient information, If the device is affixed to a person. | ||||
Short | Patient to whom Device is affixed | ||||
Control | 1..1 | ||||
Type | Reference(US Core Patient Profile) | ||||
Is Modifier | false | ||||
Must Support | true | ||||
Summary | false | ||||
Requirements | If the device is implanted in a patient, then need to associate the device to the patient. | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
118. Device.owner | |||||
Definition | An organization that is responsible for the provision and ongoing maintenance of the device. | ||||
Short | Organization responsible for device | ||||
Control | 0..1 | ||||
Type | Reference(Organization) | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
120. Device.contact | |||||
Definition | Contact details for an organization or a particular human that is responsible for the device. | ||||
Short | Details for human/organization for support | ||||
Comments | used for troubleshooting etc. | ||||
Control | 0..* | ||||
Type | ContactPoint | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
122. Device.location | |||||
Definition | The place where the device can be found. | ||||
Short | Where the device is found | ||||
Control | 0..1 | ||||
Type | Reference(Location) | ||||
Is Modifier | false | ||||
Summary | false | ||||
Requirements | Device.location can be used to track device location. | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
124. Device.url | |||||
Definition | A network address on which the device may be contacted directly. | ||||
Short | Network address to contact device | ||||
Comments | If the device is running a FHIR server, the network address should be the Base URL from which a conformance statement may be retrieved. | ||||
Control | 0..1 | ||||
Type | uri | ||||
Is Modifier | false | ||||
Primitive Value | This primitive element may be present, or absent, or replaced by an extension | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
126. Device.note | |||||
Definition | Descriptive information, usage information or implantation information that is not captured in an existing element. | ||||
Short | Device notes and comments | ||||
Control | 0..* | ||||
Type | Annotation | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
128. Device.safety | |||||
Definition | Provides additional safety characteristics about a medical device. For example devices containing latex. | ||||
Short | Safety Characteristics of Device | ||||
Control | 0..* | ||||
Type | CodeableConcept | ||||
Is Modifier | false | ||||
Summary | true | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) | ||||
130. Device.parent | |||||
Definition | The parent device. | ||||
Short | The parent device | ||||
Control | 0..1 | ||||
Type | Reference(Device) | ||||
Is Modifier | false | ||||
Summary | false | ||||
Invariants | ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()) ) |