This page is part of the US Core (v7.0.0-ballot: STU7 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 6.1.0. For a full list of available versions, see the Directory of published versions
Page standards status: Informative |
{
"resourceType" : "Observation",
"id" : "satO2-fiO2",
"meta" : {
"profile" : [
🔗 "http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry|7.0.0-ballot"
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Observation</b><a name=\"satO2-fiO2\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Observation "satO2-fiO2" </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-us-core-pulse-oximetry.html\">US Core Pulse Oximetry Profile (version 7.0.0-ballot)</a></p></div><p><b>identifier</b>: id:\u00a0o1223435-10</p><p><b>status</b>: final</p><p><b>category</b>: Vital Signs <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.3.0/CodeSystem-observation-category.html\">Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: Oxygen saturation in Arterial blood <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#2708-6; <a href=\"https://loinc.org/\">LOINC</a>#59408-5 "Oxygen saturation in Arterial blood by Pulse oximetry"; <a href=\"http://terminology.hl7.org/5.3.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#150456 "MDC_PULS_OXIM_SAT_O2")</span></p><p><b>subject</b>: <a href=\"Patient-example.html\">Patient/example</a> " SHAW"</p><p><b>effective</b>: 2014-12-05 09:30:10+0100</p><p><b>value</b>: 95 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code % = '%')</span></p><p><b>interpretation</b>: Normal <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.3.0/CodeSystem-v3-ObservationInterpretation.html\">ObservationInterpretation</a>#N)</span></p><p><b>device</b>: <span>: Acme Pulse Oximeter 2000</span></p><h3>ReferenceRanges</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td style=\"display: none\">*</td><td>90 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code % = '%')</span></td><td>99 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code % = '%')</span></td></tr></table><h3>Components</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Code</b></td><td><b>Value[x]</b></td></tr><tr><td style=\"display: none\">*</td><td>Inhaled oxygen flow rate <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#3151-8)</span></td><td>6 liters/min<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code L/min = 'L/min')</span></td></tr></table></div>"
},
"identifier" : [
{
"system" : "http://goodcare.org/observation/id",
"value" : "o1223435-10"
}
],
"status" : "final",
"category" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/observation-category",
"code" : "vital-signs",
"display" : "Vital Signs"
}
],
"text" : "Vital Signs"
}
],
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "2708-6",
"display" : "Oxygen saturation in Arterial blood"
},
{
"system" : "http://loinc.org",
"code" : "59408-5",
"display" : "Oxygen saturation in Arterial blood by Pulse oximetry"
},
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "150456",
"display" : "MDC_PULS_OXIM_SAT_O2"
}
]
},
"subject" : {
🔗 "reference" : "Patient/example"
},
"effectiveDateTime" : "2014-12-05T09:30:10+01:00",
"valueQuantity" : {
"value" : 95,
"unit" : "%",
"system" : "http://unitsofmeasure.org",
"code" : "%"
},
"interpretation" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
"code" : "N",
"display" : "Normal"
}
],
"text" : "Normal"
}
],
"device" : {
"display" : "Acme Pulse Oximeter 2000"
},
"referenceRange" : [
{
"low" : {
"value" : 90,
"unit" : "%",
"system" : "http://unitsofmeasure.org",
"code" : "%"
},
"high" : {
"value" : 99,
"unit" : "%",
"system" : "http://unitsofmeasure.org",
"code" : "%"
}
}
],
"component" : [
{
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "3151-8",
"display" : "Inhaled oxygen flow rate"
}
],
"text" : "Inhaled oxygen flow rate"
},
"valueQuantity" : {
"value" : 6,
"unit" : "liters/min",
"system" : "http://unitsofmeasure.org",
"code" : "L/min"
}
}
]
}
IG © 2023+ HL7 International / Cross-Group Projects. Package hl7.fhir.us.core#7.0.0-ballot based on FHIR 4.0.1. Generated 2023-12-19
Links: Table of Contents |
QA Report
| Version History |
|
Propose a change