CodeX Radiation Therapy
2.0.0-ballot - Ballot United States of America flag

This page is part of the CodeX™ Radiation Therapy (v2.0.0-ballot: STU 2 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions

Extension: Energy or Isotope

Official URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope Version: 2.0.0-ballot
Active as of 2024-04-09 Computable Name: RadiotherapyEnergyOrIsotope
Other Identifiers: OID:2.16.840.1.113883.4.642.40.14.42.14

The radiation energy used for radiotherapy. The energy spectrum is characterized by the maximum energy, the maximum accelaration voltage, or the used isotope.

Context of Use

This extension may be used on the following element(s):

  • Element ID Procedure
  • Element ID ServiceRequest
  • Element ID ActivityDefinition
  • Element ID Device
  • Extension URL http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique

Usage info

Usage:

Formal Views of Extension Content

Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.

This structure is derived from Extension

Summary

Simple Extension of type CodeableConcept, Quantity: The radiation energy used for radiotherapy. The energy spectrum is characterized by the maximum energy, the maximum accelaration voltage, or the used isotope.

This structure is derived from Extension

NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension 0..* Extension Radiotherapy Energy or Isotope
... extension 0..0
... url 1..1 uri "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope"
... Slices for value[x] 1..1 Value of extension
Slice: Unordered, Open by type:$this
.... valueCodeableConcept CodeableConcept
.... valueQuantity Quantity(SimpleQuantity)
.... value[x]:valueQuantity 0..1 SimpleQuantity The spectrum of radiation energy characterized by a maximum value. For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy.
Binding: Radiotherapy Energy Unit Value Set (required)
..... value 1..1 decimal Numerical value (with implicit precision)
..... system 1..1 uri System that defines coded unit form
..... code 1..1 code Coded form of the unit
.... value[x]:valueCodeableConcept 0..1 CodeableConcept The isotope used for radiotherapy.
Binding: Radiotherapy Isotope Value Set (extensible)

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension 0..* Extension Radiotherapy Energy or Isotope
... id 0..1 string Unique id for inter-element referencing
... extension 0..0
... url 1..1 uri "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope"
.... valueCodeableConcept CodeableConcept
.... valueQuantity Quantity(SimpleQuantity)
.... value[x]:valueQuantity C 0..1 SimpleQuantity The spectrum of radiation energy characterized by a maximum value. For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy.
Binding: Radiotherapy Energy Unit Value Set (required)
qty-3: If a code for the unit is present, the system SHALL also be present
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
..... value Σ 1..1 decimal Numerical value (with implicit precision)
..... unit Σ 0..1 string Unit representation
..... system ΣC 1..1 uri System that defines coded unit form
..... code Σ 1..1 code Coded form of the unit
.... value[x]:valueCodeableConcept 0..1 CodeableConcept The isotope used for radiotherapy.
Binding: Radiotherapy Isotope Value Set (extensible)

doco Documentation for this format

This structure is derived from Extension

Summary

Simple Extension of type CodeableConcept, Quantity: The radiation energy used for radiotherapy. The energy spectrum is characterized by the maximum energy, the maximum accelaration voltage, or the used isotope.

Differential View

This structure is derived from Extension

NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension 0..* Extension Radiotherapy Energy or Isotope
... extension 0..0
... url 1..1 uri "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope"
... Slices for value[x] 1..1 Value of extension
Slice: Unordered, Open by type:$this
.... valueCodeableConcept CodeableConcept
.... valueQuantity Quantity(SimpleQuantity)
.... value[x]:valueQuantity 0..1 SimpleQuantity The spectrum of radiation energy characterized by a maximum value. For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy.
Binding: Radiotherapy Energy Unit Value Set (required)
..... value 1..1 decimal Numerical value (with implicit precision)
..... system 1..1 uri System that defines coded unit form
..... code 1..1 code Coded form of the unit
.... value[x]:valueCodeableConcept 0..1 CodeableConcept The isotope used for radiotherapy.
Binding: Radiotherapy Isotope Value Set (extensible)

doco Documentation for this format

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension 0..* Extension Radiotherapy Energy or Isotope
... id 0..1 string Unique id for inter-element referencing
... extension 0..0
... url 1..1 uri "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope"
.... valueCodeableConcept CodeableConcept
.... valueQuantity Quantity(SimpleQuantity)
.... value[x]:valueQuantity C 0..1 SimpleQuantity The spectrum of radiation energy characterized by a maximum value. For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy.
Binding: Radiotherapy Energy Unit Value Set (required)
qty-3: If a code for the unit is present, the system SHALL also be present
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
..... value Σ 1..1 decimal Numerical value (with implicit precision)
..... unit Σ 0..1 string Unit representation
..... system ΣC 1..1 uri System that defines coded unit form
..... code Σ 1..1 code Coded form of the unit
.... value[x]:valueCodeableConcept 0..1 CodeableConcept The isotope used for radiotherapy.
Binding: Radiotherapy Isotope Value Set (extensible)

doco Documentation for this format

 

Other representations of profile: CSV, Excel, Schematron

Terminology Bindings

PathConformanceValueSetURI
Extension.value[x]:valueQuantityrequiredRadiotherapyEnergyUnitVS
http://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-radiotherapy-energy-unit-vs
from this IG
Extension.value[x]:valueCodeableConceptextensibleRadiotherapyIsotopeVS
http://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-radiotherapy-isotope-vs