This page is part of the CodeX™ Radiation Therapy (v2.0.0-ballot: STU 2 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-intrafraction-verification | Version: 2.0.0-ballot | |||
Active as of 2024-04-09 | Computable Name: IntrafractionVerification | |||
Other Identifiers: OID:2.16.840.1.113883.4.642.40.14.42.3 |
Verification of the patient or target position during a treatment fraction.
Context of Use
This extension may be used on the following element(s):
This extension is used to capture the type of intrafraction verificiation used during treatment.
Intrafraction Verification Method | Procedure Code | Qualifier Code |
---|---|---|
X-ray - one source | SCT#168537006 Plain radiography (procedure) | SCT#50607009 “Singular (qualifier value) or absent |
X-ray - multiple sources | SCT#168537006 Plain radiography (procedure) | SCT#255204007 “Multiple (qualifier value) |
Ultrasound | SCT#16310003 Ultrasonography (procedure) | None |
CT | SCT#77477000 Computed tomography (procedure) | None |
MRI | SCT#113091000 Magnetic resonance imaging (procedure) | None |
Fiducial Markers | SnomedRequestedCS#USCRS-35604 Imaging guidance using fiducial markers (procedure) | None |
Electromagnetic Transponder | SnomedRequestedCS#USCRS-35606 Radiotherapy using electromagnetic transponder guidance (procedure) | None |
Surface Guided | SnomedRequestedCS#1297350006 “Surface guided radiation therapy (procedure)” | None |
One of the above types SHOULD be used. Use of other metrics will generate a warning.
Usage info
Usage:
Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.
This structure is derived from Extension
This structure is derived from Extension
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | C | 0..* | Extension | Intrafraction Verification IntrafractionVerificationQualifierAllowed: Qualifier is only allowed for X-Ray procedure. |
extension | 1..* | Extension | Extension | |
extension:procedure | 1..1 | Extension | Extension | |
extension | 0..0 | |||
url | 1..1 | uri | "procedure" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Intrafraction Verification Procedure Value Set (extensible) | |
extension:qualifier | 0..1 | Extension | Extension | |
extension | 0..0 | |||
url | 1..1 | uri | "qualifier" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Intrafraction Verification Procedure Qualifier Value Set (extensible) | |
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-intrafraction-verification" | |
value[x] | 0..0 | |||
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | C | 0..* | Extension | Intrafraction Verification IntrafractionVerificationQualifierAllowed: Qualifier is only allowed for X-Ray procedure. |
id | 0..1 | string | Unique id for inter-element referencing | |
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |
extension:procedure | 1..1 | Extension | Extension | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "procedure" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Intrafraction Verification Procedure Value Set (extensible) | |
extension:qualifier | 0..1 | Extension | Extension | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "qualifier" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Intrafraction Verification Procedure Qualifier Value Set (extensible) | |
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-intrafraction-verification" | |
Documentation for this format |
This structure is derived from Extension
Differential View
This structure is derived from Extension
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | C | 0..* | Extension | Intrafraction Verification IntrafractionVerificationQualifierAllowed: Qualifier is only allowed for X-Ray procedure. |
extension | 1..* | Extension | Extension | |
extension:procedure | 1..1 | Extension | Extension | |
extension | 0..0 | |||
url | 1..1 | uri | "procedure" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Intrafraction Verification Procedure Value Set (extensible) | |
extension:qualifier | 0..1 | Extension | Extension | |
extension | 0..0 | |||
url | 1..1 | uri | "qualifier" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Intrafraction Verification Procedure Qualifier Value Set (extensible) | |
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-intrafraction-verification" | |
value[x] | 0..0 | |||
Documentation for this format |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | C | 0..* | Extension | Intrafraction Verification IntrafractionVerificationQualifierAllowed: Qualifier is only allowed for X-Ray procedure. |
id | 0..1 | string | Unique id for inter-element referencing | |
Slices for extension | 1..* | Extension | Extension Slice: Unordered, Open by value:url | |
extension:procedure | 1..1 | Extension | Extension | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "procedure" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Intrafraction Verification Procedure Value Set (extensible) | |
extension:qualifier | 0..1 | Extension | Extension | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "qualifier" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Intrafraction Verification Procedure Qualifier Value Set (extensible) | |
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-intrafraction-verification" | |
Documentation for this format |
Other representations of profile: CSV, Excel, Schematron
Path | Conformance | ValueSet | URI |
Extension.extension:procedure.value[x] | extensible | IntrafractionVerificationProcedureVShttp://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-intrafraction-verification-procedure-vs from this IG | |
Extension.extension:qualifier.value[x] | extensible | IntrafractionVerificationQualifierVShttp://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-intrafraction-verification-qualifier-vs from this IG |
Id | Grade | Path(s) | Details | Requirements |
IntrafractionVerificationQualifierAllowed | error | Extension | Qualifier is only allowed for X-Ray procedure. : extension.where(url = 'qualifier').exists() implies (extension.where(url = 'procedure').exists() and extension.where(url = 'procedure').value.exists() and extension.where(url = 'procedure').value.coding.all( (system = 'http://snomed.info/sct') and (code = '168537006') ) ) |