<?xml version="1.0" encoding="UTF-8"?>
<Device xmlns="http://hl7.org/fhir">
<id value="example-udi1"/>
<text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="example-udi1"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device "example-udi1" </p> </div> <p> <b> identifier</b> : 1234-5678-90AB-CDEF, Serial Number: 10987654d321</p> <h3> UdiCarriers</h3> <table class="grid"><tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> CarrierAIDC</b> </td> <td> <b> CarrierHRF</b> </td> <td> <b> EntryType</b> </td> </tr> <tr> <td> *</td> <td> 00844588003288</td> <td> <a href="http://hl7.org/fhir/NamingSystem/gs1">http://hl7.org/fhir/NamingSystem/gs1</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH</td> <td> {01}00844588003288{17}141120{10}7654321D{21}10987654d321</td> <td> barcode</td> </tr> </table> <p> <b> status</b> : active</p> <p> <b> manufacturer</b> : Acme Devices, Inc</p> <p> <b> expirationDate</b> : 2014-11-20</p> <p> <b> lotNumber</b> : 7654321D</p> <h3> Names</h3> <table class="grid"><tr> <td> -</td> <td> <b> Value</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> PM/Octane 2014</td> <td> user-friendly-name</td> </tr> </table> <p> <b> type</b> : Coated femoral stem prosthesis, modular <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #468063009)</span> </p> <p> <b> safety</b> : <span title=" <association>
<status>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/device-association-status&q
uot; />
<code value="attached"/>
</coding>
</status>
<humanSubject>
<reference value="Patient/example"/>
</humanSubject>
</association> ">MR Unsafe <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (unknown#mr-unsafe)</span> </span> </p> </div> </text> <identifier>
<type>
<coding>
<system value="http://acme.com/devices/pacemakers/octane/serial"/>
</coding>
</type>
<value value="1234-5678-90AB-CDEF"/>
</identifier>
<identifier>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0203"/>
<code value="SNO"/>
</coding>
</type>
<value value="10987654d321"/>
</identifier>
<udiCarrier>
<deviceIdentifier value="00844588003288"/>
<issuer value="http://hl7.org/fhir/NamingSystem/gs1"/>
<jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/>
<carrierAIDC value="XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH"/>
<carrierHRF value="{01}00844588003288{17}141120{10}7654321D{21}10987654d321"/>
<entryType value="barcode"/>
</udiCarrier>
<status value="active"/>
<manufacturer value="Acme Devices, Inc"/>
<expirationDate value="2014-11-20"/>
<lotNumber value="7654321D"/>
<name>
<value value="PM/Octane 2014"/>
<type value="user-friendly-name"/>
</name>
<type>
<coding>
<system value="http://snomed.info/sct"/>
<code value="468063009"/>
<display value="Coated femoral stem prosthesis, modular"/>
</coding>
<text value="Coated femoral stem prosthesis, modular"/>
</type>
<safety>
<coding>
<system value="urn:oid:2.16.840.1.113883.3.26.1.1"/>
<code value="mr-unsafe"/>
<display value="MR Unsafe"/>
</coding>
<text value="MR Unsafe"/>
</safety>
</Device>
Usage note: every effort has been made to ensure that the
examples are correct and useful, but they are not a normative part
of the specification.