Release 5

This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3

Example Device/example-udi1 (JSON)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

Raw JSON (canonical form + also see JSON Format Specification)

example-udi1

{
  "resourceType" : "Device",
  "id" : "example-udi1",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"example-udi1\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device &quot;example-udi1&quot; </p></div><p><b>identifier</b>: 1234-5678-90AB-CDEF, Serial Number: 10987654d321</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierAIDC</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>00844588003288</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1\">http://hl7.org/fhir/NamingSystem/gs1</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH</td><td>{01}00844588003288{17}141120{10}7654321D{21}10987654d321</td><td>barcode</td></tr></table><p><b>status</b>: active</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>expirationDate</b>: 2014-11-20</p><p><b>lotNumber</b>: 7654321D</p><h3>Names</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>PM/Octane 2014</td><td>user-friendly-name</td></tr></table><p><b>type</b>: Coated femoral stem prosthesis, modular <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#468063009)</span></p><p><b>safety</b>: <span title=\"  &lt;association&gt;\n\t  &lt;status&gt; \n\t     &lt;coding&gt;\n\t\t   &lt;system value=&quot;http://terminology.hl7.org/CodeSystem/device-association-status&quot; /&gt;\n           &lt;code value=&quot;attached&quot;/&gt;\n\t\t &lt;/coding&gt;\n\t  &lt;/status&gt;\n      &lt;humanSubject&gt;\n\t\t&lt;reference value=&quot;Patient/example&quot;/&gt;\n\t  &lt;/humanSubject&gt;\n\t&lt;/association&gt;  \">MR Unsafe <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (unknown#mr-unsafe)</span></span></p></div>"
  },
  "identifier" : [{
    "type" : {
      "coding" : [{
        "system" : "http://acme.com/devices/pacemakers/octane/serial"
      }]
    },
    "value" : "1234-5678-90AB-CDEF"
  },
  {
    "type" : {
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/v2-0203",
        "code" : "SNO"
      }]
    },
    "value" : "10987654d321"
  }],
  "udiCarrier" : [{
    "deviceIdentifier" : "00844588003288",
    "issuer" : "http://hl7.org/fhir/NamingSystem/gs1",
    "jurisdiction" : "http://hl7.org/fhir/NamingSystem/fda-udi",
    "carrierAIDC" : "XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH",
    "carrierHRF" : "{01}00844588003288{17}141120{10}7654321D{21}10987654d321",
    "entryType" : "barcode"
  }],
  "status" : "active",
  "manufacturer" : "Acme Devices, Inc",
  "expirationDate" : "2014-11-20",
  "lotNumber" : "7654321D",
  "name" : [{
    "value" : "PM/Octane 2014",
    "type" : "user-friendly-name"
  }],
  "type" : [{
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "468063009",
      "display" : "Coated femoral stem prosthesis, modular"
    }],
    "text" : "Coated femoral stem prosthesis, modular"
  }],
  "safety" : [{
    "coding" : [{
      "system" : "urn:oid:2.16.840.1.113883.3.26.1.1",
      "code" : "mr-unsafe",
      "display" : "MR Unsafe"
    }],
    "text" : "MR Unsafe"
  }]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.