This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3
Orders and Observations Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device |
Implantable device/UDI example GS-1 Format (id = "example-udi1")
<Device xmlns="http://hl7.org/fhir"> <id value="example-udi1"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : example-udi1</p> <p> <b> identifier</b> : 1234-5678-90AB-CDEF, Serial Number = 10987654d321</p> <h3> Udis</h3> <table> <tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Name</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> CarrierHRF</b> </td> <td> <b> CarrierAIDC</b> </td> <td> <b> Issuer</b> </td> <td> <b> EntryType</b> </td> </tr> <tr> <td> *</td> <td> 00844588003288</td> <td> FHIR® Hip System</td> <td> <a> http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> {01}00844588003288{17}141120{10}7654321D{21}10987654d321</td> <td> XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH</td> <td> <a> http://hl7.org/fhir/NamingSystem/gs1</a> </td> <td> barcode</td> </tr> </table> <p> <b> status</b> : active</p> <p> <b> type</b> : Coated femoral stem prosthesis, modular <span> (Details : {SNOMED CT code '468063009' = 'Coated femoral stem prosthesis, modular', given as 'Coated femoral stem prosthesis, modular'})</span> </p> <p> <b> lotNumber</b> : 7654321D</p> <p> <b> manufacturer</b> : Acme Devices, Inc</p> <p> <b> expirationDate</b> : 20/11/2014</p> <p> <b> model</b> : PM/Octane 2014</p> <p> <b> patient</b> : <a> Patient/example</a> </p> <p> <b> safety</b> : MR Unsafe <span> (Details : {urn:oid:2.16.840.1.113883.3.26.1.1 code 'mr-unsafe' = 'mr-unsafe', given as 'MR Unsafe'})</span> </p> </div> </text> <identifier> <system value="http://acme.com/devices/pacemakers/octane/serial"/> <value value="1234-5678-90AB-CDEF"/> </identifier> <identifier> <type> <coding> <system value="http://hl7.org/fhir/identifier-type"/> <code value="SNO"/> </coding> </type> <value value="10987654d321"/> </identifier> <udi> <!-- The Device Identifier (DI) here so you can look up - in this case using the GUDID database --> <deviceIdentifier value="00844588003288"/> <!-- Brand name as listed in the GUDID database and supposedly on the label for this device --> <name value="FHIR® Hip System"/> <!-- This is US FDA example --> <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> <!-- The Human readable form here which is FDA GS-1 format of the udi --> <carrierHRF value="{01}00844588003288{17}141120{10}7654321D{21}10987654d321"/> <!-- based on the AIDC which has group separator control codes that can't be reproduced in xml so we use the base64 version. --> <carrierAIDC value="XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH"/> <!-- Orgnanizations accredited by the FDA to operate a system to issue UDIS for device currently the FDA has accredited three issuing agencies. GS1, HIBCC, and ICCBBA --> <issuer value="http://hl7.org/fhir/NamingSystem/gs1"/> <!-- YOu may want to know how the data was entered for data integrity reasons. This has overlap with Provenance which could identify the enterer --> <entryType value="barcode"/> </udi> <status value="active"/> <type> <coding> <system value="http://snomed.info/sct"/> <code value="468063009"/> <display value="Coated femoral stem prosthesis, modular"/> </coding> <text value="Coated femoral stem prosthesis, modular"/> <!-- note: optional text value added here for a prettier generated narrative --> </type> <lotNumber value="7654321D"/> <manufacturer value="Acme Devices, Inc"/> <expirationDate value="2014-11-20"/> <model value="PM/Octane 2014"/> <patient> <reference value="Patient/example"/> </patient> <safety> <coding> <system value="urn:oid:2.16.840.1.113883.3.26.1.1"/> <code value="mr-unsafe"/> <display value="MR Unsafe"/> </coding> <text value="MR Unsafe"/> <!-- note: optional text value added here for a prettier generated narrative --> </safety> </Device>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.