FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

4.3.1.230 Value Set http://hl7.org/fhir/ValueSet/diagnostic-report-status

Orders and Observations Work Group Maturity Level: 3InformativeUse Context: Any

This is a value set defined by the FHIR project.

Summary

Defining URL:http://hl7.org/fhir/ValueSet/diagnostic-report-status
Name:DiagnosticReportStatus
Definition:The status of the diagnostic report as a whole.
Committee:Orders and Observations Work Group
OID:2.16.840.1.113883.4.642.3.230 (for OID based terminology systems)
Source ResourceXML / JSON

This value set is used in the following places:


This value set includes codes from the following code systems:

 

This expansion generated 19 Apr 2017


This value set contains 10 concepts

Expansion based on http://hl7.org/fhir/diagnostic-report-status version 3.0.2

All codes from system http://hl7.org/fhir/diagnostic-report-status

CodeDisplayDefinition
registeredRegisteredThe existence of the report is registered, but there is nothing yet available.
partialPartialThis is a partial (e.g. initial, interim or preliminary) report: data in the report may be incomplete or unverified.
  preliminaryPreliminaryVerified early results are available, but not all results are final.
finalFinalThe report is complete and verified by an authorized person.
amendedAmendedSubsequent to being final, the report has been modified. This includes any change in the results, diagnosis, narrative text, or other content of a report that has been issued.
  correctedCorrectedSubsequent to being final, the report has been modified to correct an error in the report or referenced results.
  appendedAppendedSubsequent to being final, the report has been modified by adding new content. The existing content is unchanged.
cancelledCancelledThe report is unavailable because the measurement was not started or not completed (also sometimes called "aborted").
entered-in-errorEntered in ErrorThe report has been withdrawn following a previous final release. This electronic record should never have existed, though it is possible that real-world decisions were based on it. (If real-world activity has occurred, the status should be "cancelled" rather than "entered-in-error".)
unknownUnknownThe authoring system does not know which of the status values currently applies for this request. Note: This concept is not to be used for "other" - one of the listed statuses is presumed to apply, it's just not known which one.

 

See the full registry of value sets defined as part of FHIR.


Explanation of the columns that may appear on this page:

LevelA few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
SourceThe source of the definition of the code (when the value set draws in codes defined elsewhere)
CodeThe code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
DisplayThe display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
DefinitionAn explanation of the meaning of the concept