This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version in it's permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Imaging Integration Work Group | Maturity Level: 1 | Trial Use | Security Category: Patient | Compartments: Patient |
Detailed Descriptions for the elements in the ImagingSelection resource.
ImagingSelection | |
Element Id | ImagingSelection |
Definition | A selection of DICOM SOP instances and/or frames within a single Study and Series. This might include additional specifics such as an image region, an Observation UID or a Segmentation Number, allowing linkage to an Observation Resource or transferring this information along with the ImagingStudy Resource. |
Short Display | A selection of DICOM SOP instances and/or frames |
Cardinality | 0..* |
Type | DomainResource |
Summary | false |
ImagingSelection.identifier | |
Element Id | ImagingSelection.identifier |
Definition | A unique identifier assigned to this imaging selection. |
Short Display | Business Identifier for Imaging Selection |
Note | This is a business identifier, not a resource identifier (see discussion) |
Cardinality | 0..* |
Type | Identifier |
Requirements | Allows imaging selections to be distinguished and referenced. |
Summary | true |
Comments | This is a business identifier, not a resource identifier -- see discussion under Business Identifiers. |
ImagingSelection.status | |
Element Id | ImagingSelection.status |
Definition | The current state of the ImagingSelection resource. This is not the status of any ImagingStudy, ServiceRequest, or Task resources associated with the ImagingSelection. |
Short Display | available | entered-in-error | unknown |
Cardinality | 1..1 |
Terminology Binding | Imaging Selection Status (Required) |
Type | code |
Is Modifier | true (Reason: This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid) |
Summary | true |
Comments | Unknown does not represent "other" - one of the defined statuses must apply. Unknown is used when the authoring system is not sure what the current status is. |
ImagingSelection.subject | |
Element Id | ImagingSelection.subject |
Definition | The patient, or group of patients, location, device, organization, procedure or practitioner this imaging selection is about and into whose or what record the imaging selection is placed. |
Short Display | Subject of the selected instances |
Cardinality | 0..1 |
Type | Reference(Patient | Group | Device | Location | Organization | Procedure | Practitioner | Medication | Substance | Specimen) |
Summary | true |
ImagingSelection.issued | |
Element Id | ImagingSelection.issued |
Definition | The date and time this imaging selection was created. |
Short Display | Date / Time when this imaging selection was created |
Cardinality | 0..1 |
Type | instant |
Summary | true |
ImagingSelection.performer | |
Element Id | ImagingSelection.performer |
Definition | Selector of the instances – human or machine. |
Short Display | Selector of the instances (human or machine) |
Cardinality | 0..* |
Summary | true |
ImagingSelection.performer.function | |
Element Id | ImagingSelection.performer.function |
Definition | Distinguishes the type of involvement of the performer. |
Short Display | Type of performer |
Cardinality | 0..1 |
Terminology Binding | ImagingStudy series performer function (Extensible) |
Type | CodeableConcept |
Requirements | Allows disambiguation of the types and involvement of different performers. |
Summary | true |
ImagingSelection.performer.actor | |
Element Id | ImagingSelection.performer.actor |
Definition | Author – human or machine. |
Short Display | Author (human or machine) |
Cardinality | 0..1 |
Type | Reference(Practitioner | PractitionerRole | Device | Organization | CareTeam | Patient | RelatedPerson | HealthcareService) |
Summary | true |
ImagingSelection.basedOn | |
Element Id | ImagingSelection.basedOn |
Definition | A list of the diagnostic requests that resulted in this imaging selection being performed. |
Short Display | Associated request |
Cardinality | 0..* |
Type | Reference(CarePlan | ServiceRequest | Appointment | AppointmentResponse | Task) |
Alternate Names | AccessionNumber |
Summary | true |
ImagingSelection.category | |
Element Id | ImagingSelection.category |
Definition | Classifies the imaging selection. |
Short Display | Classifies the imaging selection |
Cardinality | 0..* |
Terminology Binding | KeyObjectSelectionDocumentTitle (Example) |
Type | CodeableConcept |
Requirements | Used for filtering what imaging selections are retrieved and displayed. |
Summary | true |
ImagingSelection.code | |
Element Id | ImagingSelection.code |
Definition | Reason for referencing the selected content. |
Short Display | Imaging Selection purpose text or code |
Cardinality | 1..1 |
Terminology Binding | KeyObjectSelectionDocumentTitle (Example) |
Type | CodeableConcept |
Requirements | Knowing what kind of observation is being made is essential to understanding the observation. |
Alternate Names | Description |
Summary | true |
Comments | All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation. |
ImagingSelection.studyUid | |
Element Id | ImagingSelection.studyUid |
Definition | The Study Instance UID for the DICOM Study from which the images were selected. |
Short Display | DICOM Study Instance UID |
Cardinality | 0..1 |
Type | id |
Requirements | DICOM Study Instance UID. Required unless frameOfReferenceUid and imageRegion are present and instance is not present. |
Alternate Names | StudyInstanceUID |
Summary | true |
Comments | See DICOM PS3.3 C.7.2 . |
ImagingSelection.derivedFrom | |
Element Id | ImagingSelection.derivedFrom |
Definition | The imaging study from which the imaging selection is made. |
Short Display | The imaging study from which the imaging selection is derived |
Cardinality | 0..* |
Type | Reference(ImagingStudy | DocumentReference) |
Summary | true |
ImagingSelection.endpoint | |
Element Id | ImagingSelection.endpoint |
Definition | The network service providing retrieval access to the selected images, frames, etc. See implementation notes for information about using DICOM endpoints. |
Short Display | The network service providing retrieval for the images referenced in the imaging selection |
Cardinality | 0..* |
Type | Reference(Endpoint) |
Requirements | Access methods for retrieving (e.g., DICOM’s WADO-URI and WADO-RS) the selected images, frames, etc. |
Summary | true |
Comments | Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG) formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach. |
ImagingSelection.seriesUid | |
Element Id | ImagingSelection.seriesUid |
Definition | The Series Instance UID for the DICOM Series from which the images were selected. |
Short Display | DICOM Series Instance UID |
Cardinality | 0..1 |
Type | id |
Requirements | DICOM Series Instance UID. Required unless frameOfReferenceUid and imageRegion are present and instance is not present. |
Alternate Names | SeriesInstanceUID |
Summary | true |
Comments | See DICOM PS3.3 C.7.3 . |
ImagingSelection.seriesNumber | |
Element Id | ImagingSelection.seriesNumber |
Definition | The Series Number for the DICOM Series from which the images were selected. |
Short Display | DICOM Series Number |
Cardinality | 0..1 |
Type | unsignedInt |
Requirements | DICOM Series Number. |
Alternate Names | SeriesNumber |
Summary | true |
Comments | See DICOM PS3.3 C.7.3 . |
ImagingSelection.frameOfReferenceUid | |
Element Id | ImagingSelection.frameOfReferenceUid |
Definition | The Frame of Reference UID identifying the coordinate system that conveys spatial and/or temporal information for the selected images or frames. |
Short Display | The Frame of Reference UID for the selected images |
Cardinality | 0..1 |
Type | id |
Requirements | DICOM Frame of Reference UID. Required if studyInstanceUid and seriesInstanceUid are not present. |
Alternate Names | FrameOfReferenceUID |
Summary | true |
Comments | See DICOM PS3.3 C.7.4.1 . |
ImagingSelection.bodySite | |
Element Id | ImagingSelection.bodySite |
Definition | The anatomic structures examined. See DICOM Part 16 Annex L (http://dicom.nema.org/medical/dicom/current/output/chtml/part16/chapter_L.html) for DICOM to SNOMED-CT mappings. |
Short Display | Body part examined |
Cardinality | 0..1 |
Terminology Binding | SNOMED CT Body Structures (Example) |
Type | CodeableReference(BodyStructure) |
Alternate Names | BodyPartExamined |
Summary | true |
ImagingSelection.focus | |
Element Id | ImagingSelection.focus |
Definition | The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus. |
Short Display | Related resource that is the focus for the imaging selection |
Cardinality | 0..* |
Type | Reference(ImagingSelection) |
Summary | true |
Comments | An imaging selection may reference a DICOM resource that itself references other DICOM resources. e.g. a presentation state references a set of source images or frames. |
ImagingSelection.instance | |
Element Id | ImagingSelection.instance |
Definition | Each imaging selection includes one or more selected DICOM SOP instances. |
Short Display | The selected instances |
Cardinality | 0..* |
Requirements | Required if the the selection does not include all instances in the specified series. |
Summary | true |
ImagingSelection.instance.uid | |
Element Id | ImagingSelection.instance.uid |
Definition | The SOP Instance UID for the selected DICOM instance. |
Short Display | DICOM SOP Instance UID |
Cardinality | 1..1 |
Type | id |
Requirements | DICOM SOP Instance UID. |
Alternate Names | SOPInstanceUID |
Summary | true |
Comments | See DICOM PS3.3 C.12.1 . |
ImagingSelection.instance.number | |
Element Id | ImagingSelection.instance.number |
Definition | The Instance Number for the selected DICOM instance. |
Short Display | DICOM Instance Number |
Cardinality | 0..1 |
Type | unsignedInt |
Requirements | DICOM Instance Number. |
Alternate Names | InstanceNumber |
Summary | true |
Comments | See DICOM PS3.3 C.7.6.1 . Note: A multiframe instance has a single instance number with each frame identified by a frame number. |
ImagingSelection.instance.sopClass | |
Element Id | ImagingSelection.instance.sopClass |
Definition | The SOP Class UID for the selected DICOM instance. |
Short Display | DICOM SOP Class UID |
Cardinality | 0..1 |
Terminology Binding | sopClass : |
Type | Coding |
Requirements | DICOM SOP Class UID. |
Alternate Names | SOPClassUID |
Summary | false |
Comments | See DICOM PS3.3 C.12.1 . |
ImagingSelection.instance.subset | |
Element Id | ImagingSelection.instance.subset |
Definition | Selected subset of the SOP Instance. The content and format of the subset item is determined by the SOP Class of the selected instance. May be one of: - A list of frame numbers selected from a multiframe SOP Instance. - A list of Content Item Observation UID values selected from a DICOM SR or other structured document SOP Instance. - A list of segment numbers selected from a segmentation SOP Instance. - A list of Region of Interest (ROI) numbers selected from a radiotherapy structure set SOP Instance. |
Short Display | The selected subset of the SOP Instance |
Cardinality | 0..* |
Type | string |
Summary | false |
ImagingSelection.instance.imageRegion2D | |
Element Id | ImagingSelection.instance.imageRegion2D |
Definition | Each imaging selection instance or frame list might includes an image region, specified by a region type and a set of 2D coordinates. If the parent imagingSelection.instance contains a subset element of type frame, the image region applies to all frames in the subset list. |
Short Display | A specific 2D region in a DICOM image / frame |
Cardinality | 0..* |
Requirements | Shall not be present if the parent imagingSelection.instance is not an image. |
Summary | false |
ImagingSelection.instance.imageRegion2D.regionType | |
Element Id | ImagingSelection.instance.imageRegion2D.regionType |
Definition | Specifies the type of image region. |
Short Display | point | polyline | interpolated | circle | ellipse |
Cardinality | 1..1 |
Terminology Binding | Imaging Selection2 D Graphic Type (Required) |
Type | code |
Alternate Names | GraphicType |
Summary | false |
Comments | See DICOM PS3.3 C.10.5.1.2 . |
ImagingSelection.instance.imageRegion2D.coordinate | |
Element Id | ImagingSelection.instance.imageRegion2D.coordinate |
Definition | The coordinates describing the image region. Encoded as a set of (column, row) pairs that denote positions in the selected image / frames specified with sub-pixel resolution. The origin at the TLHC of the TLHC pixel is 0.0\0.0, the BRHC of the TLHC pixel is 1.0\1.0, and the BRHC of the BRHC pixel is the number of columns\rows in the image / frames. The values must be within the range 0\0 to the number of columns\rows in the image / frames. |
Short Display | Specifies the coordinates that define the image region |
Cardinality | 1..* |
Type | decimal |
Element Order Meaning | The values are an ordered set of (x, y) coordinates. |
Requirements | The number of values must be a multiple of two. |
Alternate Names | GraphicData |
Summary | false |
Comments | For a description of how 2D coordinates are encoded, see DICOM PS3.3 C.18.6 . |
ImagingSelection.instance.imageRegion3D | |
Element Id | ImagingSelection.instance.imageRegion3D |
Definition | Each imaging selection might includes a 3D image region, specified by a region type and a set of 3D coordinates. |
Short Display | A specific 3D region in a DICOM frame of reference |
Cardinality | 0..* |
Requirements | Requires that the ImagingSelection.frameOfReferenceUid element is present. |
Summary | false |
ImagingSelection.instance.imageRegion3D.regionType | |
Element Id | ImagingSelection.instance.imageRegion3D.regionType |
Definition | Specifies the type of image region. |
Short Display | point | multipoint | polyline | polygon | ellipse | ellipsoid |
Cardinality | 1..1 |
Terminology Binding | Imaging Selection3 D Graphic Type (Required) |
Type | code |
Alternate Names | GraphicType |
Summary | false |
Comments | See DICOM PS3.3 C.18.9.1.2 . |
ImagingSelection.instance.imageRegion3D.coordinate | |
Element Id | ImagingSelection.instance.imageRegion3D.coordinate |
Definition | The coordinates describing the image region. Encoded as an ordered set of (x,y,z) triplets (in mm and may be negative) that define a region of interest in the patient-relative Reference Coordinate System defined by ImagingSelection.frameOfReferenceUid element. |
Short Display | Specifies the coordinates that define the image region |
Cardinality | 1..* |
Type | decimal |
Element Order Meaning | The values are an ordered set of (x, y, z) coordinates. |
Requirements | The number of values must be a multiple of three. |
Alternate Names | GraphicData |
Summary | false |
Comments | For a description of how 3D coordinates are encoded, see DICOM PS3.3 C.18.9 . |