Search parameters for the Resource DeviceRequest - Search Parameters resource. Also check the Extensions registry for search parameters
on extensions related to this resource.
http://hl7.org/fhir/SearchParameter/DeviceRequest-authored-on
12.24.14 authored-on Parameter authored-on
:date
When the request transitioned to being actionable
Resource DeviceRequest
Expression
DeviceRequest.authoredOn
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
Comparators
Allowed: eq, ne, gt, ge, lt, le, sa, eb, ap
http://hl7.org/fhir/SearchParameter/DeviceRequest-based-on
12.24.15 based-on Parameter based-on
:reference
Plan/proposal/order fulfilled by this request
Resource DeviceRequest
Expression
DeviceRequest.basedOn
Processing Mode
Normal
Target Resources
Account , ActivityDefinition , ActorDefinition , AdministrableProductDefinition , AdverseEvent , AllergyIntolerance , Appointment , AppointmentResponse , ArtifactAssessment , AuditEvent , Basic , Binary , BiologicallyDerivedProduct , BiologicallyDerivedProductDispense , BodyStructure , Bundle , CapabilityStatement , CarePlan , CareTeam , ChargeItem , ChargeItemDefinition , Citation , Claim , ClaimResponse , ClinicalImpression , ClinicalUseDefinition , CodeSystem , Communication , CommunicationRequest , CompartmentDefinition , Composition , ConceptMap , Condition , ConditionDefinition , Consent , Contract , Coverage , CoverageEligibilityRequest , CoverageEligibilityResponse , DetectedIssue , Device , DeviceAssociation , DeviceDefinition , DeviceDispense , DeviceMetric , DeviceRequest , DeviceUsage , DiagnosticReport , DocumentReference , Encounter , EncounterHistory , Endpoint , EnrollmentRequest , EnrollmentResponse , EpisodeOfCare , EventDefinition , Evidence , EvidenceReport , EvidenceVariable , ExampleScenario , ExplanationOfBenefit , FamilyMemberHistory , Flag , FormularyItem , GenomicStudy , Goal , GraphDefinition , Group , GuidanceResponse , HealthcareService , ImagingSelection , ImagingStudy , Immunization , ImmunizationEvaluation , ImmunizationRecommendation , ImplementationGuide , Ingredient , InsurancePlan , InventoryItem , InventoryReport , Invoice , Library , Linkage , List , Location , ManufacturedItemDefinition , Measure , MeasureReport , Medication , MedicationAdministration , MedicationDispense , MedicationKnowledge , MedicationRequest , MedicationStatement , MedicinalProductDefinition , MessageDefinition , MessageHeader , MolecularSequence , NamingSystem , NutritionIntake , NutritionOrder , NutritionProduct , Observation , ObservationDefinition , OperationDefinition , OperationOutcome , Organization , OrganizationAffiliation , PackagedProductDefinition , Parameters , Patient , PaymentNotice , PaymentReconciliation , Permission , Person , PlanDefinition , Practitioner , PractitionerRole , Procedure , Provenance , Questionnaire , QuestionnaireResponse , RegulatedAuthorization , RelatedPerson , RequestOrchestration , Requirements , ResearchStudy , ResearchSubject , RiskAssessment , Schedule , SearchParameter , ServiceRequest , Slot , Specimen , SpecimenDefinition , StructureDefinition , StructureMap , Subscription , SubscriptionStatus , SubscriptionTopic , Substance , SubstanceDefinition , SubstanceNucleicAcid , SubstancePolymer , SubstanceProtein , SubstanceReferenceInformation , SubstanceSourceMaterial , SupplyDelivery , SupplyRequest , Task , TerminologyCapabilities , TestPlan , TestReport , TestScript , Transport , ValueSet , VerificationResult , VisionPrescription
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/clinical-code
This search parameter is part of the common search parameter clinical-code
12.24.16 code Parameter code
:token
Resource DeviceRequest
Expression
DeviceRequest.code.concept
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/DeviceRequest-device
12.24.17 device Parameter device
:reference
Reference to resource that is being requested/ordered
Resource DeviceRequest
Expression
DeviceRequest.code.reference
Processing Mode
Normal
Target Resources
Device , DeviceDefinition
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/clinical-encounter
This search parameter is part of the common search parameter clinical-encounter
12.24.18 encounter Parameter encounter
:reference
Resource DeviceRequest
Expression
DeviceRequest.encounter
Processing Mode
Normal
Target Resources
Encounter
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/DeviceRequest-event-date
12.24.19 event-date Parameter event-date
:date
When service should occur
Resource DeviceRequest
Expression
(DeviceRequest.occurrence.ofType(dateTime)) | (DeviceRequest.occurrence.ofType(Period))
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
Comparators
Allowed: eq, ne, gt, ge, lt, le, sa, eb, ap
http://hl7.org/fhir/SearchParameter/DeviceRequest-group-identifier
12.24.20 group-identifier Parameter group-identifier
:token
Composite request this is part of
Resource DeviceRequest
Expression
DeviceRequest.groupIdentifier
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/clinical-identifier
This search parameter is part of the common search parameter clinical-identifier
12.24.21 identifier Parameter identifier
:token
Resource DeviceRequest
Expression
DeviceRequest.identifier
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/DeviceRequest-instantiates-canonical
12.24.22 instantiates-canonical Parameter instantiates-canonical
:reference
Instantiates FHIR protocol or definition
Resource DeviceRequest
Expression
DeviceRequest.instantiatesCanonical
Processing Mode
Normal
Target Resources
ActivityDefinition , PlanDefinition
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/DeviceRequest-instantiates-uri
12.24.23 instantiates-uri Parameter instantiates-uri
:uri
Instantiates external protocol or definition
Resource DeviceRequest
Expression
DeviceRequest.instantiatesUri
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/DeviceRequest-insurance
12.24.24 insurance Parameter insurance
:reference
Associated insurance coverage
Resource DeviceRequest
Expression
DeviceRequest.insurance
Processing Mode
Normal
Target Resources
ClaimResponse , Coverage
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/DeviceRequest-intent
12.24.25 intent Parameter intent
:token
proposal | plan | original-order |reflex-order
Resource DeviceRequest
Expression
DeviceRequest.intent
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/clinical-patient
This search parameter is part of the common search parameter clinical-patient
12.24.26 patient Parameter patient
:reference
Resource DeviceRequest
Expression
DeviceRequest.subject.where(resolve() is Patient)
Processing Mode
Normal
Target Resources
Patient
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/DeviceRequest-performer
12.24.27 performer Parameter performer
:reference
Desired performer for service
http://hl7.org/fhir/SearchParameter/DeviceRequest-performer-code
12.24.28 performer-code Parameter performer-code
:token
Desired performer for service
Resource DeviceRequest
Expression
DeviceRequest.performer.concept
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/DeviceRequest-prior-request
12.24.29 prior-request Parameter prior-request
:reference
Request takes the place of referenced completed or terminated requests
Resource DeviceRequest
Expression
DeviceRequest.replaces
Processing Mode
Normal
Target Resources
DeviceRequest
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/DeviceRequest-requester
12.24.30 requester Parameter requester
:reference
Who/what is requesting service
Resource DeviceRequest
Expression
DeviceRequest.requester
Processing Mode
Normal
Target Resources
Device , Organization , PractitionerRole , Practitioner
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/DeviceRequest-status
12.24.31 status Parameter status
:token
entered-in-error | draft | active |suspended | completed
Resource DeviceRequest
Expression
DeviceRequest.status
Processing Mode
Normal
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/DeviceRequest-subject
12.24.32 subject Parameter subject
:reference
Individual the service is ordered for
Resource DeviceRequest
Expression
DeviceRequest.subject
Processing Mode
Normal
Target Resources
Device , Group , Location , Patient
Multiples
multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true