Publish-box (todo)
Orders and Observations Work Group | Maturity Level: 2 | Trial Use | Security Category: Business | Compartments: No defined compartments |
A type of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device.
This is a base resource that tracks individual instances of a device and their location. It is referenced by other resources for recording which device performed an action such as a procedure or an observation, which device was implanted in or explanted from a patient, dispensing a device to a patient for their use, managing inventory, or when requesting a specific device for a patient's use. Medical devices include durable (reusable) medical equipment, implantable devices, as well as disposable equipment used for diagnostic, treatment, and research for healthcare and public health. Medical devices may also include some types of software.
Non-medical devices may include items such as a machine, cellphone, computer, software application or algorithm, etc. In short, a Device can range from a tongue depressor to an MRI. The fields in the Device resource must be flexible enough to cover this range.
The resource may be used to document the Unique Device Identifier (UDI) and information about a device where appropriate or necessary according to local jurisdictions over time. Additional information about UDI is provided in the Unique Device Identifier (UDI) section.
Devices may be categorized and may be associated with one or more categories. Device category examples include, but are not limited to: active, communicating, durable medical equipment, home use, implantable, InVitro diagnostics, personal health, point-of-care, single use, re-usable, and software.
'Active device' means any device, the operation of which depends on a source of energy other than that generated by the human body for that purpose, or by gravity, and which acts by changing the density of or converting that energy. Devices intended to transmit energy, substances or other elements between an active device and the patient, without any significant change, shall not be deemed to be active devices. Software shall also be deemed to be an active device. MDR (EU) 2017/745
Active Implantable Medical Devices include the definition for both active devices and implantable devices (see below). Examples include: Implantable cardiac pacemakers; Implantable defibrillator; Implantable neurostimulator systems; Leads, electrodes, adaptors for implantable pulse generators; Brachytherapy systems; Ventricular Assist Devices (VADs); Cochlear implants; Implantable infusion pumps; Implantable glucose monitors; Micro Electro-Mechanical Systems (MEMS); and their accessories where applicable.
This category of devices communicates electronically to peer information systems or possibly another device. In addition to patient observations for use by clinicians in providing care and for building a health record, the device communicates metadata about its own state and the protocol used to transfer that information.
To support the use and evaluate the reliability of the patient data, it is important to to collect and record data about the identity and operational status of the device that generated the observations. The Device resource is an important locus for such information. The information it generates for clinical and other purposes goes into other resources such as the Observation or Medication resource depending upon what the device does. To support device-related information about Communicating Medical Devices the Device resource needs to have elements that describe not only the basic information like the serial number, manufacturer name and model number, but information about the protocol, its version, its certification, the properties it has to perform its purposed tasks such as internal clocks, synchronization state, resolution, etc.
Equipment and supplies that provides therapeutic benefits to a patient in need because of certain medical conditions and/or illnesses, and which are ordered by a health care provider for everyday or extended use.
Examples include: oxygen equipment, suction pumps, traction equipment, home infusion services, continuous positive airway pressure (CPAP) devices, hospital beds, wheelchairs, crutches walkers, canes, or blood testing strips and meters for diabetics.
A home use medical device is a medical device intended for users in any environment outside of a professional healthcare facility. This includes devices intended for use in both professional healthcare facilities and homes.
US Food and Drug Administration Center for Devices and Radiological Health. Home Use Devices. Accessed 12 May 2022
Implant means a device that is placed into a surgically or naturally formed cavity of the human body. A device is regarded as an implant for the purpose of this part only if it is intended to remain implanted continuously for a period of 30 days or more, unless the Commissioner determines otherwise to protect human health. 21CFR Part 860.3 Accessed 12 May 2022
'implantable device' means any device, including those that are partially or wholly absorbed, which is intended:
by clinical intervention and which is intended to remain in place after the procedure.
Any device intended to be partially introduced into the human body by clinical intervention and intended to remain in place after the procedure for at least 30 days shall also be deemed to be an implantable device; MDR (EU) 2017/745 Accessed 12 May 2022
In vitro diagnostics (IVD) are tests done on samples such as blood or tissue that have been taken from the human body. In vitro diagnostics can detect diseases or other conditions, and can be used to monitor a person 's overall health to help cure, treat, or prevent diseases.
In vitro diagnostics may also be used in precision medicine to identify patients who are likely to benefit from specific treatments or therapies. These in vitro diagnostics can include next generation sequencing tests, which scan a person 's DNA to detect genomic variations.
Some tests are used in laboratory or other health professional settings and other tests are for consumers to use at home. US Food and Drug Administration Center for Devices and Radiological Health In Vitro Diagnostics and Drug Administration Center for Devices and Radiological Health In Vitro Diagnostics Accessed 12 May 2022
Patient-use, or home use devices, intended for users in any environment outside of a professional healthcare facility. This includes devices intended for use in both professional healthcare facilities and homes US Food and Drug Administration Center for Devices and Radiological Health. Home Use Devices. Accessed 13 March 2020. PHDs are the subset of patient-use devices that report their information to a peer via a protocol.
One class of communicating devices is the Personal Health Device or PHD. PHDs are medical devices that can be used by patients or others who are typically not medical professions, to gather patient observations and information. These devices can often be purchased in department stores or online by anyone. They may be regulated as medical devices, or not.
PHDs include the popular fitness trackers often combined with heart rate monitors, but also blood pressure monitors, weight scales, pulse oximeters, thermometers, and, for those that require them, glucose meters. Over time more sophisticated devices such as continuous glucose monitors, insulin pumps, vital signs monitors including ECGs, and even spirometers are entering the PHD consumer market. These devices communicate measurement data and data about themselves via a digital transport protocol to some peer entity, often a mobile phone or tablet. The protocol may follow a standard but most protocols are proprietary. In either case, it is common practice for manufacturers to provide free applications that run on these mobile platforms for the purpose of communicating with their devices.
The fields populated in the Device resource by PHDs, typically via a gateway, is the information a PHD reports about itself electronically. There is no input by the patient except for information the patient may enter on the device through some UI. This device reporting capability distinguishes communicating PHDs from the general set of patient-use devices.
PoCDs are of another level of complexity compared to PHDs: they include devices like multi-parameter physiological patient monitors, anesthesia workstations, infusion pumps and numerous other kinds of devices that provide near-real-time information about patient condition or therapy, potentially including dozens or hundreds of variables coming from a single device system. They may be structurally complex, involving multiple subsystems that are themselves complex, such as a ventilator or gas analyzer functioning within an anesthesia workstation, or pluggable modules in a patient monitor controlling invasive blood pressure or gathering EEG data.
Information systems using such data need to be able to understand the structure and dynamic state of the devices originating them, generally requiring access to what is in effect a dynamically changing model of the device and its subsystems and measuring capabilities. This requires more than a single Device resource - a hierarchy of Device resources is constructed carrying data about the top-level containing device (for example a monitor), and a hierarchy of contained Device resources representing subsystems (in the monitor, builtin and attached modular measurement capabilities), channels, and DeviceMetric resources representing individual measurements or computations.
A device that is intended to be used on one individual during a single procedure; MDR (EU) 2017/745 Accessed 12 May 2022
Reusable medical devices are devices that health care providers can reuse to diagnose and treat one or multiple patients. Examples of reusable medical devices include surgical forceps, endoscopes and laryngoscopes. US Food and Drug Administration Center for Devices and Radiological Health Reusable Medical Devices
The Device resource is intended to represent an instance of a software component or application. A software item like a data transformer or converter, or a clinical support algorithm, may be an independently deployed, managed and configured entity that contributes to patient care and needs to be documented just a surely as, say, a physical cardiac monitor. The FHIR Device resource can contain instance data such as version information and operational attributes. It can also represent the relationship of the software item to other device and information system components through reference linkages. This category includes software regardless of whether or not is regulated. Device resource instances documenting software items are important to traceability of data and analyzing adverse events, and so have important patient safety roles.
When referring to a specific instance, even without specific instance details, Device is to be used, not a DeviceDefinition. The context of a data exchange indicates whether the data is representing a physical instance or a "kind", not the presence of instance data such as lot and serial numbers.
Some examples:
Note to Implementers: The module pages under development by Orders and Observations will further describe the variations of device use cases across the device resources, e.g., Device, DeviceDefinition, DeviceAssociation, DeviceDispense, DeviceMetric, DeviceRequest, and Device Usage.
These are the device related resources
In FHIR, the Device represents either the device in total, or a component of an encapsulating device when there is a need for individual tracking of a component. A Device as a component then points to the parent device it is part of. The top-level Device captures the actual data about the instance of the device and the instances of all its children that either provides identifying characteristics of the Device (including applicable UDI – unique device identification) and data that can vary dynamically by device, e.g., specific settings at a particular point in time.
The DeviceMetric models the properties of the Observations generated by the device, such as whether or not the Observation is a setting.
Devices differ from medications because they are not "used up" - they remain active in or for a patient for a longer duration. They also may be re-used, particularly non-implanted devices and those used for diagnostics and procedures. Frequently, when a device is packaged with a medication, the ordering, dispense, and administration processes typically focus on the medication aspects and reference the device.
In the case of an infusion pump, while some actions are focused on the device (e.g., ordering to a room or maintaining the pump), the focus is as well on the medication while the device is used for administration. However, that separation is not always as clear and may be impacted by specific implementations. Regardless, the Medication resource should not be used to represent (implanted) devices, rather reference the relationship where an actual device needs to be tracked in addition to the medication. In some sense the Medication is analogous to the Observation generated by a Blood Pressure personal health device. The Observation resource contains the blood pressure values, units and the time stamp while the Device resource contains the manufacturer name, model number, serial number, firmware and hardware versions, exchange protocol information, any clock capabilities, etc.
Structure
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | TU | DomainResource | Item used in healthcare + Rule: only one Device.name.display SHALL be true when there is more than one Device.name Elements defined in Ancestors: id, meta, implicitRules, language, text, contained, extension, modifierExtension | |
identifier | 0..* | Identifier | Instance identifier | |
definition | 0..1 | CodeableReference(DeviceDefinition) | The reference to the definition for the device Binding: Device Type (Required) | |
udiCarrier | Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string |
deviceIdentifier | Σ | 1..1 | string | Mandatory fixed portion of UDI |
deviceIdentifierSystem | 0..1 | uri | The namespace for the device identifier value | |
issuer | Σ | 1..1 | uri | UDI Issuing Organization |
jurisdiction | 0..1 | uri | Regional UDI authority | |
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String |
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String |
entryType | 0..1 | code | barcode | rfid | manual | card | self-reported | electronic-transmission | unknown Binding: UDI Entry Type (Required) | |
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error Binding: FHIR Device Status (Required) |
availabilityStatus | 0..1 | CodeableConcept | lost | damaged | destroyed | available Binding: FHIR Device Availability Status (Extensible) | |
biologicalSourceEvent | 0..1 | Identifier | An identifier that supports traceability to the event during which material in this product from one or more biological entities was obtained or pooled | |
manufacturer | 0..1 | string | Name of device manufacturer | |
manufactureDate | 0..1 | dateTime | Date when the device was made | |
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
lotNumber | 0..1 | string | Lot number of manufacture | |
serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |
name | C | 0..* | BackboneElement | The name or names of the device as known to the manufacturer and/or patient |
value | Σ | 1..1 | string | The term that names the device |
type | Σ | 1..1 | CodeableConcept | registered-name | user-friendly-name | patient-reported-name Binding: Device Name Type (Extensible) |
display | ?!ΣC | 0..1 | boolean | The preferred device name |
modelNumber | 0..1 | string | The manufacturer's model number for the device | |
partNumber | 0..1 | string | The part number or catalog number of the device | |
category | 0..* | CodeableConcept | Indicates a high-level grouping of the device Binding: FHIR Device Category (Example) | |
type | 0..* | CodeableConcept | The kind or type of device Binding: Device Type (Example) | |
deviceVersion | 0..* | BackboneElement | The actual design of the device or software version running on the device | |
type | 0..1 | CodeableConcept | The type of the device version, e.g. manufacturer, approved, internal Binding: Device Version Type (Example) | |
component | 0..1 | Identifier | The hardware or software module of the device to which the version applies | |
installDate | 0..1 | dateTime | The date the version was installed on the device | |
value | 1..1 | string | The version text | |
conformsTo | 0..* | BackboneElement | Identifies the standards, specifications, or formal guidances for the capabilities supported by the device | |
category | 0..1 | CodeableConcept | Describes the common type of the standard, specification, or formal guidance. communication | performance | measurement Binding: Device Specification Category (Example) | |
specification | 1..1 | CodeableConcept | Identifies the standard, specification, or formal guidance that the device adheres to Binding: Device Specification Type (Example) | |
version | 0..1 | string | Specific form or variant of the standard | |
property | 0..* | BackboneElement | Inherent, essentially fixed, characteristics of the device. e.g., time properties, size, material, etc. | |
type | 1..1 | CodeableConcept | Code that specifies the property being represented Binding: Device Property Type (Example) | |
value[x] | 1..1 | Value of the property | ||
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueAttachment | Attachment | |||
mode | 0..1 | CodeableConcept | The designated condition for performing a task Binding: FHIR Device Operation Mode (Example) | |
cycle | 0..1 | Count | The series of occurrences that repeats during the operation of the device | |
duration | 0..1 | Duration | A measurement of time during the device's operation (e.g., days, hours, mins, etc.) | |
owner | 0..1 | Reference(Organization) | Organization responsible for device | |
contact | 0..* | ContactPoint | Details for human/organization for support | |
location | 0..1 | Reference(Location) | Where the device is found | |
url | 0..1 | uri | Network address to contact device | |
endpoint | 0..* | Reference(Endpoint) | Technical endpoints providing access to electronic services provided by the device | |
gateway | 0..* | CodeableReference(Device) | Linked device acting as a communication/data collector, translator or controller | |
note | 0..* | Annotation | Device notes and comments | |
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device Binding: Device Safety (Example) |
parent | 0..1 | Reference(Device) | The higher level or encompassing device that this device is a logical part of | |
Documentation for this format |
See the Extensions for this resource
UML Diagram (Legend)
XML Template
<Device xmlns="http://hl7.org/fhir"> <!-- from Resource: id, meta, implicitRules, and language --> <!-- from DomainResource: text, contained, extension, and modifierExtension --> <identifier><!-- 0..* Identifier Instance identifier --></identifier> <definition><!-- 0..1 CodeableReference(DeviceDefinition) The reference to the definition for the device --></definition> <udiCarrier> <!-- 0..* Unique Device Identifier (UDI) Barcode string --> <deviceIdentifier value="[string]"/><!-- 1..1 Mandatory fixed portion of UDI --> <deviceIdentifierSystem value="[uri]"/><!-- 0..1 The namespace for the device identifier value --> <issuer value="[uri]"/><!-- 1..1 UDI Issuing Organization --> <jurisdiction value="[uri]"/><!-- 0..1 Regional UDI authority --> <carrierAIDC value="[base64Binary]"/><!-- 0..1 UDI Machine Readable Barcode String --> <carrierHRF value="[string]"/><!-- 0..1 UDI Human Readable Barcode String --> <entryType value="[code]"/><!-- 0..1 barcode | rfid | manual | card | self-reported | electronic-transmission | unknown --> </udiCarrier> <status value="[code]"/><!-- 0..1 active | inactive | entered-in-error --> <availabilityStatus><!-- 0..1 CodeableConcept lost | damaged | destroyed | available --></availabilityStatus> <biologicalSourceEvent><!-- 0..1 Identifier An identifier that supports traceability to the event during which material in this product from one or more biological entities was obtained or pooled --></biologicalSourceEvent> <manufacturer value="[string]"/><!-- 0..1 Name of device manufacturer --> <manufactureDate value="[dateTime]"/><!-- 0..1 Date when the device was made --> <expirationDate value="[dateTime]"/><!-- 0..1 Date and time of expiry of this device (if applicable) --> <lotNumber value="[string]"/><!-- 0..1 Lot number of manufacture --> <serialNumber value="[string]"/><!-- 0..1 Serial number assigned by the manufacturer --> <name> <!-- I 0..* The name or names of the device as known to the manufacturer and/or patient --> <value value="[string]"/><!-- 1..1 The term that names the device --> <type><!-- 1..1 CodeableConcept registered-name | user-friendly-name | patient-reported-name --></type> <display value="[boolean]"/><!-- I 0..1 The preferred device name --> </name> <modelNumber value="[string]"/><!-- 0..1 The manufacturer's model number for the device --> <partNumber value="[string]"/><!-- 0..1 The part number or catalog number of the device --> <category><!-- 0..* CodeableConcept Indicates a high-level grouping of the device --></category> <type><!-- 0..* CodeableConcept The kind or type of device --></type> <deviceVersion> <!-- 0..* The actual design of the device or software version running on the device --> <type><!-- 0..1 CodeableConcept The type of the device version, e.g. manufacturer, approved, internal --></type> <component><!-- 0..1 Identifier The hardware or software module of the device to which the version applies --></component> <installDate value="[dateTime]"/><!-- 0..1 The date the version was installed on the device --> <value value="[string]"/><!-- 1..1 The version text --> </deviceVersion> <conformsTo> <!-- 0..* Identifies the standards, specifications, or formal guidances for the capabilities supported by the device --> <category><!-- 0..1 CodeableConcept Describes the common type of the standard, specification, or formal guidance. communication | performance | measurement --></category> <specification><!-- 1..1 CodeableConcept Identifies the standard, specification, or formal guidance that the device adheres to --></specification> <version value="[string]"/><!-- 0..1 Specific form or variant of the standard --> </conformsTo> <property> <!-- 0..* Inherent, essentially fixed, characteristics of the device. e.g., time properties, size, material, etc. --> <type><!-- 1..1 CodeableConcept Code that specifies the property being represented --></type> <value[x]><!-- 1..1 Quantity|CodeableConcept|string|boolean|integer|Range| Attachment Value of the property --></value[x]> </property> <mode><!-- 0..1 CodeableConcept The designated condition for performing a task --></mode> <cycle><!-- 0..1 Count The series of occurrences that repeats during the operation of the device --></cycle> <duration><!-- 0..1 Duration A measurement of time during the device's operation (e.g., days, hours, mins, etc.) --></duration> <owner><!-- 0..1 Reference(Organization) Organization responsible for device --></owner> <contact><!-- 0..* ContactPoint Details for human/organization for support --></contact> <location><!-- 0..1 Reference(Location) Where the device is found --></location> <url value="[uri]"/><!-- 0..1 Network address to contact device --> <endpoint><!-- 0..* Reference(Endpoint) Technical endpoints providing access to electronic services provided by the device --></endpoint> <gateway><!-- 0..* CodeableReference(Device) Linked device acting as a communication/data collector, translator or controller --></gateway> <note><!-- 0..* Annotation Device notes and comments --></note> <safety><!-- 0..* CodeableConcept Safety Characteristics of Device --></safety> <parent><!-- 0..1 Reference(Device) The higher level or encompassing device that this device is a logical part of --></parent> </Device>
JSON Template
{ "resourceType" : "Device", // from Resource: id, meta, implicitRules, and language // from DomainResource: text, contained, extension, and modifierExtension "identifier" : [{ Identifier }], // Instance identifier "definition" : { CodeableReference(DeviceDefinition) }, // The reference to the definition for the device "udiCarrier" : [{ // Unique Device Identifier (UDI) Barcode string "deviceIdentifier" : "<string>", // R! Mandatory fixed portion of UDI "deviceIdentifierSystem" : "<uri>", // The namespace for the device identifier value "issuer" : "<uri>", // R! UDI Issuing Organization "jurisdiction" : "<uri>", // Regional UDI authority "carrierAIDC" : "<base64Binary>", // UDI Machine Readable Barcode String "carrierHRF" : "<string>", // UDI Human Readable Barcode String "entryType" : "<code>" // barcode | rfid | manual | card | self-reported | electronic-transmission | unknown }], "status" : "<code>", // active | inactive | entered-in-error "availabilityStatus" : { CodeableConcept }, // lost | damaged | destroyed | available "biologicalSourceEvent" : { Identifier }, // An identifier that supports traceability to the event during which material in this product from one or more biological entities was obtained or pooled "manufacturer" : "<string>", // Name of device manufacturer "manufactureDate" : "<dateTime>", // Date when the device was made "expirationDate" : "<dateTime>", // Date and time of expiry of this device (if applicable) "lotNumber" : "<string>", // Lot number of manufacture "serialNumber" : "<string>", // Serial number assigned by the manufacturer "name" : [{ // I The name or names of the device as known to the manufacturer and/or patient "value" : "<string>", // R! The term that names the device "type" : { CodeableConcept }, // R! registered-name | user-friendly-name | patient-reported-name "display" : <boolean> // I The preferred device name }], "modelNumber" : "<string>", // The manufacturer's model number for the device "partNumber" : "<string>", // The part number or catalog number of the device "category" : [{ CodeableConcept }], // Indicates a high-level grouping of the device "type" : [{ CodeableConcept }], // The kind or type of device "deviceVersion" : [{ // The actual design of the device or software version running on the device "type" : { CodeableConcept }, // The type of the device version, e.g. manufacturer, approved, internal "component" : { Identifier }, // The hardware or software module of the device to which the version applies "installDate" : "<dateTime>", // The date the version was installed on the device "value" : "<string>" // R! The version text }], "conformsTo" : [{ // Identifies the standards, specifications, or formal guidances for the capabilities supported by the device "category" : { CodeableConcept }, // Describes the common type of the standard, specification, or formal guidance. communication | performance | measurement "specification" : { CodeableConcept }, // R! Identifies the standard, specification, or formal guidance that the device adheres to "version" : "<string>" // Specific form or variant of the standard }], "property" : [{ // Inherent, essentially fixed, characteristics of the device. e.g., time properties, size, material, etc. "type" : { CodeableConcept }, // R! Code that specifies the property being represented // value[x]: Value of the property. One of these 7: "valueQuantity" : { Quantity }, "valueCodeableConcept" : { CodeableConcept }, "valueString" : "<string>", "valueBoolean" : <boolean>, "valueInteger" : <integer>, "valueRange" : { Range }, "valueAttachment" : { Attachment } }], "mode" : { CodeableConcept }, // The designated condition for performing a task "cycle" : { Count }, // The series of occurrences that repeats during the operation of the device "duration" : { Duration }, // A measurement of time during the device's operation (e.g., days, hours, mins, etc.) "owner" : { Reference(Organization) }, // Organization responsible for device "contact" : [{ ContactPoint }], // Details for human/organization for support "location" : { Reference(Location) }, // Where the device is found "url" : "<uri>", // Network address to contact device "endpoint" : [{ Reference(Endpoint) }], // Technical endpoints providing access to electronic services provided by the device "gateway" : [{ CodeableReference(Device) }], // Linked device acting as a communication/data collector, translator or controller "note" : [{ Annotation }], // Device notes and comments "safety" : [{ CodeableConcept }], // Safety Characteristics of Device "parent" : { Reference(Device) } // The higher level or encompassing device that this device is a logical part of }
Turtle Template
@prefix fhir: <http://hl7.org/fhir/> . [ a fhir:Device; fhir:nodeRole fhir:treeRoot; # if this is the parser root # from Resource: .id, .meta, .implicitRules, and .language # from DomainResource: .text, .contained, .extension, and .modifierExtension fhir:identifier ( [ Identifier ] ... ) ; # 0..* Instance identifier fhir:definition [ CodeableReference(DeviceDefinition) ] ; # 0..1 The reference to the definition for the device fhir:udiCarrier ( [ # 0..* Unique Device Identifier (UDI) Barcode string fhir:deviceIdentifier [ string ] ; # 1..1 Mandatory fixed portion of UDI fhir:deviceIdentifierSystem [ uri ] ; # 0..1 The namespace for the device identifier value fhir:issuer [ uri ] ; # 1..1 UDI Issuing Organization fhir:jurisdiction [ uri ] ; # 0..1 Regional UDI authority fhir:carrierAIDC [ base64Binary ] ; # 0..1 UDI Machine Readable Barcode String fhir:carrierHRF [ string ] ; # 0..1 UDI Human Readable Barcode String fhir:entryType [ code ] ; # 0..1 barcode | rfid | manual | card | self-reported | electronic-transmission | unknown ] ... ) ; fhir:status [ code ] ; # 0..1 active | inactive | entered-in-error fhir:availabilityStatus [ CodeableConcept ] ; # 0..1 lost | damaged | destroyed | available fhir:biologicalSourceEvent [ Identifier ] ; # 0..1 An identifier that supports traceability to the event during which material in this product from one or more biological entities was obtained or pooled fhir:manufacturer [ string ] ; # 0..1 Name of device manufacturer fhir:manufactureDate [ dateTime ] ; # 0..1 Date when the device was made fhir:expirationDate [ dateTime ] ; # 0..1 Date and time of expiry of this device (if applicable) fhir:lotNumber [ string ] ; # 0..1 Lot number of manufacture fhir:serialNumber [ string ] ; # 0..1 Serial number assigned by the manufacturer fhir:name ( [ # 0..* I The name or names of the device as known to the manufacturer and/or patient fhir:value [ string ] ; # 1..1 The term that names the device fhir:type [ CodeableConcept ] ; # 1..1 registered-name | user-friendly-name | patient-reported-name fhir:display [ boolean ] ; # 0..1 I The preferred device name ] ... ) ; fhir:modelNumber [ string ] ; # 0..1 The manufacturer's model number for the device fhir:partNumber [ string ] ; # 0..1 The part number or catalog number of the device fhir:category ( [ CodeableConcept ] ... ) ; # 0..* Indicates a high-level grouping of the device fhir:type ( [ CodeableConcept ] ... ) ; # 0..* The kind or type of device fhir:deviceVersion ( [ # 0..* The actual design of the device or software version running on the device fhir:type [ CodeableConcept ] ; # 0..1 The type of the device version, e.g. manufacturer, approved, internal fhir:component [ Identifier ] ; # 0..1 The hardware or software module of the device to which the version applies fhir:installDate [ dateTime ] ; # 0..1 The date the version was installed on the device fhir:value [ string ] ; # 1..1 The version text ] ... ) ; fhir:conformsTo ( [ # 0..* Identifies the standards, specifications, or formal guidances for the capabilities supported by the device fhir:category [ CodeableConcept ] ; # 0..1 Describes the common type of the standard, specification, or formal guidance. communication | performance | measurement fhir:specification [ CodeableConcept ] ; # 1..1 Identifies the standard, specification, or formal guidance that the device adheres to fhir:version [ string ] ; # 0..1 Specific form or variant of the standard ] ... ) ; fhir:property ( [ # 0..* Inherent, essentially fixed, characteristics of the device. e.g., time properties, size, material, etc. fhir:type [ CodeableConcept ] ; # 1..1 Code that specifies the property being represented # value[x] : 1..1 Value of the property. One of these 7 fhir:value [ a fhir:Quantity ; Quantity ] fhir:value [ a fhir:CodeableConcept ; CodeableConcept ] fhir:value [ a fhir:string ; string ] fhir:value [ a fhir:boolean ; boolean ] fhir:value [ a fhir:integer ; integer ] fhir:value [ a fhir:Range ; Range ] fhir:value [ a fhir:Attachment ; Attachment ] ] ... ) ; fhir:mode [ CodeableConcept ] ; # 0..1 The designated condition for performing a task fhir:cycle [ Count ] ; # 0..1 The series of occurrences that repeats during the operation of the device fhir:duration [ Duration ] ; # 0..1 A measurement of time during the device's operation (e.g., days, hours, mins, etc.) fhir:owner [ Reference(Organization) ] ; # 0..1 Organization responsible for device fhir:contact ( [ ContactPoint ] ... ) ; # 0..* Details for human/organization for support fhir:location [ Reference(Location) ] ; # 0..1 Where the device is found fhir:url [ uri ] ; # 0..1 Network address to contact device fhir:endpoint ( [ Reference(Endpoint) ] ... ) ; # 0..* Technical endpoints providing access to electronic services provided by the device fhir:gateway ( [ CodeableReference(Device) ] ... ) ; # 0..* Linked device acting as a communication/data collector, translator or controller fhir:note ( [ Annotation ] ... ) ; # 0..* Device notes and comments fhir:safety ( [ CodeableConcept ] ... ) ; # 0..* Safety Characteristics of Device fhir:parent [ Reference(Device) ] ; # 0..1 The higher level or encompassing device that this device is a logical part of ]
Changes from both R4 and R4B
Device | |
Device.definition |
|
Device.udiCarrier.deviceIdentifier |
|
Device.udiCarrier.deviceIdentifierSystem |
|
Device.udiCarrier.issuer |
|
Device.udiCarrier.entryType |
|
Device.status |
|
Device.availabilityStatus |
|
Device.biologicalSourceEvent |
|
Device.name |
|
Device.name.value |
|
Device.name.type |
|
Device.name.display |
|
Device.category |
|
Device.type |
|
Device.deviceVersion |
|
Device.deviceVersion.type |
|
Device.deviceVersion.component |
|
Device.deviceVersion.installDate |
|
Device.deviceVersion.value |
|
Device.conformsTo |
|
Device.conformsTo.category |
|
Device.conformsTo.specification |
|
Device.conformsTo.version |
|
Device.property.value[x] |
|
Device.mode |
|
Device.cycle |
|
Device.duration |
|
Device.endpoint |
|
Device.gateway |
|
Device.statusReason |
|
Device.distinctIdentifier |
|
Device.deviceName.name |
|
Device.specialization.systemType |
|
Device.version |
|
Device.property.valueQuantity |
|
Device.property.valueCode |
|
Device.patient |
|
See the Full Difference for further information
This analysis is available for R4 as XML or JSON and for R4B as XML or JSON.
Structure
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | TU | DomainResource | Item used in healthcare + Rule: only one Device.name.display SHALL be true when there is more than one Device.name Elements defined in Ancestors: id, meta, implicitRules, language, text, contained, extension, modifierExtension | |
identifier | 0..* | Identifier | Instance identifier | |
definition | 0..1 | CodeableReference(DeviceDefinition) | The reference to the definition for the device Binding: Device Type (Required) | |
udiCarrier | Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string |
deviceIdentifier | Σ | 1..1 | string | Mandatory fixed portion of UDI |
deviceIdentifierSystem | 0..1 | uri | The namespace for the device identifier value | |
issuer | Σ | 1..1 | uri | UDI Issuing Organization |
jurisdiction | 0..1 | uri | Regional UDI authority | |
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String |
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String |
entryType | 0..1 | code | barcode | rfid | manual | card | self-reported | electronic-transmission | unknown Binding: UDI Entry Type (Required) | |
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error Binding: FHIR Device Status (Required) |
availabilityStatus | 0..1 | CodeableConcept | lost | damaged | destroyed | available Binding: FHIR Device Availability Status (Extensible) | |
biologicalSourceEvent | 0..1 | Identifier | An identifier that supports traceability to the event during which material in this product from one or more biological entities was obtained or pooled | |
manufacturer | 0..1 | string | Name of device manufacturer | |
manufactureDate | 0..1 | dateTime | Date when the device was made | |
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
lotNumber | 0..1 | string | Lot number of manufacture | |
serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |
name | C | 0..* | BackboneElement | The name or names of the device as known to the manufacturer and/or patient |
value | Σ | 1..1 | string | The term that names the device |
type | Σ | 1..1 | CodeableConcept | registered-name | user-friendly-name | patient-reported-name Binding: Device Name Type (Extensible) |
display | ?!ΣC | 0..1 | boolean | The preferred device name |
modelNumber | 0..1 | string | The manufacturer's model number for the device | |
partNumber | 0..1 | string | The part number or catalog number of the device | |
category | 0..* | CodeableConcept | Indicates a high-level grouping of the device Binding: FHIR Device Category (Example) | |
type | 0..* | CodeableConcept | The kind or type of device Binding: Device Type (Example) | |
deviceVersion | 0..* | BackboneElement | The actual design of the device or software version running on the device | |
type | 0..1 | CodeableConcept | The type of the device version, e.g. manufacturer, approved, internal Binding: Device Version Type (Example) | |
component | 0..1 | Identifier | The hardware or software module of the device to which the version applies | |
installDate | 0..1 | dateTime | The date the version was installed on the device | |
value | 1..1 | string | The version text | |
conformsTo | 0..* | BackboneElement | Identifies the standards, specifications, or formal guidances for the capabilities supported by the device | |
category | 0..1 | CodeableConcept | Describes the common type of the standard, specification, or formal guidance. communication | performance | measurement Binding: Device Specification Category (Example) | |
specification | 1..1 | CodeableConcept | Identifies the standard, specification, or formal guidance that the device adheres to Binding: Device Specification Type (Example) | |
version | 0..1 | string | Specific form or variant of the standard | |
property | 0..* | BackboneElement | Inherent, essentially fixed, characteristics of the device. e.g., time properties, size, material, etc. | |
type | 1..1 | CodeableConcept | Code that specifies the property being represented Binding: Device Property Type (Example) | |
value[x] | 1..1 | Value of the property | ||
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueAttachment | Attachment | |||
mode | 0..1 | CodeableConcept | The designated condition for performing a task Binding: FHIR Device Operation Mode (Example) | |
cycle | 0..1 | Count | The series of occurrences that repeats during the operation of the device | |
duration | 0..1 | Duration | A measurement of time during the device's operation (e.g., days, hours, mins, etc.) | |
owner | 0..1 | Reference(Organization) | Organization responsible for device | |
contact | 0..* | ContactPoint | Details for human/organization for support | |
location | 0..1 | Reference(Location) | Where the device is found | |
url | 0..1 | uri | Network address to contact device | |
endpoint | 0..* | Reference(Endpoint) | Technical endpoints providing access to electronic services provided by the device | |
gateway | 0..* | CodeableReference(Device) | Linked device acting as a communication/data collector, translator or controller | |
note | 0..* | Annotation | Device notes and comments | |
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device Binding: Device Safety (Example) |
parent | 0..1 | Reference(Device) | The higher level or encompassing device that this device is a logical part of | |
Documentation for this format |
See the Extensions for this resource
XML Template
<Device xmlns="http://hl7.org/fhir"> <!-- from Resource: id, meta, implicitRules, and language --> <!-- from DomainResource: text, contained, extension, and modifierExtension --> <identifier><!-- 0..* Identifier Instance identifier --></identifier> <definition><!-- 0..1 CodeableReference(DeviceDefinition) The reference to the definition for the device --></definition> <udiCarrier> <!-- 0..* Unique Device Identifier (UDI) Barcode string --> <deviceIdentifier value="[string]"/><!-- 1..1 Mandatory fixed portion of UDI --> <deviceIdentifierSystem value="[uri]"/><!-- 0..1 The namespace for the device identifier value --> <issuer value="[uri]"/><!-- 1..1 UDI Issuing Organization --> <jurisdiction value="[uri]"/><!-- 0..1 Regional UDI authority --> <carrierAIDC value="[base64Binary]"/><!-- 0..1 UDI Machine Readable Barcode String --> <carrierHRF value="[string]"/><!-- 0..1 UDI Human Readable Barcode String --> <entryType value="[code]"/><!-- 0..1 barcode | rfid | manual | card | self-reported | electronic-transmission | unknown --> </udiCarrier> <status value="[code]"/><!-- 0..1 active | inactive | entered-in-error --> <availabilityStatus><!-- 0..1 CodeableConcept lost | damaged | destroyed | available --></availabilityStatus> <biologicalSourceEvent><!-- 0..1 Identifier An identifier that supports traceability to the event during which material in this product from one or more biological entities was obtained or pooled --></biologicalSourceEvent> <manufacturer value="[string]"/><!-- 0..1 Name of device manufacturer --> <manufactureDate value="[dateTime]"/><!-- 0..1 Date when the device was made --> <expirationDate value="[dateTime]"/><!-- 0..1 Date and time of expiry of this device (if applicable) --> <lotNumber value="[string]"/><!-- 0..1 Lot number of manufacture --> <serialNumber value="[string]"/><!-- 0..1 Serial number assigned by the manufacturer --> <name> <!-- I 0..* The name or names of the device as known to the manufacturer and/or patient --> <value value="[string]"/><!-- 1..1 The term that names the device --> <type><!-- 1..1 CodeableConcept registered-name | user-friendly-name | patient-reported-name --></type> <display value="[boolean]"/><!-- I 0..1 The preferred device name --> </name> <modelNumber value="[string]"/><!-- 0..1 The manufacturer's model number for the device --> <partNumber value="[string]"/><!-- 0..1 The part number or catalog number of the device --> <category><!-- 0..* CodeableConcept Indicates a high-level grouping of the device --></category> <type><!-- 0..* CodeableConcept The kind or type of device --></type> <deviceVersion> <!-- 0..* The actual design of the device or software version running on the device --> <type><!-- 0..1 CodeableConcept The type of the device version, e.g. manufacturer, approved, internal --></type> <component><!-- 0..1 Identifier The hardware or software module of the device to which the version applies --></component> <installDate value="[dateTime]"/><!-- 0..1 The date the version was installed on the device --> <value value="[string]"/><!-- 1..1 The version text --> </deviceVersion> <conformsTo> <!-- 0..* Identifies the standards, specifications, or formal guidances for the capabilities supported by the device --> <category><!-- 0..1 CodeableConcept Describes the common type of the standard, specification, or formal guidance. communication | performance | measurement --></category> <specification><!-- 1..1 CodeableConcept Identifies the standard, specification, or formal guidance that the device adheres to --></specification> <version value="[string]"/><!-- 0..1 Specific form or variant of the standard --> </conformsTo> <property> <!-- 0..* Inherent, essentially fixed, characteristics of the device. e.g., time properties, size, material, etc. --> <type><!-- 1..1 CodeableConcept Code that specifies the property being represented --></type> <value[x]><!-- 1..1 Quantity|CodeableConcept|string|boolean|integer|Range| Attachment Value of the property --></value[x]> </property> <mode><!-- 0..1 CodeableConcept The designated condition for performing a task --></mode> <cycle><!-- 0..1 Count The series of occurrences that repeats during the operation of the device --></cycle> <duration><!-- 0..1 Duration A measurement of time during the device's operation (e.g., days, hours, mins, etc.) --></duration> <owner><!-- 0..1 Reference(Organization) Organization responsible for device --></owner> <contact><!-- 0..* ContactPoint Details for human/organization for support --></contact> <location><!-- 0..1 Reference(Location) Where the device is found --></location> <url value="[uri]"/><!-- 0..1 Network address to contact device --> <endpoint><!-- 0..* Reference(Endpoint) Technical endpoints providing access to electronic services provided by the device --></endpoint> <gateway><!-- 0..* CodeableReference(Device) Linked device acting as a communication/data collector, translator or controller --></gateway> <note><!-- 0..* Annotation Device notes and comments --></note> <safety><!-- 0..* CodeableConcept Safety Characteristics of Device --></safety> <parent><!-- 0..1 Reference(Device) The higher level or encompassing device that this device is a logical part of --></parent> </Device>
JSON Template
{ "resourceType" : "Device", // from Resource: id, meta, implicitRules, and language // from DomainResource: text, contained, extension, and modifierExtension "identifier" : [{ Identifier }], // Instance identifier "definition" : { CodeableReference(DeviceDefinition) }, // The reference to the definition for the device "udiCarrier" : [{ // Unique Device Identifier (UDI) Barcode string "deviceIdentifier" : "<string>", // R! Mandatory fixed portion of UDI "deviceIdentifierSystem" : "<uri>", // The namespace for the device identifier value "issuer" : "<uri>", // R! UDI Issuing Organization "jurisdiction" : "<uri>", // Regional UDI authority "carrierAIDC" : "<base64Binary>", // UDI Machine Readable Barcode String "carrierHRF" : "<string>", // UDI Human Readable Barcode String "entryType" : "<code>" // barcode | rfid | manual | card | self-reported | electronic-transmission | unknown }], "status" : "<code>", // active | inactive | entered-in-error "availabilityStatus" : { CodeableConcept }, // lost | damaged | destroyed | available "biologicalSourceEvent" : { Identifier }, // An identifier that supports traceability to the event during which material in this product from one or more biological entities was obtained or pooled "manufacturer" : "<string>", // Name of device manufacturer "manufactureDate" : "<dateTime>", // Date when the device was made "expirationDate" : "<dateTime>", // Date and time of expiry of this device (if applicable) "lotNumber" : "<string>", // Lot number of manufacture "serialNumber" : "<string>", // Serial number assigned by the manufacturer "name" : [{ // I The name or names of the device as known to the manufacturer and/or patient "value" : "<string>", // R! The term that names the device "type" : { CodeableConcept }, // R! registered-name | user-friendly-name | patient-reported-name "display" : <boolean> // I The preferred device name }], "modelNumber" : "<string>", // The manufacturer's model number for the device "partNumber" : "<string>", // The part number or catalog number of the device "category" : [{ CodeableConcept }], // Indicates a high-level grouping of the device "type" : [{ CodeableConcept }], // The kind or type of device "deviceVersion" : [{ // The actual design of the device or software version running on the device "type" : { CodeableConcept }, // The type of the device version, e.g. manufacturer, approved, internal "component" : { Identifier }, // The hardware or software module of the device to which the version applies "installDate" : "<dateTime>", // The date the version was installed on the device "value" : "<string>" // R! The version text }], "conformsTo" : [{ // Identifies the standards, specifications, or formal guidances for the capabilities supported by the device "category" : { CodeableConcept }, // Describes the common type of the standard, specification, or formal guidance. communication | performance | measurement "specification" : { CodeableConcept }, // R! Identifies the standard, specification, or formal guidance that the device adheres to "version" : "<string>" // Specific form or variant of the standard }], "property" : [{ // Inherent, essentially fixed, characteristics of the device. e.g., time properties, size, material, etc. "type" : { CodeableConcept }, // R! Code that specifies the property being represented // value[x]: Value of the property. One of these 7: "valueQuantity" : { Quantity }, "valueCodeableConcept" : { CodeableConcept }, "valueString" : "<string>", "valueBoolean" : <boolean>, "valueInteger" : <integer>, "valueRange" : { Range }, "valueAttachment" : { Attachment } }], "mode" : { CodeableConcept }, // The designated condition for performing a task "cycle" : { Count }, // The series of occurrences that repeats during the operation of the device "duration" : { Duration }, // A measurement of time during the device's operation (e.g., days, hours, mins, etc.) "owner" : { Reference(Organization) }, // Organization responsible for device "contact" : [{ ContactPoint }], // Details for human/organization for support "location" : { Reference(Location) }, // Where the device is found "url" : "<uri>", // Network address to contact device "endpoint" : [{ Reference(Endpoint) }], // Technical endpoints providing access to electronic services provided by the device "gateway" : [{ CodeableReference(Device) }], // Linked device acting as a communication/data collector, translator or controller "note" : [{ Annotation }], // Device notes and comments "safety" : [{ CodeableConcept }], // Safety Characteristics of Device "parent" : { Reference(Device) } // The higher level or encompassing device that this device is a logical part of }
Turtle Template
@prefix fhir: <http://hl7.org/fhir/> . [ a fhir:Device; fhir:nodeRole fhir:treeRoot; # if this is the parser root # from Resource: .id, .meta, .implicitRules, and .language # from DomainResource: .text, .contained, .extension, and .modifierExtension fhir:identifier ( [ Identifier ] ... ) ; # 0..* Instance identifier fhir:definition [ CodeableReference(DeviceDefinition) ] ; # 0..1 The reference to the definition for the device fhir:udiCarrier ( [ # 0..* Unique Device Identifier (UDI) Barcode string fhir:deviceIdentifier [ string ] ; # 1..1 Mandatory fixed portion of UDI fhir:deviceIdentifierSystem [ uri ] ; # 0..1 The namespace for the device identifier value fhir:issuer [ uri ] ; # 1..1 UDI Issuing Organization fhir:jurisdiction [ uri ] ; # 0..1 Regional UDI authority fhir:carrierAIDC [ base64Binary ] ; # 0..1 UDI Machine Readable Barcode String fhir:carrierHRF [ string ] ; # 0..1 UDI Human Readable Barcode String fhir:entryType [ code ] ; # 0..1 barcode | rfid | manual | card | self-reported | electronic-transmission | unknown ] ... ) ; fhir:status [ code ] ; # 0..1 active | inactive | entered-in-error fhir:availabilityStatus [ CodeableConcept ] ; # 0..1 lost | damaged | destroyed | available fhir:biologicalSourceEvent [ Identifier ] ; # 0..1 An identifier that supports traceability to the event during which material in this product from one or more biological entities was obtained or pooled fhir:manufacturer [ string ] ; # 0..1 Name of device manufacturer fhir:manufactureDate [ dateTime ] ; # 0..1 Date when the device was made fhir:expirationDate [ dateTime ] ; # 0..1 Date and time of expiry of this device (if applicable) fhir:lotNumber [ string ] ; # 0..1 Lot number of manufacture fhir:serialNumber [ string ] ; # 0..1 Serial number assigned by the manufacturer fhir:name ( [ # 0..* I The name or names of the device as known to the manufacturer and/or patient fhir:value [ string ] ; # 1..1 The term that names the device fhir:type [ CodeableConcept ] ; # 1..1 registered-name | user-friendly-name | patient-reported-name fhir:display [ boolean ] ; # 0..1 I The preferred device name ] ... ) ; fhir:modelNumber [ string ] ; # 0..1 The manufacturer's model number for the device fhir:partNumber [ string ] ; # 0..1 The part number or catalog number of the device fhir:category ( [ CodeableConcept ] ... ) ; # 0..* Indicates a high-level grouping of the device fhir:type ( [ CodeableConcept ] ... ) ; # 0..* The kind or type of device fhir:deviceVersion ( [ # 0..* The actual design of the device or software version running on the device fhir:type [ CodeableConcept ] ; # 0..1 The type of the device version, e.g. manufacturer, approved, internal fhir:component [ Identifier ] ; # 0..1 The hardware or software module of the device to which the version applies fhir:installDate [ dateTime ] ; # 0..1 The date the version was installed on the device fhir:value [ string ] ; # 1..1 The version text ] ... ) ; fhir:conformsTo ( [ # 0..* Identifies the standards, specifications, or formal guidances for the capabilities supported by the device fhir:category [ CodeableConcept ] ; # 0..1 Describes the common type of the standard, specification, or formal guidance. communication | performance | measurement fhir:specification [ CodeableConcept ] ; # 1..1 Identifies the standard, specification, or formal guidance that the device adheres to fhir:version [ string ] ; # 0..1 Specific form or variant of the standard ] ... ) ; fhir:property ( [ # 0..* Inherent, essentially fixed, characteristics of the device. e.g., time properties, size, material, etc. fhir:type [ CodeableConcept ] ; # 1..1 Code that specifies the property being represented # value[x] : 1..1 Value of the property. One of these 7 fhir:value [ a fhir:Quantity ; Quantity ] fhir:value [ a fhir:CodeableConcept ; CodeableConcept ] fhir:value [ a fhir:string ; string ] fhir:value [ a fhir:boolean ; boolean ] fhir:value [ a fhir:integer ; integer ] fhir:value [ a fhir:Range ; Range ] fhir:value [ a fhir:Attachment ; Attachment ] ] ... ) ; fhir:mode [ CodeableConcept ] ; # 0..1 The designated condition for performing a task fhir:cycle [ Count ] ; # 0..1 The series of occurrences that repeats during the operation of the device fhir:duration [ Duration ] ; # 0..1 A measurement of time during the device's operation (e.g., days, hours, mins, etc.) fhir:owner [ Reference(Organization) ] ; # 0..1 Organization responsible for device fhir:contact ( [ ContactPoint ] ... ) ; # 0..* Details for human/organization for support fhir:location [ Reference(Location) ] ; # 0..1 Where the device is found fhir:url [ uri ] ; # 0..1 Network address to contact device fhir:endpoint ( [ Reference(Endpoint) ] ... ) ; # 0..* Technical endpoints providing access to electronic services provided by the device fhir:gateway ( [ CodeableReference(Device) ] ... ) ; # 0..* Linked device acting as a communication/data collector, translator or controller fhir:note ( [ Annotation ] ... ) ; # 0..* Device notes and comments fhir:safety ( [ CodeableConcept ] ... ) ; # 0..* Safety Characteristics of Device fhir:parent [ Reference(Device) ] ; # 0..1 The higher level or encompassing device that this device is a logical part of ]
Changes from both R4 and R4B
Device | |
Device.definition |
|
Device.udiCarrier.deviceIdentifier |
|
Device.udiCarrier.deviceIdentifierSystem |
|
Device.udiCarrier.issuer |
|
Device.udiCarrier.entryType |
|
Device.status |
|
Device.availabilityStatus |
|
Device.biologicalSourceEvent |
|
Device.name |
|
Device.name.value |
|
Device.name.type |
|
Device.name.display |
|
Device.category |
|
Device.type |
|
Device.deviceVersion |
|
Device.deviceVersion.type |
|
Device.deviceVersion.component |
|
Device.deviceVersion.installDate |
|
Device.deviceVersion.value |
|
Device.conformsTo |
|
Device.conformsTo.category |
|
Device.conformsTo.specification |
|
Device.conformsTo.version |
|
Device.property.value[x] |
|
Device.mode |
|
Device.cycle |
|
Device.duration |
|
Device.endpoint |
|
Device.gateway |
|
Device.statusReason |
|
Device.distinctIdentifier |
|
Device.deviceName.name |
|
Device.specialization.systemType |
|
Device.version |
|
Device.property.valueQuantity |
|
Device.property.valueCode |
|
Device.patient |
|
See the Full Difference for further information
This analysis is available for R4 as XML or JSON and for R4B as XML or JSON.
Additional definitions: Master Definition XML + JSON, XML Schema/Schematron + JSON Schema, ShEx (for Turtle) + see the extensions, the spreadsheet version & the dependency analysis
Path | ValueSet | Type | Documentation |
---|---|---|---|
Device.definition | DeviceType | Required | Codes used to identify medical devices. Includes concepts from SNOMED CT (http://www.snomed.org/) where concept is-a 49062001 (Device) and is provided as a suggestive example. |
Device.udiCarrier.entryType | UDIEntryType | Required | Codes to identify how UDI data was entered. |
Device.status | FHIRDeviceStatus | Required | The status of the Device record. |
Device.availabilityStatus | FHIRDeviceAvailabilityStatus | Extensible | The availability status of the device. |
Device.name.type | DeviceNameType | Extensible | The type of name the device is referred by. |
Device.category | FHIRDeviceCategory | Example | The association state of the device. |
Device.type | DeviceType | Example | Codes used to identify medical devices. Includes concepts from SNOMED CT (http://www.snomed.org/) where concept is-a 49062001 (Device) and is provided as a suggestive example. |
Device.deviceVersion.type | DeviceVersionType | Example | Describes the type of version |
Device.conformsTo.category | DeviceSpecificationCategory (a valid code from FHIR Device Specialization Category) | Example | The kind of standards used by the device. |
Device.conformsTo.specification | DeviceSpecificationType | Example | The type or specification of a standard that devices can adhere to |
Device.property.type | DeviceType | Example | Codes used to identify medical devices. Includes concepts from SNOMED CT (http://www.snomed.org/) where concept is-a 49062001 (Device) and is provided as a suggestive example. |
Device.mode | FHIRDeviceOperationMode | Example | The operation mode of the device. |
Device.safety | DeviceSafety | Example | Codes used to identify medical devices safety characteristics. These codes are taken from the NCI Thesaurus and are provided here as a suggestive example. |
UniqueKey | Level | Location | Description | Expression |
dev-1 | Rule | (base) | only one Device.name.display SHALL be true when there is more than one Device.name | name.where(display=true).count() <= 1 |
Nearly all devices are assigned a string of characters to represent one or more identifiers or codes, which are usually printed or affixed to the device using either barcodes or RFIDs. The identifier or code can come from the manufacturer (for example, a 'serial number', 'reference number', or 'catalog number'), various institution and registries. Any of these identifiers or codes assigned to the device can and should be recorded in the device resource. However, there can there can be confusion where to represent them in the resource because codes and identifiers are represented in FHIR as semantically distinct elements and because organizations may conflate the term 'code' for an identifier or 'identifier' for a code in their names.
The identifier
element is only intended for use when it's an actual identifier for a specific instance of a device. That would mean that each device would have a separate serial number and would be represented using this element - devices without serial numbers (for example, a box of syringes) would not. Concepts such as a reference number or catalog number or GTIN describe a code which represents a kind of device and are conveyed using the type
element. Some sources of standard codes for devices and translations within type
are listed below:
For systems that do have a system URI for device types (indicating the model number or part number), they can and should appear as codings in Device.type
.
The International Medical Device Regulators Forum IMDRF UDI Working Group published UDI System for Medical Devices (Version 2.0) , the base specification for Unique Device Identifiers (UDI). The United States Food and Drug Administration has produced an implementation guide for Unique Device Identifiers (UDI) which implements the IMDRF specification and other jurisdictions may produce similar IMDRF implementation guides as well. The full UDI string that represents the barcode as printed on the packaging of the device or Automatic Identification and Data Capture (AIDC) representation is called the "UDI carrier". The UDI has 2 components*:
*non-UDI elements may also appear within the UDI carrier. **a "GTIN" (sometimes also called an EAN number) is a code developed by GS1 for the kind of device not an identifier for the device. A GTIN may appear on its own or it may appear in a UDI string as the DI component.
The DI of the UDI may be stored in a jurisdictional repository and used as the primary key to access other device information. For example, in the United States, the DI of the UDI is submitted in a device record to the Global Unique Device Identification Database (GUDID) . The UDI may identify an instance of a device uniquely (when the PI includes a serial number), or it may just identify the type of the device. The UDI is parsed into its constituent parts (DI, PI and other elements) by parsing rules developed by each Issuing Agency standard. Where the device has an assigned UDI, the other details carried in the resource (e.g., lot, expiration date, etc.) SHALL be consistent with the information encoded in the UDI string or registered in the local repository.
Best practice guidelines for transmitting UDI data using the Device resource dictate transmitting both the UDI Carrier and all components found within the UDI as described in Device UDI Mapping. Several examples are provided for further guidance.
Devices.status is about the record, while operationalStatus and associationStatus are about other aspects of the device.
Search parameters for this resource. See also the full list of search parameters for this resource, and check the Extensions registry for search parameters on extensions related to this resource. The common parameters also apply. See Searching for more information about searching in REST, messaging, and services.
Name | Type | Description | Expression | In Common |
biological-source-event | token | The biological source for the device | Device.biologicalSourceEvent | |
code | token | The definition / type of the device (code) | Device.definition.concept | |
code-value-concept | composite | Code and value parameter pair | On Device: specification: specification.ofType(CodeableConcept) version: version.ofType(string) |
|
definition | reference | The definition / type of the device | Device.definition.reference | |
device-name | string | A server defined search that may match any of the string fields in Device.name or Device.type. | Device.name.value | Device.type.coding.display | Device.type.text | |
expiration-date | date | The expiration date of the device | Device.expirationDate | |
identifier | token | Instance id from manufacturer, owner, and others | Device.identifier | |
location | reference | A location, where the resource is found | Device.location (Location) |
|
lot-number | string | The lot number of the device | Device.lotNumber | |
manufacture-date | date | The manufacture date of the device | Device.manufactureDate | |
manufacturer | string | The manufacturer of the device | Device.manufacturer | |
model | string | The model of the device | Device.modelNumber | |
organization | reference | The organization responsible for the device | Device.owner (Organization) |
|
parent | reference | The parent device | Device.parent (Device) |
|
serial-number | string | The serial number of the device | Device.serialNumber | Device.identifier.where(type='SNO') | |
specification | token | The standards, specifications, or formal guidances. | Device.conformsTo.specification | |
specification-version | composite | A composite of both specification and version | On Device.conformsTo: specification: specification version: version |
|
status | token | active | inactive | entered-in-error | unknown | Device.status | |
type | token | The type of the device | Device.type | |
udi-carrier-hrf | string | UDI Barcode (RFID or other technology) string in HRF format. |
Device.udiCarrier.carrierHRF | |
udi-di | string | The udi Device Identifier (DI) | Device.udiCarrier.deviceIdentifier | |
url | uri | Network address to contact device | Device.url | |
version | string | The specific version of the device | Device.deviceVersion.value | |
version-type | composite | Value and type of version | On Device.deviceVersion: type: type value: value |