http://hl7.org/fhir/SearchParameter/Specimen-accession
10.8.16 accession Parameter accession
:token
The accession number associated with the specimen
Resource Specimen Expression Specimen.accessionIdentifier
Processing Mode Normal Multiples multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/Specimen-bodysite
10.8.17 bodysite Parameter bodysite
:reference
Reference to a resource (by instance)
Resource Specimen Expression Specimen.collection.bodySite.reference
Processing Mode Normal Target Resources BodyStructure Multiples multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/Specimen-collected
10.8.18 collected Parameter collected
:date
The date the specimen was collected
Resource Specimen Expression Specimen.collection.collected.ofType(dateTime) | Specimen.collection.collected.ofType(Period)
Processing Mode Normal Multiples multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true Comparators Allowed: eq, ne, gt, ge, lt, le, sa, eb, ap
http://hl7.org/fhir/SearchParameter/Specimen-collector
10.8.19 collector Parameter collector
:reference
Who collected the specimen
Resource Specimen Expression Specimen.collection.collector
Processing Mode Normal Target Resources RelatedPerson , PractitionerRole , Practitioner , Patient Multiples multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/Specimen-container-device
10.8.20 container-device Parameter container-device
:reference
The unique identifier associated with the specimen container
Resource Specimen Expression Specimen.container.device.where(resolve() is Device)
Processing Mode Normal Target Resources Device Multiples multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/clinical-identifier
This search parameter is part of the common search parameter clinical-identifier 10.8.21 identifier Parameter identifier
:token
Specimen : The unique identifier associated with the specimen
Resource Specimen Expression Specimen.identifier
Processing Mode Normal Multiples multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/Specimen-parent
10.8.22 parent Parameter parent
:reference
The parent of the specimen
Resource Specimen Expression Specimen.parent
Processing Mode Normal Target Resources Specimen Multiples multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/clinical-patient
This search parameter is part of the common search parameter clinical-patient 10.8.23 patient Parameter patient
:reference
Specimen : The patient the specimen comes from
Resource Specimen Expression Specimen.subject.where(resolve() is Patient)
Processing Mode Normal Target Resources Patient Multiples multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/Specimen-procedure
10.8.24 procedure Parameter procedure
:reference
The procedure that collected the specimen
Resource Specimen Expression Specimen.collection.procedure
Processing Mode Normal Target Resources Procedure Multiples multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/Specimen-status
10.8.25 status Parameter status
:token
available | unavailable | unsatisfactory | entered-in-error
Resource Specimen Expression Specimen.status
Processing Mode Normal Multiples multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/Specimen-subject
10.8.26 subject Parameter subject
:reference
The subject of the specimen
Resource Specimen Expression Specimen.subject
Processing Mode Normal Target Resources Device , Group , BiologicallyDerivedProduct , Substance , Location , Patient Multiples multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
http://hl7.org/fhir/SearchParameter/clinical-type
This search parameter is part of the common search parameter clinical-type 10.8.27 type Parameter type
:token
Resource Specimen Expression Specimen.type