Release 5 Ballot

This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Imaging Integration Work GroupMaturity Level: N/AStandards Status: InformativeSecurity Category: Patient Compartments: Patient

Search Parameter Registry for the imagingstudy resource

Search parameter list for this resource. The common parameters also apply. See Searching for more information about searching in REST, messaging, and services.

http://hl7.org/fhir/SearchParameter/ImagingStudy-basedon

Parameter basedon:reference

The order for the image, such as Accession Number associated with a ServiceRequest

ResourceImagingStudy
ExpressionImagingStudy.basedOn
Target ResourcesAppointment, AppointmentResponse, CarePlan, Task, ServiceRequest
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-bodysite

Parameter bodysite:token

The body site studied

ResourceImagingStudy
ExpressionImagingStudy.series.bodySite.concept
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-dicom-class

Parameter dicom-class:token

The type of the instance

ResourceImagingStudy
ExpressionImagingStudy.series.instance.sopClass
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-encounter

Parameter encounter:reference

The context of the study

ResourceImagingStudy
ExpressionImagingStudy.encounter
Target ResourcesEncounter
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-endpoint

Parameter endpoint:reference

The endpoint for the study or series

ResourceImagingStudy
ExpressionImagingStudy.endpoint | ImagingStudy.series.endpoint
Target ResourcesEndpoint
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/build/SearchParameter/ImagingStudy-identifier

Parameter identifier:token

Identifiers for the Study, such as DICOM Study Instance UID

Resources
ExpressionImagingStudy.identifier
UsageNormal
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-instance

Parameter instance:token

SOP Instance UID for an instance

ResourceImagingStudy
ExpressionImagingStudy.series.instance.uid
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-interpreter

Parameter interpreter:reference

Who interpreted the images

ResourceImagingStudy
ExpressionImagingStudy.interpreter
Target ResourcesPractitioner, PractitionerRole
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-modality

Parameter modality:token

The modality of the series

ResourceImagingStudy
ExpressionImagingStudy.series.modality
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/build/SearchParameter/ImagingStudy-patient

Parameter patient:reference

Who the study is about

Resources
ExpressionImagingStudy.subject.where(resolve() is Patient)
UsageNormal
Target ResourcesPatient
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-performer

Parameter performer:reference

The person who performed the study

ResourceImagingStudy
ExpressionImagingStudy.series.performer.actor
Target ResourcesPractitioner, Organization, CareTeam, Device, Patient, HealthcareService, PractitionerRole, RelatedPerson
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-reason

Parameter reason:token

The reason for the study

ResourceImagingStudy
Expression(none)
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-referrer

Parameter referrer:reference

The referring physician

ResourceImagingStudy
ExpressionImagingStudy.referrer
Target ResourcesPractitioner, PractitionerRole
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-series

Parameter series:token

DICOM Series Instance UID for a series

ResourceImagingStudy
ExpressionImagingStudy.series.uid
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-started

Parameter started:date

When the study was started

ResourceImagingStudy
ExpressionImagingStudy.started
MultiplesThe parameter cannot repeat or have multiple values
ComparatorsAllowed: eq, ne, gt, ge, lt, le, sa, eb, ap
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-status

Parameter status:token

The status of the study

ResourceImagingStudy
ExpressionImagingStudy.status
MultiplesThe parameter cannot repeat or have multiple values
 
http://hl7.org/fhir/SearchParameter/ImagingStudy-subject

Parameter subject:reference

Who the study is about

ResourceImagingStudy
ExpressionImagingStudy.subject
Target ResourcesGroup, Device, Patient
MultiplesThe parameter cannot repeat or have multiple values