This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
(No assigned work group) | Maturity Level: 1 | Informative | Use Context: Any |
Definitions for the bmi Profile.
Observation | |
Element Id | Observation |
Definition | This profile defines how to represent Body Mass Index (BMI) observations in FHIR using a standard LOINC code and UCUM units of measure. |
Control | 0..* |
Alternate Names | Vital Signs, Measurement, Results, Tests |
Comments | Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc. |
Invariants | Defined on this element dom-1: If the resource is contained in another resource, it SHALL NOT contain any narrative (xpath: not(parent::f:contained and f:text)) dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (xpath: not(parent::f:contained and f:contained)) dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (xpath: not(exists(for $contained in f:contained return $contained[not(parent::*/descendant::f:reference/@value=concat('#', $contained/*/id/@value) or descendant::f:reference[@value='#'])]))) dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (xpath: not(exists(f:contained/*/f:meta/f:versionId)) and not(exists(f:contained/*/f:meta/f:lastUpdated))) obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (xpath: not(exists(f:dataAbsentReason)) or (not(exists(*[starts-with(local-name(.), 'value')])))) obs-7: If Observation.code is the same as a Observation.component.code then the value element associated with the code SHALL NOT be present (xpath: not(f:*[starts-with(local-name(.), 'value')] and (for $coding in f:code/f:coding return f:component/f:code/f:coding[f:code/@value=$coding/f:code/@value] [f:system/@value=$coding/f:system/@value]))) vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. (xpath: f:component or f:memberOF or f:*[starts-with(local-name(.), 'value')] or f:dataAbsentReason) |
Observation.id | |
Element Id | Observation.id |
Definition | The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. |
Control | 0..1 |
Type | id |
Comments | The only time that a resource does not have an id is when it is being submitted to the server using a create operation. |
Observation.meta | |
Element Id | Observation.meta |
Definition | The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource. |
Control | 0..1 |
Type | Meta |
Observation.implicitRules | |
Element Id | Observation.implicitRules |
Definition | A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc. |
Control | 0..1 |
Type | uri |
Is Modifier | true (Reason: This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation) |
Comments | Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc. |
Observation.language | |
Element Id | Observation.language |
Definition | The base language in which the resource is written. |
Control | 0..1 |
Terminology Binding | A human language. The codes SHALL be taken from Common Languages; other codes may be used where these codes are not suitable |
Type | code |
Comments | Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). |
Observation.text | |
Element Id | Observation.text |
Definition | A human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. |
Control | 0..1 This element is affected by the following invariants: dom-1 |
Type | Narrative |
Alternate Names | narrative, html, xhtml, display |
Comments | Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded in formation is added later. |
Observation.contained | |
Element Id | Observation.contained |
Definition | These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. |
Control | 0..* |
Type | Resource |
Alternate Names | inline resources, anonymous resources, contained resources |
Comments | This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. |
Observation.extension | |
Element Id | Observation.extension |
Definition | May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Observation.modifierExtension | |
Element Id | Observation.modifierExtension |
Definition | May be used to represent additional information that is not part of the basic definition of the resource, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. |
Control | 0..* |
Type | Extension |
Is Modifier | true (Reason: Not known why this is labelled a modifier) |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Observation.identifier | |
Element Id | Observation.identifier |
Definition | A unique identifier assigned to this observation. |
Control | 0..* |
Type | Identifier |
Requirements | Allows observations to be distinguished and referenced. |
Observation.basedOn | |
Element Id | Observation.basedOn |
Definition | A plan, proposal or order that is fulfilled in whole or in part by this event. |
Control | 0..* |
Type | Reference(CarePlan) |
Requirements | Allows tracing of authorization for the event and tracking whether proposals/recommendations were acted upon. |
Alternate Names | Fulfills |
Observation.partOf | |
Element Id | Observation.partOf |
Definition | A larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure. |
Control | 0..* |
Type | Reference(MedicationAdministration) |
Alternate Names | Container |
Comments | To link an Observation to an Encounter use |
Observation.status | |
Element Id | Observation.status |
Definition | The status of the result value. |
Control | 1..1 |
Terminology Binding | null The codes SHALL be taken from ObservationStatus |
Type | code |
Is Modifier | true (Reason: This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid) |
Must Support | true |
Requirements | Need to track the status of individual results. Some results are finalized before the whole report is finalized. |
Comments | This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid. |
Observation.category | |
Element Id | Observation.category |
Definition | A code that classifies the general type of observation being made. |
Control | 1..* |
Terminology Binding | Codes for high level observation categories. The codes SHOULD be taken from Observation Category Codes |
Type | CodeableConcept |
Must Support | true |
Requirements | Used for filtering what observations are retrieved and displayed. |
Comments | In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set. |
Slicing | This element introduces a set of slices. The slicing rules are:
|
Observation.category(VSCat) | |
Element Id | Observation.category:vscat |
Definition | A code that classifies the general type of observation being made. |
Control | 1..1 |
Terminology Binding | Codes for high level observation categories. The codes SHOULD be taken from Observation Category Codes |
Type | CodeableConcept |
Must Support | true |
Requirements | Used for filtering what observations are retrieved and displayed. |
Comments | In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set. |
Observation.category.id | |
Element Id | Observation.category:vscat.id |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
Observation.category.extension | |
Element Id | Observation.category:vscat.extension |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Slicing | This element introduces a set of slices. The slicing rules are:
|
Observation.category.coding | |
Element Id | Observation.category:vscat.coding |
Definition | A reference to a code defined by a terminology system. |
Control | 1..* |
Type | Coding |
Must Support | true |
Requirements | Allows for translations and alternate encodings within a code system. Also supports communication of the same instance to systems requiring different encodings. |
Comments | Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. |
Observation.category.coding.id | |
Element Id | Observation.category:vscat.coding.id |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
Observation.category.coding.extension | |
Element Id | Observation.category:vscat.coding.extension |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Slicing | This element introduces a set of slices. The slicing rules are:
|
Observation.category.coding.system | |
Element Id | Observation.category:vscat.coding.system |
Definition | The identification of the code system that defines the meaning of the symbol in the code. |
Control | 1..1 |
Type | uri |
Must Support | true |
Requirements | Need to be unambiguous about the source of the definition of the symbol. |
Comments | The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. |
Fixed Value | http://hl7.org/fhir/observation-category |
Observation.category.coding.version | |
Element Id | Observation.category:vscat.coding.version |
Definition | The version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. |
Control | 0..1 |
Type | string |
Comments | Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. |
Observation.category.coding.code | |
Element Id | Observation.category:vscat.coding.code |
Definition | A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). |
Control | 1..1 |
Type | code |
Must Support | true |
Requirements | Need to refer to a particular code in the system. |
Fixed Value | vital-signs |
Observation.category.coding.display | |
Element Id | Observation.category:vscat.coding.display |
Definition | A representation of the meaning of the code in the system, following the rules of the system. |
Control | 0..1 |
Type | string |
Requirements | Need to be able to carry a human-readable meaning of the code for readers that do not know the system. |
Observation.category.coding.userSelected | |
Element Id | Observation.category:vscat.coding.userSelected |
Definition | Indicates that this coding was chosen by a user directly - i.e. off a pick list of available items (codes or displays). |
Control | 0..1 |
Type | boolean |
Requirements | This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. |
Comments | Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. |
Observation.category.text | |
Element Id | Observation.category:vscat.text |
Definition | A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. |
Control | 0..1 |
Type | string |
Requirements | The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. |
Comments | Very often the text is the same as a displayName of one of the codings. |
Observation.code | |
Element Id | Observation.code |
Definition | Body Mass Index (BMI). |
Control | 1..1 |
Terminology Binding | This identifies the vital sign result type. The codes SHALL be taken from Vital Signs; other codes may be used where these codes are not suitable |
Type | CodeableConcept |
Must Support | true |
Requirements |
|
Alternate Names | Name, Test |
Comments | additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system. |
Observation.code.id | |
Element Id | Observation.code.id |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
Observation.code.extension | |
Element Id | Observation.code.extension |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Slicing | This element introduces a set of slices. The slicing rules are:
|
Observation.code.coding | |
Element Id | Observation.code.coding |
Definition | A reference to a code defined by a terminology system. |
Control | 0..* |
Type | Coding |
Requirements | Allows for translations and alternate encodings within a code system. Also supports communication of the same instance to systems requiring different encodings. |
Comments | Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. |
Slicing | This element introduces a set of slices. The slicing rules are:
|
Observation.code.coding(BMICode) | |
Element Id | Observation.code.coding:bmicode |
Definition | A reference to a code defined by a terminology system. |
Control | 1..1 |
Type | Coding |
Requirements | Allows for translations and alternate encodings within a code system. Also supports communication of the same instance to systems requiring different encodings. |
Comments | Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. |
Observation.code.coding.id | |
Element Id | Observation.code.coding:bmicode.id |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
Observation.code.coding.extension | |
Element Id | Observation.code.coding:bmicode.extension |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Slicing | This element introduces a set of slices. The slicing rules are:
|
Observation.code.coding.system | |
Element Id | Observation.code.coding:bmicode.system |
Definition | The identification of the code system that defines the meaning of the symbol in the code. |
Control | 1..1 |
Type | uri |
Requirements | Need to be unambiguous about the source of the definition of the symbol. |
Comments | The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. |
Fixed Value | http://loinc.org |
Observation.code.coding.version | |
Element Id | Observation.code.coding:bmicode.version |
Definition | The version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. |
Control | 0..1 |
Type | string |
Comments | Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. |
Observation.code.coding.code | |
Element Id | Observation.code.coding:bmicode.code |
Definition | A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). |
Control | 1..1 |
Type | code |
Requirements | Need to refer to a particular code in the system. |
Fixed Value | 39156-5 |
Observation.code.coding.display | |
Element Id | Observation.code.coding:bmicode.display |
Definition | A representation of the meaning of the code in the system, following the rules of the system. |
Control | 0..1 |
Type | string |
Requirements | Need to be able to carry a human-readable meaning of the code for readers that do not know the system. |
Observation.code.coding.userSelected | |
Element Id | Observation.code.coding:bmicode.userSelected |
Definition | Indicates that this coding was chosen by a user directly - i.e. off a pick list of available items (codes or displays). |
Control | 0..1 |
Type | boolean |
Requirements | This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. |
Comments | Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. |
Observation.code.text | |
Element Id | Observation.code.text |
Definition | A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. |
Control | 0..1 |
Type | string |
Requirements | The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. |
Comments | Very often the text is the same as a displayName of one of the codings. |
Observation.subject | |
Element Id | Observation.subject |
Definition | The patient, or group of patients, location, or device whose characteristics (direct or indirect) are described by the observation and into whose record the observation is placed. Comments: Indirect characteristics may be those of a specimen, fetus, donor, other observer (for example a relative or EMT), or any observation made about the subject. |
Control | 1..1 |
Type | Reference(Patient) |
Must Support | true |
Requirements | Observations have no value if you don't know who or what they're about. |
Comments | One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated If theactual focus of the observation is different than the subject, the |
Observation.focus | |
Element Id | Observation.focus |
Definition | The actual focus of an observation when it is not the patient of record. The focus is point of attention when the observation representing something or someone associated with the patient. It could be a spouse or parent, a fetus or donor. The focus of an observation could be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus. |
Control | 0..1 |
Type | Reference(Resource) |
Comments | Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use |
Observation.context | |
Element Id | Observation.context |
Definition | The healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made. |
Control | 0..1 |
Type | Reference(Encounter) |
Requirements | For some observations it may be important to know the link between an observation and a particular encounter. |
Alternate Names | Encounter |
Comments | This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter or episode but still be tied to the context of the encounter or episode (e.g. pre-admission laboratory tests). |
Observation.effective[x] | |
Element Id | Observation.effective[x] |
Definition | Often just a dateTime for Vital Signs. |
Control | 1..1 |
Type | Choice of: dateTime, Period |
[x] Note | See Choice of Data Types for further information about how to use [x] |
Must Support | true |
Requirements | Knowing when an observation was deemed true is important to its relevance as well as determining trends. |
Alternate Names | Occurrence |
Comments | At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events. |
Invariants | Defined on this element vs-1: Datetime must be at least to day. (xpath: f:matches(effectiveDateTime,/\d{4}-[01]\d-[0-3]\dT[0-2]\d:[0-5]\d([+-][0-2]\d:[0-5]\d|Z)/)) |
Observation.issued | |
Element Id | Observation.issued |
Definition | The date and time this version of the observation was made available to providers, typically after the results have been reviewed and verified. |
Control | 0..1 |
Type | instant |
Comments | For Observations that don’t require review and verification, it may be the same as the |
Observation.performer | |
Element Id | Observation.performer |
Definition | Who was responsible for asserting the observed value as "true". |
Control | 0..* |
Type | Reference(Practitioner) |
Requirements | May give a degree of confidence in the observation and also indicates where follow-up questions should be directed. |
Observation.value[x] | |
Element Id | Observation.value[x] |
Definition | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. |
Control | 1..1 This element is affected by the following invariants: obs-7 |
Type | Quantity |
[x] Note | See Choice of Data Types for further information about how to use [x] |
Must Support | true |
Requirements |
|
Comments | An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below. |
Observation.value[x].id | |
Element Id | Observation.value[x].id |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
Observation.value[x].extension | |
Element Id | Observation.value[x].extension |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Slicing | This element introduces a set of slices. The slicing rules are:
|
Observation.value[x].value | |
Element Id | Observation.value[x].value |
Definition | The value of the measured amount. The value includes an implicit precision in the presentation of the value. |
Control | 1..1 |
Type | decimal |
Must Support | true |
Requirements | Precision is handled implicitly in almost all cases of measurement. |
Comments | The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books). |
Observation.value[x].comparator | |
Element Id | Observation.value[x].comparator |
Definition | How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value. |
Control | 0..1 |
Terminology Binding | How the Quantity should be understood and represented. The codes SHALL be taken from QuantityComparator |
Type | code |
Is Modifier | true (Reason: This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value) |
Requirements | Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology. |
Meaning if Missing | If there is no comparator, then there is no modification of the value |
Observation.value[x].unit | |
Element Id | Observation.value[x].unit |
Definition | A human-readable form of the unit. |
Control | 1..1 |
Type | string |
Must Support | true |
Requirements | There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms. |
Observation.value[x].system | |
Element Id | Observation.value[x].system |
Definition | The identification of the system that provides the coded form of the unit. |
Control | 1..1 This element is affected by the following invariants: qty-3 |
Type | uri |
Must Support | true |
Requirements | Need to know the system that defines the coded form of the unit. |
Fixed Value | http://unitsofmeasure.org |
Observation.value[x].code | |
Element Id | Observation.value[x].code |
Definition | Coded responses from the common UCUM units for vital signs value set. |
Control | 1..1 |
Type | code |
Must Support | true |
Requirements | Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest. |
Comments | The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system. |
Fixed Value | kg/m2 |
Observation.dataAbsentReason | |
Element Id | Observation.dataAbsentReason |
Definition | Provides a reason why the expected value in the element Observation.value[x] is missing. |
Control | 0..1 This element is affected by the following invariants: obs-6 |
Terminology Binding | Codes specifying why the result (`Observation.value[x]`) is missing. The codes SHALL be taken from DataAbsentReason; other codes may be used where these codes are not suitable |
Type | CodeableConcept |
Must Support | true |
Requirements | For many results it is necessary to handle exceptional values in measurements. |
Comments | Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values. |
Observation.interpretation | |
Element Id | Observation.interpretation |
Definition | The assessment made based on the result of the observation. Intended as a simple compact code often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result. Otherwise known as abnormal flag. |
Control | 0..1 |
Terminology Binding | Codes identifying interpretations of observations. The codes SHALL be taken from Observation Interpretation Codes; other codes may be used where these codes are not suitable |
Type | CodeableConcept |
Requirements | For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result. |
Alternate Names | Abnormal Flag |
Observation.comment | |
Element Id | Observation.comment |
Definition | May include statements about significant, unexpected or unreliable values, or information about the source of the value where this may be relevant to the interpretation of the result. |
Control | 0..1 |
Type | string |
Requirements | Need to be able to provide free text additional information. |
Observation.bodySite | |
Element Id | Observation.bodySite |
Definition | Indicates the site on the subject's body where the observation was made (i.e. the target site). |
Control | 0..1 |
Terminology Binding | Codes describing anatomical locations. May include laterality. For example codes, see SNOMED CT Body Structures |
Type | CodeableConcept |
Comments | Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension body-structure. |
Observation.method | |
Element Id | Observation.method |
Definition | Indicates the mechanism used to perform the observation. |
Control | 0..1 |
Terminology Binding | Methods for simple observations. For example codes, see Observation Methods |
Type | CodeableConcept |
Requirements | In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results. |
Comments | Only used if not implicit in code for Observation.code. |
Observation.specimen | |
Element Id | Observation.specimen |
Definition | The specimen that was used when this observation was made. |
Control | 0..1 |
Type | Reference(Specimen) |
Comments | Should only be used if not implicit in code found in |
Observation.device | |
Element Id | Observation.device |
Definition | The device used to generate the observation data. |
Control | 0..1 |
Type | Reference(Device) |
Comments | An extension should be used if further typing of the device is needed. Devices used to support obtaining an observation can be represented using an extension or the Provenance resource. (e.g., a device gateway such as a smart phone). |
Observation.referenceRange | |
Element Id | Observation.referenceRange |
Definition | Guidance on how to interpret the value by comparison to a normal or recommended range. |
Control | 0..* |
Type | BackboneElement |
Requirements | Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts. |
Comments | Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties. |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (xpath: @value|f:*|h:div) obs-3: Must have at least a low or a high or text (xpath: (exists(f:low) or exists(f:high)or exists(f:text))) |
Observation.referenceRange.id | |
Element Id | Observation.referenceRange.id |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
Observation.referenceRange.extension | |
Element Id | Observation.referenceRange.extension |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Observation.referenceRange.modifierExtension | |
Element Id | Observation.referenceRange.modifierExtension |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. |
Control | 0..* |
Type | Extension |
Is Modifier | true (Reason: modifierExtension is reserved for use where modifier extensions must be used) |
Alternate Names | extensions, user content, modifiers |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Observation.referenceRange.low | |
Element Id | Observation.referenceRange.low |
Definition | The value of the low bound of the reference range. The low bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3). |
Control | 0..1 This element is affected by the following invariants: obs-3 |
Type | Quantity(SimpleQuantity) |
Observation.referenceRange.high | |
Element Id | Observation.referenceRange.high |
Definition | The value of the high bound of the reference range. The high bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the high bound is omitted, it is assumed to be meaningless (e.g. reference range is >= 2.3). |
Control | 0..1 This element is affected by the following invariants: obs-3 |
Type | Quantity(SimpleQuantity) |
Observation.referenceRange.type | |
Element Id | Observation.referenceRange.type |
Definition | Codes to indicate the what part of the targeted reference population it applies to. For example, the normal or therapeutic range. |
Control | 0..1 |
Terminology Binding | Code for the meaning of a reference range. The codes SHALL be taken from Observation Reference Range Meaning Codes; other codes may be used where these codes are not suitable |
Type | CodeableConcept |
Requirements | Need to be able to say what kind of reference range this is - normal, recommended, therapeutic, etc., - for proper interpretation. |
Comments | This SHOULD be populated if there is more than one range. If this element is not present then the normal range is assumed. |
Observation.referenceRange.appliesTo | |
Element Id | Observation.referenceRange.appliesTo |
Definition | Codes to indicate the target population this reference range applies to. For example, a reference range may be based on the normal population or a particular sex or race. |
Control | 0..* |
Terminology Binding | Codes identifying the population the reference range applies to. For example codes, see Observation Reference Range Applies To Codes |
Type | CodeableConcept |
Requirements | Need to be able to identify the target population for proper interpretation. |
Comments | This SHOULD be populated if there is more than one range. If this element is not present then the normal population is assumed. |
Observation.referenceRange.age | |
Element Id | Observation.referenceRange.age |
Definition | The age at which this reference range is applicable. This is a neonatal age (e.g. number of weeks at term) if the meaning says so. |
Control | 0..1 |
Type | Range |
Requirements | Some analytes vary greatly over age. |
Observation.referenceRange.text | |
Element Id | Observation.referenceRange.text |
Definition | Text based reference range in an observation which may be used when a quantitative range is not appropriate for an observation. An example would be a reference value of "Negative" or a list or table of "normals". |
Control | 0..1 |
Type | string |
Observation.hasMember | |
Element Id | Observation.hasMember |
Definition | Used when reporting vital signs panel components. |
Control | 0..* |
Type | Reference(QuestionnaireResponse) |
Comments | When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. |
Observation.derivedFrom | |
Element Id | Observation.derivedFrom |
Definition | The target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image. |
Control | 0..* |
Type | Reference(DocumentReference) |
Comments | All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see Notes below. |
Observation.component | |
Element Id | Observation.component |
Definition | Used when reporting systolic and diastolic blood pressure. |
Control | 0..* |
Type | BackboneElement |
Must Support | true |
Requirements | Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation. |
Comments | For a discussion on the ways Observations can be assembled in groups together see Notes below. |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (xpath: @value|f:*|h:div) vs-3: If there is no a value a data absent reason must be present (xpath: f:*[starts-with(local-name(.), 'value')] or f:dataAbsentReason) |
Observation.component.id | |
Element Id | Observation.component.id |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
Observation.component.extension | |
Element Id | Observation.component.extension |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Observation.component.modifierExtension | |
Element Id | Observation.component.modifierExtension |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. |
Control | 0..* |
Type | Extension |
Is Modifier | true (Reason: modifierExtension is reserved for use where modifier extensions must be used) |
Alternate Names | extensions, user content, modifiers |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Observation.component.code | |
Element Id | Observation.component.code |
Definition | Describes what was observed. Sometimes this is called the observation "code". |
Control | 1..1 |
Terminology Binding | This identifies the vital sign result type. The codes SHALL be taken from Vital Signs; other codes may be used where these codes are not suitable |
Type | CodeableConcept |
Must Support | true |
Requirements | Knowing what kind of observation is being made is essential to understanding the observation. |
Comments | All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation. |
Observation.component.value[x] | |
Element Id | Observation.component.value[x] |
Definition | Vital Sign Value recorded with UCUM. |
Control | 0..1 |
Terminology Binding | Common UCUM units for recording Vital Signs The codes SHALL be taken from Vital Signs Units |
Type | Choice of: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period |
[x] Note | See Choice of Data Types for further information about how to use [x] |
Must Support | true |
Requirements |
|
Comments | Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below. |
Observation.component.dataAbsentReason | |
Element Id | Observation.component.dataAbsentReason |
Definition | Provides a reason why the expected value in the element Observation.component.value[x] is missing. |
Control | 0..1 This element is affected by the following invariants: obs-6 |
Terminology Binding | Codes specifying why the result (`Observation.value[x]`) is missing. The codes SHALL be taken from DataAbsentReason; other codes may be used where these codes are not suitable |
Type | CodeableConcept |
Must Support | true |
Requirements | For many results it is necessary to handle exceptional values in measurements. |
Comments | "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values. |
Observation.component.interpretation | |
Element Id | Observation.component.interpretation |
Definition | The assessment made based on the result of the observation. Intended as a simple compact code often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result. Otherwise known as abnormal flag. |
Control | 0..1 |
Terminology Binding | Codes identifying interpretations of observations. The codes SHALL be taken from Observation Interpretation Codes; other codes may be used where these codes are not suitable |
Type | CodeableConcept |
Requirements | For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result. |
Alternate Names | Abnormal Flag |
Comments | The component interpretation applies only to the individual component value. For an overall interpretation all components together use the Observation.interpretation element. |
Observation.component.referenceRange | |
Element Id | Observation.component.referenceRange |
Definition | Guidance on how to interpret the value by comparison to a normal or recommended range. |
Control | 0..* |
Type | See Observation.referenceRange |
Requirements | Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts. |
Comments | Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties. |