This page is part of the Point-of-care Device FHIR IG (v0.2.0: STU 1 Ballot 2) based on FHIR v3.5.0. . For a full list of available versions, see the Directory of published versions
This is a pre-release version (Ballot 2) of Point of Care Devices (PoCD) R1/STU. There is no current official version.
For a full list of available versions, see the Directory of published versions .
<DeviceMetric xmlns="http://hl7.org/fhir"> <id value="2f26a717-9841-4ddc-92eb-26398c7548c7"/> <meta> <profile value="http://hl7.org/fhir/uv/pocd/StructureDefinition/NumericDeviceMetric"/> </meta> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: 2f26a717-9841-4ddc-92eb-26398c7548c7</p><p><b>meta</b>: </p><p><b>type</b>: NBP <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '150020' = '150020', given as 'MDC_PRESS_BLD_NONINV'})</span></p><p><b>unit</b>: mmHg <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '266016' = '266016', given as 'MDC_DIM_MMHG'})</span></p><p><b>source</b>: <a href="Device-5205082c-1f88-434e-9252-6c6b09c81a0d.html">Generated Summary: id: 5205082c-1f88-434e-9252-6c6b09c81a0d; 00-09-FB-FF-FF-A0-F4-CA; status: active; manufacturer: MyCompany; serialNumber: DE35115712; partNumber: 866060; <span title="Codes: {urn:iso:std:iso:11073:10101 69965}">Patient Monitor</span></a></p><p><b>parent</b>: <a href="Device-2b7069bf-65a4-4226-a2ba-9af47197074f.html">Generated Summary: id: 2b7069bf-65a4-4226-a2ba-9af47197074f; status: active; <span title="Codes: {urn:iso:std:iso:11073:10101 69855}">MDC_DEV_METER_PRESS_BLD_CHAN</span></a></p><p><b>operationalStatus</b>: ON</p><p><b>color</b>: RED</p><p><b>category</b>: MEASUREMENT</p><p><b>measurementPeriod</b>: Do Once per 15 minutes</p></div> </text> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="150020"/> <display value="MDC_PRESS_BLD_NONINV"/> </coding> <text value="NBP"/> </type> <unit> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="266016"/> <display value="MDC_DIM_MMHG"/> </coding> <text value="mmHg"/> </unit> <source> <reference value="Device/5205082c-1f88-434e-9252-6c6b09c81a0d"/> </source> <parent> <reference value="Device/2b7069bf-65a4-4226-a2ba-9af47197074f"/> </parent> <operationalStatus value="on"/> <color value="red"/> <category value="measurement"/> <measurementPeriod> <repeat> <frequency value="1"/> <period value="15"/> <periodUnit value="min"/> </repeat> </measurementPeriod> </DeviceMetric>