This page is part of the Point-of-care Device FHIR IG (v0.2.0: STU 1 Ballot 2) based on FHIR v3.5.0. . For a full list of available versions, see the Directory of published versions

This is a pre-release version (Ballot 2) of Point of Care Devices (PoCD) R1/STU. There is no current official version.
For a full list of available versions, see the Directory of published versions .



<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="measurement-status"/>
  <meta>
    <profile value="http://hl7.org/fhir/StructureDefinition/shareablecodesystem"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><h2>Measurement status codes</h2><div><p>Measurement status definitions from the ISO/IEEE 11073-10201 DIM.</p>
</div><p>This code system http://hl7.org/fhir/uv/pocd/CodeSystem/measurement-status defines the following codes:</p><table class="codes"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td style="white-space:nowrap">questionable<a name="measurement-status-questionable"> </a></td><td>Questionable</td><td>Data may not be reliable</td></tr><tr><td style="white-space:nowrap">calibration-ongoing<a name="measurement-status-calibration-ongoing"> </a></td><td>Calibration ongoing</td><td>Calibration is ongoing</td></tr><tr><td style="white-space:nowrap">validated-data<a name="measurement-status-validated-data"> </a></td><td>Validated data</td><td>Relevant, e.g., in an archive</td></tr><tr><td style="white-space:nowrap">early-indication<a name="measurement-status-early-indication"> </a></td><td>Early indication</td><td>Early estimate of value</td></tr><tr><td style="white-space:nowrap">msmt-ongoing<a name="measurement-status-msmt-ongoing"> </a></td><td>Measurement ongoing</td><td>Indicates that a new measurement is just being taken</td></tr><tr><td style="white-space:nowrap">in-alarm<a name="measurement-status-in-alarm"> </a></td><td>Measurement in alarm</td><td>Measurement has an active alarm condition</td></tr><tr><td style="white-space:nowrap">alarm-inhibited<a name="measurement-status-alarm-inhibited"> </a></td><td>Measurement alarms inhibited</td><td>Measurement supports alarming and alarms are turned off</td></tr></table></div>
  </text>
  <url value="http://hl7.org/fhir/uv/pocd/CodeSystem/measurement-status"/>
  <version value="0.2.0"/>
  <name value="MeasurementStatus"/>
  <title value="Measurement status codes"/>
  <status value="draft"/>
  <experimental value="false"/>
  <date value="2018-08-07"/>
  <publisher
             value="Health Level Seven International (Health Care Devices Work Group)"/>
  <description
               value="Measurement status definitions from the ISO/IEEE 11073-10201 DIM."/>
  <caseSensitive value="false"/>
  <content value="complete"/>
  <concept>
    <code value="questionable"/>
    <display value="Questionable"/>
    <definition value="Data may not be reliable"/>
  </concept>
  <concept>
    <code value="calibration-ongoing"/>
    <display value="Calibration ongoing"/>
    <definition value="Calibration is ongoing"/>
  </concept>
  <concept>
    <code value="validated-data"/>
    <display value="Validated data"/>
    <definition value="Relevant, e.g., in an archive"/>
  </concept>
  <concept>
    <code value="early-indication"/>
    <display value="Early indication"/>
    <definition value="Early estimate of value"/>
  </concept>
  <concept>
    <code value="msmt-ongoing"/>
    <display value="Measurement ongoing"/>
    <definition value="Indicates that a new measurement is just being taken"/>
  </concept>
  <concept>
    <code value="in-alarm"/>
    <display value="Measurement in alarm"/>
    <definition value="Measurement has an active alarm condition"/>
  </concept>
  <concept>
    <code value="alarm-inhibited"/>
    <display value="Measurement alarms inhibited"/>
    <definition value="Measurement supports alarming and alarms are turned off"/>
  </concept>
</CodeSystem>