This page is part of the CardX - Cardiac Implantable Electronic Devices (v1.0.0-ballot: STU 1 Ballot 1) based on FHIR (HL7® FHIR® Standard) v5.0.0. No current official version has been published yet. For a full list of available versions, see the Directory of published versions
Page standards status: Informative |
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdf: <http://www.w3.org/1999/02/22-rdf-syntax-ns#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
a fhir:Observation ;
fhir:nodeRole fhir:treeRoot ;
fhir:id [ fhir:v "uc2ConnectivityACME"] ; #
fhir:meta [
( fhir:profile [
fhir:v "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-connectivity-status"^^xsd:anyURI ;
fhir:link <http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-connectivity-status> ] )
] ; #
fhir:text [
fhir:status [ fhir:v "extensions" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Observation uc2ConnectivityACME</b></p><a name=\"uc2ConnectivityACME\"> </a><a name=\"hcuc2ConnectivityACME\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\"/><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-cied-connectivity-status.html\">Observation - CIED Connectivity</a></p></div><p><b>CIED Device Extension</b>: <a href=\"Device-uc2ACMEPacemaker.html\">Device: manufacturer = ACME Devices; serialNumber = uc2ACMEPacemaker; modelNumber = PacemakerExample2; type = Defibrillator</a></p><p><b>status</b>: Final</p><p><b>category</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity observation-cied-connectivity}\">CIED connectivity</span></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity observation-cied-connectivity}\">CIED connectivity</span></p><p><b>subject</b>: <a href=\"Patient-uc2ACMEPatient.html\">John ACME Doe (no stated gender), DoB: 1954-01-01 ( http://example.org#ACME2222 (use: official, ))</a></p><p><b>effective</b>: 2025-05-19 08:00:00+0000</p><p><b>note</b>: </p><blockquote><div><p>The patient has been disconnected for more than 90 days and is listed as inactive.</p>\n</div></blockquote><p><b>device</b>: <a href=\"Device-uc2CIEDMonitor.html\">Device: manufacturer = ACME Devices; serialNumber = uc2ACMEMonitor; modelNumber = SmartApp Monitor 1; type = Mobile App</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity connectivity-status}\">Connectivity status</span></p><p><b>value</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity disconnected}\">Disconnected</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity connectivity-modifier}\">Connectivity modifier</span></p><p><b>value</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity inactive}\">Inactive</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity last-cied-connectivity-time}\">Last CIED to monitor communication</span></p><p><b>value</b>: 2025-02-19 06:00:00+0000</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity last-monitor-connectivity-time}\">Last monitor to remote monitoring software communication</span></p><p><b>value</b>: 2025-02-19 06:00:00+0000</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity next-cied-connectivity-date}\">Next CIED to monitor communication</span></p><p><b>value</b>: 2025-05-20</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity next-monitor-connectivity-date}\">Next monitor to remote monitoring software communication</span></p><p><b>value</b>: 2025-05-20</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity last-interrogation-date}\">Last remote device interrogation date</span></p><p><b>value</b>: 2025-02-08 06:00:00+0000</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity next-interrogation-date}\">Next scheduled remote device interrogation date</span></p><p><b>value</b>: 2025-05-30</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity connection-interval}\">Connection interval</span></p><p><b>value</b>: 14</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity expected-time-period}\">Expected time period</span></p><p><b>value</b>: 14</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity status-reason}\">Status reason</span></p><p><b>value</b>: The patient has not connected for more than 90 days and is listed as inactive.</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity status-guidance}\">Status guidance</span></p><p><b>value</b>: The patient should be contacted to determine if they are still using the device and if they wish to continue remote monitoring.</p></blockquote></div>"^^rdf:XMLLiteral
] ; #
fhir:extension ( [
fhir:url [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-device-extension"^^xsd:anyURI ] ;
fhir:value [
a fhir:Reference ;
fhir:reference [ fhir:v "Device/uc2ACMEPacemaker" ] ]
] ) ; #
fhir:status [ fhir:v "final"] ; #
fhir:category ( [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "observation-cied-connectivity" ] ] )
] ) ; #
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "observation-cied-connectivity" ] ] )
] ; #
fhir:subject [
fhir:reference [ fhir:v "Patient/uc2ACMEPatient" ]
] ; #
fhir:effective [
a fhir:dateTime ;
fhir:v "2025-05-19T08:00:00.000Z"^^xsd:dateTime
] ; #
fhir:note ( [
fhir:text [ fhir:v "The patient has been disconnected for more than 90 days and is listed as inactive." ]
] ) ; #
fhir:device [
fhir:reference [ fhir:v "Device/uc2CIEDMonitor" ]
] ; #
fhir:component ( [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "connectivity-status" ] ] ) ] ;
fhir:value [
a fhir:CodeableConcept ;
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "disconnected" ] ] ) ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "connectivity-modifier" ] ] ) ] ;
fhir:value [
a fhir:CodeableConcept ;
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "inactive" ] ] ) ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "last-cied-connectivity-time" ] ] ) ] ;
fhir:value [
a fhir:dateTime ;
fhir:v "2025-02-19T06:00:00.000Z"^^xsd:dateTime ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "last-monitor-connectivity-time" ] ] ) ] ;
fhir:value [
a fhir:dateTime ;
fhir:v "2025-02-19T06:00:00.000Z"^^xsd:dateTime ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "next-cied-connectivity-date" ] ] ) ] ;
fhir:value [
a fhir:dateTime ;
fhir:v "2025-05-20"^^xsd:date ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "next-monitor-connectivity-date" ] ] ) ] ;
fhir:value [
a fhir:dateTime ;
fhir:v "2025-05-20"^^xsd:date ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "last-interrogation-date" ] ] ) ] ;
fhir:value [
a fhir:dateTime ;
fhir:v "2025-02-08T06:00:00.000Z"^^xsd:dateTime ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "next-interrogation-date" ] ] ) ] ;
fhir:value [
a fhir:dateTime ;
fhir:v "2025-05-30"^^xsd:date ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "connection-interval" ] ] ) ] ;
fhir:value [
a fhir:integer ;
fhir:v 14 ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "expected-time-period" ] ] ) ] ;
fhir:value [
a fhir:integer ;
fhir:v 14 ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "status-reason" ] ] ) ] ;
fhir:value [
a fhir:string ;
fhir:v "The patient has not connected for more than 90 days and is listed as inactive." ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"^^xsd:anyURI ] ;
fhir:code [ fhir:v "status-guidance" ] ] ) ] ;
fhir:value [
a fhir:string ;
fhir:v "The patient should be contacted to determine if they are still using the device and if they wish to continue remote monitoring." ]
] ) . #
IG © 2025+ HL7 International / Clinical Interoperability Council. Package hl7.fhir.uv.cardx-cied#1.0.0-ballot based on FHIR 5.0.0. Generated 2025-07-31
Links: Table of Contents |
QA Report
| Version History |
|
Propose a change