US Core Implementation Guide
7.0.0 - STU7 United States of America flag

This page is part of the US Core (v7.0.0: STU7) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions. Page versions: STU6.1 STU6 STU5 STU4 STU3

Resource Profile: US Core Implantable Device Profile

Official URL: http://hl7.org/fhir/us/core/StructureDefinition/us-core-implantable-device Version: 7.0.0
Standards status: Trial-use Maturity Level: 3 Computable Name: USCoreImplantableDeviceProfile
Other Identifiers: OID:2.16.840.1.113883.4.642.40.2.42.29

Copyright/Legal: Used by permission of HL7 International, all rights reserved Creative Commons License

The US Core Device Profile inherits from the FHIR Device resource; refer to it for scope and usage definitions. This profile meets the requirements of the U.S. Core Data for Interoperability (USCDI) Unique Device Identifier - Implantable Data Element. It sets minimum expectations for the Device resource to record, search, and fetch UDI information associated with a patient’s implantable device(s). It specifies which core elements, extensions, vocabularies, and value sets SHALL be present in the resource and constrains how the elements are used. Providing the floor for standards development for specific use cases promotes interoperability and adoption.

Example Usage Scenarios:

The following are example usage scenarios for this profile:

  • Query for a Patient’s Implantable Devices
  • Record or update a Patient Implantable Device

Mandatory and Must Support Data Elements

The following data elements must always be present (Mandatory definition) or must be supported if the data is present in the sending system (Must Support definition). They are presented below in a simple human-readable explanation. Profile specific guidance and examples are provided as well. The Formal Views below provides the formal summary, definitions, and terminology requirements.

Each Implantable Device Must Have:

  1. a code identifying the type of device
  2. a patient

In addition, the following data elements must be supported if the data is present in the sending system (Must Support definition):

Each Implantable Device Must Support:

  1. A Unique Device Identifier (UDI) numeric or alphanumeric code as the Human Readable Form (HRF) string representation of the barcode
  2. The Device Identifier (UDI-DI)
  3. the manufacture date
  4. the expiration date
  5. the lot number
  6. the serial number
  7. the distinct identifier (i.e., the distinct identification code)

Profile Specific Implementation Guidance:

  • For non-implantable devices (for example, software or crutches), use the base FHIR Device resource or other use case-specific Device profiles.
  • This profile supports the requirement to retrieve a 170.315(a)(14) Implantable device list. It follows the HL7 Cross Paradigm Implementation Guide: UDI Pattern guidelines for exchanging information about the use and implantation of medical devices in patients.
    • A unique device identifier (UDI) is a unique numeric or alphanumeric code. There is a machine-readable version (AIDC - the Automatic Identification and Data Capture) and a human-readable version of the UDI (HRF - Human Readable Form string). This profile specifies that only the HRF must be supported. Considering the complexity of parsing AIDCs, there is no expectation at this time that one converts an AIDC to HRF upon receipt from a FHIR source that is not conformant to this profile or is using another interchange standard (e.g., C-CDA, HL7 v2, etc.). The UDI generally consists of a mandatory Device Identifier (DI) and a conditional Production identifier (PI) that identifies one or more of the five UDI-PI elements. The UDI and its components are mapped to the US Core Implantable Device Profile elements in the table below:

      UDI component US Core Implantable Device Profile element
      UDI HRF string Device.udiCarrier.carrierHRF
      DI Device.udiCarrier.deviceIdentifier
      manufacture date (UDI-PI element) Device.manufactureDate
      expiration dat (UDI-PI elemente Device.expirationDate
      lot number (UDI-PI element) Device.lotNumber
      serial number (UDI-PI element) Device.serialNumber
      distinct identifier (UDI-PI element) Device.distinctIdentifier
    • Implementers are encouraged to use the FDA Global UDI Database (GUDID) and associated APIs to parse and validate the UDI:

      • The AccessGUDID API provides access to device records in GUDID, including safety information and UDI. It includes APIs to query and download a complete list of implantable devices registered in GUDID.
      • The Parse UDI API allows users to pass a UDI and return each part of the UDI in a structured format (specifically the serialNumber, lotNumber, expirationDate, distinctIdentifier (returned as donation_id) or manufactureDate).
  • Implantable medical devices with UDI information SHALL represent the UDI code in Device.udiCarrier.carrierHRF. All five UDI-PI elements defined in the UDI code may not always be present in every UDI instance. However, those UDI-PI elements present SHALL be represented in the corresponding US Core Implantable Device Profile elements.

    UDI may not be present in all scenarios, such as historical implantable devices, patient-reported implant information, payer-reported devices, or improperly documented implants. If UDI is not present and the manufacturer or model number information is available, they SHOULD be included to support historical reports of implantable medical devices as follows:

    data element US Core Implantable Device Profile element
    manufacturer Device.manufacturer
    model Device.model
  • Servers SHOULD support query by Device.type to allow clients to request the patient’s devices by a specific type. Note: Device.type is too granular to differentiate implantable vs. non-implantable devices.
  • The Quick Start section below describes searching for all devices. Records of implanted devices MAY be queried against UDI data, including:

    • UDI HRF string (udi-carrier)
    • UDI Device Identifier (udi-di)
    • Manufacturer (manufacturer)
    • Model number (model)

    Implementers MAY also adopt custom SearchParameters for searching by:

    • lot numbers
    • serial number
    • expiration date
    • manufacture date
    • distinct identifier

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from Device

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* Device Item used in healthcare
... udiCarrier S 0..1 BackboneElement Unique Device Identifier (UDI) Barcode string
.... deviceIdentifier S 1..1 string Mandatory fixed portion of UDI
.... carrierHRF S 0..1 string UDI Human Readable Barcode String
... distinctIdentifier S 0..1 string The distinct identification string
... manufactureDate S 0..1 dateTime Date when the device was made
... expirationDate S 0..1 dateTime Date and time of expiry of this device (if applicable)
... lotNumber S 0..1 string Lot number of manufacture
... serialNumber S 0..1 string Serial number assigned by the manufacturer
... type S 1..1 CodeableConcept The kind or type of device
Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices

... patient S 1..1 Reference(US Core Patient Profile) Patient to whom Device is affixed

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Device.typeextensibleFHIRDeviceTypes
http://hl7.org/fhir/ValueSet/device-kind
from the FHIR Standard
NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* Device Item used in healthcare
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... udiCarrier SΣ 0..1 BackboneElement Unique Device Identifier (UDI) Barcode string
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... deviceIdentifier SΣ 1..1 string Mandatory fixed portion of UDI
.... carrierHRF SΣ 0..1 string UDI Human Readable Barcode String
... status ?!Σ 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... distinctIdentifier S 0..1 string The distinct identification string
... manufactureDate S 0..1 dateTime Date when the device was made
... expirationDate S 0..1 dateTime Date and time of expiry of this device (if applicable)
... lotNumber S 0..1 string Lot number of manufacture
... serialNumber S 0..1 string Serial number assigned by the manufacturer
... type S 1..1 CodeableConcept The kind or type of device
Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices

... patient S 1..1 Reference(US Core Patient Profile) Patient to whom Device is affixed

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.typeextensibleFHIRDeviceTypes
http://hl7.org/fhir/ValueSet/device-kind
from the FHIR Standard
NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* Device Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier 0..* Identifier Instance identifier
... definition 0..1 Reference(DeviceDefinition) The reference to the definition for the device
... udiCarrier SΣ 0..1 BackboneElement Unique Device Identifier (UDI) Barcode string
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... deviceIdentifier SΣ 1..1 string Mandatory fixed portion of UDI
.... issuer 0..1 uri UDI Issuing Organization
.... jurisdiction 0..1 uri Regional UDI authority
.... carrierAIDC Σ 0..1 base64Binary UDI Machine Readable Barcode String
.... carrierHRF SΣ 0..1 string UDI Human Readable Barcode String
.... entryType 0..1 code barcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.

... status ?!Σ 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.


... distinctIdentifier S 0..1 string The distinct identification string
... manufacturer 0..1 string Name of device manufacturer
... manufactureDate S 0..1 dateTime Date when the device was made
... expirationDate S 0..1 dateTime Date and time of expiry of this device (if applicable)
... lotNumber S 0..1 string Lot number of manufacture
... serialNumber S 0..1 string Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... modelNumber 0..1 string The model number for the device
... partNumber 0..1 string The part number of the device
... type S 1..1 CodeableConcept The kind or type of device
Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices

... specialization 0..* BackboneElement The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... systemType 1..1 CodeableConcept The standard that is used to operate and communicate
.... version 0..1 string The version of the standard that is used to operate and communicate
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... property 0..* BackboneElement The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 1..1 CodeableConcept Code that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..* Quantity Property value as a quantity
.... valueCode 0..* CodeableConcept Property value as a code, e.g., NTP4 (synced to NTP)
... patient S 1..1 Reference(US Core Patient Profile) Patient to whom Device is affixed
... owner 0..1 Reference(Organization) Organization responsible for device
... contact 0..* ContactPoint Details for human/organization for support
... location 0..1 Reference(Location) Where the device is found
... url 0..1 uri Network address to contact device
... note 0..* Annotation Device notes and comments
... safety Σ 0..* CodeableConcept Safety Characteristics of Device
... parent 0..1 Reference(Device) The parent device

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.languagepreferredCommonLanguages
Additional Bindings Purpose
AllLanguages Max Binding
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Device.udiCarrier.entryTyperequiredUDIEntryType
http://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1
from the FHIR Standard
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.statusReasonextensibleFHIRDeviceStatusReason
http://hl7.org/fhir/ValueSet/device-status-reason
from the FHIR Standard
Device.deviceName.typerequiredDeviceNameType
http://hl7.org/fhir/ValueSet/device-nametype|4.0.1
from the FHIR Standard
Device.typeextensibleFHIRDeviceTypes
http://hl7.org/fhir/ValueSet/device-kind
from the FHIR Standard

This structure is derived from Device

Summary

Mandatory: 2 elements(1 nested mandatory element)
Must-Support: 10 elements

Structures

This structure refers to these other structures:

Maturity: 3

Differential View

This structure is derived from Device

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* Device Item used in healthcare
... udiCarrier S 0..1 BackboneElement Unique Device Identifier (UDI) Barcode string
.... deviceIdentifier S 1..1 string Mandatory fixed portion of UDI
.... carrierHRF S 0..1 string UDI Human Readable Barcode String
... distinctIdentifier S 0..1 string The distinct identification string
... manufactureDate S 0..1 dateTime Date when the device was made
... expirationDate S 0..1 dateTime Date and time of expiry of this device (if applicable)
... lotNumber S 0..1 string Lot number of manufacture
... serialNumber S 0..1 string Serial number assigned by the manufacturer
... type S 1..1 CodeableConcept The kind or type of device
Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices

... patient S 1..1 Reference(US Core Patient Profile) Patient to whom Device is affixed

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Device.typeextensibleFHIRDeviceTypes
http://hl7.org/fhir/ValueSet/device-kind
from the FHIR Standard

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* Device Item used in healthcare
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... udiCarrier SΣ 0..1 BackboneElement Unique Device Identifier (UDI) Barcode string
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... deviceIdentifier SΣ 1..1 string Mandatory fixed portion of UDI
.... carrierHRF SΣ 0..1 string UDI Human Readable Barcode String
... status ?!Σ 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... distinctIdentifier S 0..1 string The distinct identification string
... manufactureDate S 0..1 dateTime Date when the device was made
... expirationDate S 0..1 dateTime Date and time of expiry of this device (if applicable)
... lotNumber S 0..1 string Lot number of manufacture
... serialNumber S 0..1 string Serial number assigned by the manufacturer
... type S 1..1 CodeableConcept The kind or type of device
Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices

... patient S 1..1 Reference(US Core Patient Profile) Patient to whom Device is affixed

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.typeextensibleFHIRDeviceTypes
http://hl7.org/fhir/ValueSet/device-kind
from the FHIR Standard

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* Device Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier 0..* Identifier Instance identifier
... definition 0..1 Reference(DeviceDefinition) The reference to the definition for the device
... udiCarrier SΣ 0..1 BackboneElement Unique Device Identifier (UDI) Barcode string
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... deviceIdentifier SΣ 1..1 string Mandatory fixed portion of UDI
.... issuer 0..1 uri UDI Issuing Organization
.... jurisdiction 0..1 uri Regional UDI authority
.... carrierAIDC Σ 0..1 base64Binary UDI Machine Readable Barcode String
.... carrierHRF SΣ 0..1 string UDI Human Readable Barcode String
.... entryType 0..1 code barcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.

... status ?!Σ 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.


... distinctIdentifier S 0..1 string The distinct identification string
... manufacturer 0..1 string Name of device manufacturer
... manufactureDate S 0..1 dateTime Date when the device was made
... expirationDate S 0..1 dateTime Date and time of expiry of this device (if applicable)
... lotNumber S 0..1 string Lot number of manufacture
... serialNumber S 0..1 string Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... modelNumber 0..1 string The model number for the device
... partNumber 0..1 string The part number of the device
... type S 1..1 CodeableConcept The kind or type of device
Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices

... specialization 0..* BackboneElement The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... systemType 1..1 CodeableConcept The standard that is used to operate and communicate
.... version 0..1 string The version of the standard that is used to operate and communicate
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... property 0..* BackboneElement The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 1..1 CodeableConcept Code that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..* Quantity Property value as a quantity
.... valueCode 0..* CodeableConcept Property value as a code, e.g., NTP4 (synced to NTP)
... patient S 1..1 Reference(US Core Patient Profile) Patient to whom Device is affixed
... owner 0..1 Reference(Organization) Organization responsible for device
... contact 0..* ContactPoint Details for human/organization for support
... location 0..1 Reference(Location) Where the device is found
... url 0..1 uri Network address to contact device
... note 0..* Annotation Device notes and comments
... safety Σ 0..* CodeableConcept Safety Characteristics of Device
... parent 0..1 Reference(Device) The parent device

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.languagepreferredCommonLanguages
Additional Bindings Purpose
AllLanguages Max Binding
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Device.udiCarrier.entryTyperequiredUDIEntryType
http://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1
from the FHIR Standard
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.statusReasonextensibleFHIRDeviceStatusReason
http://hl7.org/fhir/ValueSet/device-status-reason
from the FHIR Standard
Device.deviceName.typerequiredDeviceNameType
http://hl7.org/fhir/ValueSet/device-nametype|4.0.1
from the FHIR Standard
Device.typeextensibleFHIRDeviceTypes
http://hl7.org/fhir/ValueSet/device-kind
from the FHIR Standard

This structure is derived from Device

Summary

Mandatory: 2 elements(1 nested mandatory element)
Must-Support: 10 elements

Structures

This structure refers to these other structures:

Maturity: 3

 

Other representations of profile: CSV, Excel, Schematron

Notes:


Quick Start


Below is an overview of the required Server RESTful FHIR interactions for this profile - for example, search and read operations - when supporting the US Core interactions to access this profile’s information (Profile Support + Interaction Support). Note that systems that support only US Core Profiles (Profile Only Support) are not required to support these interactions. See the US Core Server CapabilityStatement for a complete list of supported RESTful interactions for this IG.

  • See the Scopes Format section for a description of the SMART scopes syntax.
  • See the Search Syntax section for a description of the US Core search syntax.
  • See the General Requirements section for additional rules and expectations when a server requires status parameters.
  • See the General Guidance section for additional guidance on searching for multiple patients.

US Core Scopes

Servers providing access to implantable device data SHALL support these US Core SMART Scopes:

Mandatory Search Parameters:

  1. SHALL support searching for all devices for a patient, including implantable devices using the patient search parameter:

    GET [base]/Device?patient={Type/}[id]

    Example:

    1. GET [base]/Device?patient=1137192

    Implementation Notes: Fetches a bundle of all Device resources for the specified patient (how to search by reference)

Optional Search Parameters:

The following search parameter combinations SHOULD be supported:

  1. SHOULD support searching using the combination of the patient and type search parameters:

    GET [base]/Device?patient={Type/}[id]&type={system|}[code]

    Example:

    1. GET [base]/Device?patient=1316024&type=http://snomed.info/sct|468063009

    Implementation Notes: Fetches a bundle of all Device resources for the specified patient and type. (how to search by reference and how to search by token)

  2. SHOULD support searching using the combination of the patient and status search parameters:

    • including support for OR search on status (e.g.status={system|}[code],{system|}[code],...)

    GET [base]/Device?patient={Type/}[id]&status={system|}[code]{,{system|}[code],...}

    Example:

    1. GET [base]/Device?patient=1316024&status=active

    Implementation Notes: Fetches a bundle of all Device resources for the specified patient and status (how to search by reference and how to search by token)