This page is part of the US Core (v8.0.0-ballot: STU8 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 7.0.0. For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/core/StructureDefinition/us-core-implantable-device | Version: 8.0.0-ballot | |||
Standards status: Trial-use | Maturity Level: 3 | Computable Name: USCoreImplantableDeviceProfile | ||
Other Identifiers: OID:2.16.840.1.113883.4.642.40.2.42.32 | ||||
Copyright/Legal: Used by permission of HL7 International, all rights reserved Creative Commons License |
The US Core Device Profile inherits from the FHIR Device resource; refer to it for scope and usage definitions. This profile meets the requirements of the U.S. Core Data for Interoperability (USCDI) Unique Device Identifier - Implantable Data Element. It sets minimum expectations for the Device resource to record, search, and fetch UDI information associated with a patient's implantable device(s). It specifies which core elements, extensions, vocabularies, and value sets SHALL be present in the resource and constrains how the elements are used. Providing the floor for standards development for specific use cases promotes interoperability and adoption.
Example Usage Scenarios:
The following are example usage scenarios for this profile:
The following data elements must always be present (Mandatory definition) or must be supported if the data is present in the sending system (Must Support definition). They are presented below in a simple human-readable explanation. Profile specific guidance and examples are provided as well. The Formal Views below provides the formal summary, definitions, and terminology requirements.
Each Implantable Device Must Have:
In addition, the following data elements must be supported if the data is present in the sending system (Must Support definition):
Each Implantable Device Must Support:
Profile Specific Implementation Guidance:
A unique device identifier (UDI) is a unique numeric or alphanumeric code. There is a machine-readable version (AIDC - the Automatic Identification and Data Capture) and a human-readable version of the UDI (HRF - Human Readable Form string). This profile specifies that only the HRF must be supported. Considering the complexity of parsing AIDCs, there is no expectation at this time that one converts an AIDC to HRF upon receipt from a FHIR source that is not conformant to this profile or is using another interchange standard (e.g., C-CDA, HL7 v2, etc.). The UDI generally consists of a mandatory Device Identifier (DI) and a conditional Production identifier (PI) that identifies one or more of the five UDI-PI elements. The UDI and its components are mapped to the US Core Implantable Device Profile elements in the table below:
UDI component | US Core Implantable Device Profile element |
---|---|
UDI HRF string | Device.udiCarrier.carrierHRF |
DI | Device.udiCarrier.deviceIdentifier |
manufacture date (UDI-PI element) | Device.manufactureDate |
expiration dat (UDI-PI elemente | Device.expirationDate |
lot number (UDI-PI element) | Device.lotNumber |
serial number (UDI-PI element) | Device.serialNumber |
distinct identifier (UDI-PI element) | Device.distinctIdentifier |
Implementers are encouraged to use the FDA Global UDI Database (GUDID) and associated APIs to parse and validate the UDI:
Implantable medical devices with UDI information SHALL represent the UDI code in Device.udiCarrier.carrierHRF
. All five UDI-PI elements defined in the UDI code may not always be present in every UDI instance. However, those UDI-PI elements present SHALL be represented in the corresponding US Core Implantable Device Profile elements.
UDI may not be present in all scenarios, such as historical implantable devices, patient-reported implant information, payer-reported devices, or improperly documented implants. If UDI is not present and the manufacturer or model number information is available, they SHOULD be included to support historical reports of implantable medical devices as follows:
data element | US Core Implantable Device Profile element |
---|---|
manufacturer | Device.manufacturer |
model | Device.model |
Device.type
to allow Clients to request the patient's devices by a specific type. Note: Device.type
is too granular to differentiate implantable vs. non-implantable devices.The Quick Start section below describes searching for all devices. Records of implanted devices MAY be queried against UDI data, including:
udi-carrier
)udi-di
)manufacturer
)model
)Implementers MAY also adopt custom SearchParameters for searching by:
Usage:
Changes since version 7.0.0:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |
udiCarrier | S | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
deviceIdentifier | S | 1..1 | string | Mandatory fixed portion of UDI |
carrierHRF | S | 0..1 | string | UDI Human Readable Barcode String |
distinctIdentifier | S | 0..1 | string | The distinct identification string |
manufactureDate | S | 0..1 | dateTime | Date when the device was made |
expirationDate | S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) |
lotNumber | S | 0..1 | string | Lot number of manufacture |
serialNumber | S | 0..1 | string | Serial number assigned by the manufacturer |
type | S | 1..1 | CodeableConcept | The kind or type of device Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices |
patient | S | 1..1 | Reference(US Core Patient Profile) | Patient to whom Device is affixed |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.type | extensible | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
udiCarrier | SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
deviceIdentifier | SΣ | 1..1 | string | Mandatory fixed portion of UDI ele-1: All FHIR elements must have a @value or children |
carrierHRF | SΣ | 0..1 | string | UDI Human Readable Barcode String ele-1: All FHIR elements must have a @value or children |
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. ele-1: All FHIR elements must have a @value or children |
distinctIdentifier | S | 0..1 | string | The distinct identification string ele-1: All FHIR elements must have a @value or children |
manufactureDate | S | 0..1 | dateTime | Date when the device was made ele-1: All FHIR elements must have a @value or children |
expirationDate | S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) ele-1: All FHIR elements must have a @value or children |
lotNumber | S | 0..1 | string | Lot number of manufacture ele-1: All FHIR elements must have a @value or children |
serialNumber | S | 0..1 | string | Serial number assigned by the manufacturer ele-1: All FHIR elements must have a @value or children |
type | S | 1..1 | CodeableConcept | The kind or type of device Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices ele-1: All FHIR elements must have a @value or children |
patient | S | 1..1 | Reference(US Core Patient Profile) | Patient to whom Device is affixed ele-1: All FHIR elements must have a @value or children |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.type | extensible | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | 0..* | Identifier | Instance identifier | |||||
definition | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
udiCarrier | SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
deviceIdentifier | SΣ | 1..1 | string | Mandatory fixed portion of UDI | ||||
issuer | 0..1 | uri | UDI Issuing Organization | |||||
jurisdiction | 0..1 | uri | Regional UDI authority | |||||
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
carrierHRF | SΣ | 0..1 | string | UDI Human Readable Barcode String | ||||
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
distinctIdentifier | S | 0..1 | string | The distinct identification string | ||||
manufacturer | 0..1 | string | Name of device manufacturer | |||||
manufactureDate | S | 0..1 | dateTime | Date when the device was made | ||||
expirationDate | S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | ||||
lotNumber | S | 0..1 | string | Lot number of manufacture | ||||
serialNumber | S | 0..1 | string | Serial number assigned by the manufacturer | ||||
deviceName | 0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
name | 1..1 | string | The name of the device | |||||
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
modelNumber | 0..1 | string | The model number for the device | |||||
partNumber | 0..1 | string | The part number of the device | |||||
type | S | 1..1 | CodeableConcept | The kind or type of device Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices | ||||
specialization | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 0..1 | CodeableConcept | The type of the device version | |||||
component | 0..1 | Identifier | A single component of the device version | |||||
value | 1..1 | string | The version text | |||||
property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
patient | S | 1..1 | Reference(US Core Patient Profile) | Patient to whom Device is affixed | ||||
owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||
contact | 0..* | ContactPoint | Details for human/organization for support | |||||
location | 0..1 | Reference(Location) | Where the device is found | |||||
url | 0..1 | uri | Network address to contact device | |||||
note | 0..* | Annotation | Device notes and comments | |||||
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
parent | 0..1 | Reference(Device) | The parent device | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Device.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages from the FHIR Standard
| ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | extensible | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard |
Differential View
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |
udiCarrier | S | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
deviceIdentifier | S | 1..1 | string | Mandatory fixed portion of UDI |
carrierHRF | S | 0..1 | string | UDI Human Readable Barcode String |
distinctIdentifier | S | 0..1 | string | The distinct identification string |
manufactureDate | S | 0..1 | dateTime | Date when the device was made |
expirationDate | S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) |
lotNumber | S | 0..1 | string | Lot number of manufacture |
serialNumber | S | 0..1 | string | Serial number assigned by the manufacturer |
type | S | 1..1 | CodeableConcept | The kind or type of device Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices |
patient | S | 1..1 | Reference(US Core Patient Profile) | Patient to whom Device is affixed |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.type | extensible | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
udiCarrier | SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string ele-1: All FHIR elements must have a @value or children |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
deviceIdentifier | SΣ | 1..1 | string | Mandatory fixed portion of UDI ele-1: All FHIR elements must have a @value or children |
carrierHRF | SΣ | 0..1 | string | UDI Human Readable Barcode String ele-1: All FHIR elements must have a @value or children |
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. ele-1: All FHIR elements must have a @value or children |
distinctIdentifier | S | 0..1 | string | The distinct identification string ele-1: All FHIR elements must have a @value or children |
manufactureDate | S | 0..1 | dateTime | Date when the device was made ele-1: All FHIR elements must have a @value or children |
expirationDate | S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) ele-1: All FHIR elements must have a @value or children |
lotNumber | S | 0..1 | string | Lot number of manufacture ele-1: All FHIR elements must have a @value or children |
serialNumber | S | 0..1 | string | Serial number assigned by the manufacturer ele-1: All FHIR elements must have a @value or children |
type | S | 1..1 | CodeableConcept | The kind or type of device Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices ele-1: All FHIR elements must have a @value or children |
patient | S | 1..1 | Reference(US Core Patient Profile) | Patient to whom Device is affixed ele-1: All FHIR elements must have a @value or children |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.type | extensible | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | 0..* | Identifier | Instance identifier | |||||
definition | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
udiCarrier | SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
deviceIdentifier | SΣ | 1..1 | string | Mandatory fixed portion of UDI | ||||
issuer | 0..1 | uri | UDI Issuing Organization | |||||
jurisdiction | 0..1 | uri | Regional UDI authority | |||||
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
carrierHRF | SΣ | 0..1 | string | UDI Human Readable Barcode String | ||||
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
distinctIdentifier | S | 0..1 | string | The distinct identification string | ||||
manufacturer | 0..1 | string | Name of device manufacturer | |||||
manufactureDate | S | 0..1 | dateTime | Date when the device was made | ||||
expirationDate | S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | ||||
lotNumber | S | 0..1 | string | Lot number of manufacture | ||||
serialNumber | S | 0..1 | string | Serial number assigned by the manufacturer | ||||
deviceName | 0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
name | 1..1 | string | The name of the device | |||||
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
modelNumber | 0..1 | string | The model number for the device | |||||
partNumber | 0..1 | string | The part number of the device | |||||
type | S | 1..1 | CodeableConcept | The kind or type of device Binding: FHIRDeviceTypes (extensible): Codes to identify medical devices | ||||
specialization | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 0..1 | CodeableConcept | The type of the device version | |||||
component | 0..1 | Identifier | A single component of the device version | |||||
value | 1..1 | string | The version text | |||||
property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
patient | S | 1..1 | Reference(US Core Patient Profile) | Patient to whom Device is affixed | ||||
owner | 0..1 | Reference(Organization) | Organization responsible for device | |||||
contact | 0..* | ContactPoint | Details for human/organization for support | |||||
location | 0..1 | Reference(Location) | Where the device is found | |||||
url | 0..1 | uri | Network address to contact device | |||||
note | 0..* | Annotation | Device notes and comments | |||||
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
parent | 0..1 | Reference(Device) | The parent device | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Device.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages from the FHIR Standard
| ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | extensible | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard |
Other representations of profile: CSV, Excel, Schematron
Below is an overview of the required Server RESTful FHIR interactions for this profile - for example, search and read operations - when supporting the US Core interactions to access this profile's information (Profile Support + Interaction Support). Note that systems that support only US Core Profiles (Profile Only Support) are not required to support these interactions. See the US Core Server CapabilityStatement for a complete list of supported RESTful interactions for this IG.
Servers providing access to implantable device data SHALL support these US Core SMART Scopes:
<patient|user|system>/Device.rs
SHALL support searching for all devices for a patient, including implantable devices using the patient
search parameter:
GET [base]/Device?patient={Type/}[id]
Example:
Implementation Notes: Fetches a bundle of all Device resources for the specified patient (how to search by reference)
The following search parameter combinations SHOULD be supported:
SHOULD support searching using the combination of the patient
and type
search parameters:
GET [base]/Device?patient={Type/}[id]&type={system|}[code]
Example:
Implementation Notes: Fetches a bundle of all Device resources for the specified patient and type. (how to search by reference and how to search by token)
SHOULD support searching using the combination of the patient
and status
search parameters:
status
(e.g.status={system|}[code],{system|}[code],...
)GET [base]/Device?patient={Type/}[id]&status={system|}[code]{,{system|}[code],...}
Example:
Implementation Notes: Fetches a bundle of all Device resources for the specified patient and status (how to search by reference and how to search by token)