Summary
Must-Support: 7 elements
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
This structure is derived from DeviceUseRequest.
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseRequest | 0..* | DeviceUseRequest | ||
bodySite[x] | S | 0..1 | CodeableConcept, Reference(QICore-BodySite) | Binding: SNOMED CT Body Structures (example) |
status | S | 0..1 | code | |
device | S | 1..1 | Reference(QICore-Device) | |
encounter | S | 0..1 | Reference(QICore-Encounter) | |
indication | 0..* | CodeableConcept | Binding: Problem Value Set (preferred) | |
prnReason | 0..* | CodeableConcept | Binding: Problem Value Set (preferred) | |
orderedOn | S | 0..1 | dateTime | |
recordedOn | S | 0..1 | dateTime | |
subject | S | 1..1 | Reference(QICore-Patient) | |
timing[x] | 0..1 | Timing, Period, dateTime | ||
deviceuserequest-reasonRejected | 0..1 | CodeableConcept | If request was rejected, why? URL: http://hl7.org/fhir/StructureDefinition/deviceuserequest-reasonRejected Slice: Unordered, Open, by url Binding: Reasons for rejecting device use request codes (example) | |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseRequest | ∑ | 0..* | DeviceUseRequest | A request for a patient to use or be given a medical device |
meta | ∑ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?! ∑ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: IETF BCP-47 (required) | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
deviceuserequest-reasonRejected | 0..1 | CodeableConcept | Extension URL: http://hl7.org/fhir/StructureDefinition/deviceuserequest-reasonRejected Binding: Reasons for rejecting device use request codes (example) | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
bodySite[x] | S ∑ | 0..1 | CodeableConcept, Reference(QICore-BodySite) | Target body site Binding: SNOMED CT Body Structures (example) |
status | ?! S∑ | 0..1 | code | proposed | planned | requested | received | accepted | in-progress | completed | suspended | rejected | aborted Binding: DeviceUseRequestStatus (required) |
device | S ∑ | 1..1 | Reference(QICore-Device) | Device requested |
encounter | S ∑ | 0..1 | Reference(QICore-Encounter) | Encounter motivating request |
identifier | ∑ | 0..* | Identifier | Request identifier |
indication | ∑ | 0..* | CodeableConcept | Reason for request Binding: Problem Value Set (preferred) |
notes | ∑ | 0..* | string | Notes or comments |
prnReason | ∑ | 0..* | CodeableConcept | PRN Binding: Problem Value Set (preferred) |
orderedOn | S ∑ | 0..1 | dateTime | When ordered |
recordedOn | S ∑ | 0..1 | dateTime | When recorded |
subject | S ∑ | 1..1 | Reference(QICore-Patient) | Focus of request |
timing[x] | ∑ | 0..1 | Timing, Period, dateTime | Schedule for use |
priority | ∑ | 0..1 | code | routine | urgent | stat | asap Binding: DeviceUseRequestPriority (required) |
Documentation for this format |
todo
This structure is derived from DeviceUseRequest.
Summary
Must-Support: 7 elements
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Differential View
This structure is derived from DeviceUseRequest.
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseRequest | 0..* | DeviceUseRequest | ||
bodySite[x] | S | 0..1 | CodeableConcept, Reference(QICore-BodySite) | Binding: SNOMED CT Body Structures (example) |
status | S | 0..1 | code | |
device | S | 1..1 | Reference(QICore-Device) | |
encounter | S | 0..1 | Reference(QICore-Encounter) | |
indication | 0..* | CodeableConcept | Binding: Problem Value Set (preferred) | |
prnReason | 0..* | CodeableConcept | Binding: Problem Value Set (preferred) | |
orderedOn | S | 0..1 | dateTime | |
recordedOn | S | 0..1 | dateTime | |
subject | S | 1..1 | Reference(QICore-Patient) | |
timing[x] | 0..1 | Timing, Period, dateTime | ||
deviceuserequest-reasonRejected | 0..1 | CodeableConcept | If request was rejected, why? URL: http://hl7.org/fhir/StructureDefinition/deviceuserequest-reasonRejected Slice: Unordered, Open, by url Binding: Reasons for rejecting device use request codes (example) | |
Documentation for this format |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceUseRequest | ∑ | 0..* | DeviceUseRequest | A request for a patient to use or be given a medical device |
meta | ∑ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?! ∑ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: IETF BCP-47 (required) | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
deviceuserequest-reasonRejected | 0..1 | CodeableConcept | Extension URL: http://hl7.org/fhir/StructureDefinition/deviceuserequest-reasonRejected Binding: Reasons for rejecting device use request codes (example) | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
bodySite[x] | S ∑ | 0..1 | CodeableConcept, Reference(QICore-BodySite) | Target body site Binding: SNOMED CT Body Structures (example) |
status | ?! S∑ | 0..1 | code | proposed | planned | requested | received | accepted | in-progress | completed | suspended | rejected | aborted Binding: DeviceUseRequestStatus (required) |
device | S ∑ | 1..1 | Reference(QICore-Device) | Device requested |
encounter | S ∑ | 0..1 | Reference(QICore-Encounter) | Encounter motivating request |
identifier | ∑ | 0..* | Identifier | Request identifier |
indication | ∑ | 0..* | CodeableConcept | Reason for request Binding: Problem Value Set (preferred) |
notes | ∑ | 0..* | string | Notes or comments |
prnReason | ∑ | 0..* | CodeableConcept | PRN Binding: Problem Value Set (preferred) |
orderedOn | S ∑ | 0..1 | dateTime | When ordered |
recordedOn | S ∑ | 0..1 | dateTime | When recorded |
subject | S ∑ | 1..1 | Reference(QICore-Patient) | Focus of request |
timing[x] | ∑ | 0..1 | Timing, Period, dateTime | Schedule for use |
priority | ∑ | 0..1 | code | routine | urgent | stat | asap Binding: DeviceUseRequestPriority (required) |
Documentation for this format |
XML Template
JSON Template
todo
Other representations of profile: Schematron
Path | Name | Conformance | ValueSet |
DeviceUseRequest.language | ?ext | required | http://tools.ietf.org/html/bcp47 |
DeviceUseRequest.extension [UriType[http://hl7.org/fhir/StructureDefinition/deviceuserequest-reasonRejected]] | Reasons for rejecting device use request codes | example | Reasons for rejecting device use request codes |
DeviceUseRequest.bodySite[x] | SNOMED CT Body Structures | example | SNOMED CT Body Structures |
DeviceUseRequest.status | DeviceUseRequestStatus | required | DeviceUseRequestStatus |
DeviceUseRequest.indication | Problem Value Set | preferred | Problem Value Set |
DeviceUseRequest.prnReason | Problem Value Set | preferred | Problem Value Set |
DeviceUseRequest.priority | DeviceUseRequestPriority | required | DeviceUseRequestPriority |
Id | Path | Details | Requirements |