HL7 Cross Paradigm Implementation Guide: Gender Harmony - Sex and Gender Representation, Edition 1
1.0.0 - release

This page is part of the HL7 Cross Paradigm IG: Gender Harmony - Sex and Gender Representation (v1.0.0: informative1 - Informative) based on FHIR v5.0.0. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

Terminology

Words are singularly the most powerful force available to humanity. We can choose to use this force constructively with words of encouragement, or destructively using words of despair. Words have energy and power with the ability to help, to heal, to hinder, to hurt, to harm, to humiliate and to humble.

-Yehuda Berg

General

Medical terminology and standards, as core parts of medical systems, are necessarily omnipresent in today’s biomedical landscape. They form an important cornerstone of almost all digital health technology utilized today around the world. However, despite their increasing importance to health care, medical terminology and standards rarely consider the ethical implications surrounding their existence. Many communities have been adversely affected by this lack of consideration, which this guide hopes to address in part by careful consideration to the terminology used when representing sex and gender in clinical systems. The initial Gender Harmony logical model publication provides an in-depth discussion on issues regarding clinical sex and gender terminology, as does the JAMIA publication “Gender harmony: improved standards to support affirmative care of gender-marginalized people through inclusive gender and sex representation” and we refer the interested reader to those documents for useful background.

A primary objective of this project is to create and collect terminology that will be used for the same purpose, within aligned models across all HL7 product families, and through that example, within non-HL7 standards as well. To meet that goal we have created value sets using well-known existing available code system standards that are freely available for use. Where this is not possible this guide includes new code systems that will be maintained by HL7. All value sets and code systems defined by the Gender Harmony project will be published at the primary HL7-wide terminology publication found at terminology.hl7.org (known as THO.)

As an international standard, the Gender Harmony terminology is mostly focused on defining minimum required value sets. This means that implementers need to pay attention to the binding strength used when binding the value set noted. In most cases the value set will be bound Extensible (which in CDA would be SHOULD) which means that the values provided are to be used when sending information that is scoped or means the same as the values provided. It is very important to understand that only when the binding is Required (SHALL in CDA) are the values provided in the bound value set the only set to be used where one of the provided set MUST be sent (additional values can also be sent, but one from the value set needs to be included.) This means that for any binding other than Required, the concepts, codes, and even text that are not included in the defined value set may be sent instead. This guide assumes that jurisdictions will build upon the minimum set included in the defined value sets to produce operational value sets to be noted in jurisdictional guides or regulations. It is also noted that only text or codes from other code systems may be sent in conformant exchange when the value set is not bound Required.

For all value sets bound EXTENSIBLE or PREFERRED, implementers are discouraged from mapping to one of the included concepts other codes that do not exactly match in meaning. By this we mean that if a patient uses some other word, or concept, to represent the exchanged information, such as gender identity of “non-conforming”, the instance would consider this an additional concept that could be considered acceptable. In this case the instance would include the additional text or concept as the CodableConcept value and not also “roll-up” to a code provided in the minimum set. Meanings in these domains can overlap and yet should always be considered distinct.

Gender Identity terminology (GI)

There are two different terminologies that are relevant for gender identity. The LOINC code 76691-5 identities the Gender Identity concept itself, while a value set using SNOMED codes can be used to represent the gender identities.

The gender identity value set in this guide is intended to be a minimum value set of commonly used values and it is expected and encouraged that specific jurisdictions or communities will use additional gender identity concepts that are relevant within their community. For example, in the United States, two-spirit may be included in the value set, while in South Asia, hijra may be included. The gender identity minimum value set is built using concepts from the SNOMED CT International edition code system. SNOMED International has put significant effort into improving the representation of gender concepts and while that work is not complete, the concepts included in the gender identity value set represent affirming and useful representations of gender concepts. In addition the value set includes the HL7 null flavor UNK to be used if the gender is not known. We encourage comments on the use of the null flavor code system in this situation versus the Data Absent Reason (DAR) code system used in FHIR. Of particular interest is the difficulty for implementers moving from prior use of null flavor value sets to DAR.

Please note that CDA requires the use of value sets that do not include null flavor concepts, therefore the CDA entry templates bind to a separate “core” value set of SNOMED CT concepts, and that value set is used to build the overall gender identity minimum value set.

Sex Parameter For Clinial Use (SPCU)

As noted in our JAMIA publication

SPCU (previously SFCU) is a summary sex classification element based on one or more clinical observations such as an organ survey, hormone levels, and chromosomal analysis. SPCU can provide a “patient-level” summary clinical sex characterization value to be specified for any clinical order, result, or assessment. SPCU also allows users to specify different values for the same patient for specific clinical uses.

SPCU is intended as a replacement for the idea of “clinical sex” which most importantly brings a context-specific focus to the use of the SPCU value exchanged. The value provided is not a general, use anywhere value. Provision of “a clinical sex in all uses” has been found to be dangerously over-simplified. The SPCU exchange element exists to help align current system expectations for sex-classification reference ranges or system set-up settings to fill the gap between defined sex-characteristic aligned clinical observations that influence those settings, and the operational need to put in a binary sex value. In cases that need a sex-category to do a procedure or report a result, SPCU provides a method to exchange the needed summary sex classification value, along with the specific clinical observation used to determine the SPCU value. In addition to Male-typical or Female-typical, SPCU also provides an important additional value of Specified which is an indication that additional information should be available, or obtained from the patient/record to clarify any specific clinical information needed to make the clinical sex-related decision.

Because the three included values scope all possible values (plus a SPCU-specific unknown), the value set is bound REQUIRED/SHALL and only the values included are allowed.

The code system used for this value set is the internal HL7 code system Sex For Clinical Use.

The Sex For Clinical Use value set is defined as part of the R5 FHIR Specification.

The LOINC code for the “observable encoding” of the Sex For Clinical Use is 99501-9

Pronouns

Pronouns are an important aspect of identity reference in many languages, and when used are often aligned with gender differences. The Gender Harmony project includes a minimal set of English language third-person personal pronouns as used by a person to enable affirming interactions during patient care. The provided minimal pronoun set is defined as a set of personal pronouns (subject and object pronouns) and their respective possessive pronoun(s), reflexive pronoun(s), and possessive determiner(s) (colloquially referred to as “possessive adjectives”). These values are specified by the patient for use in healthcare interactions, clinical notes, and in written instructions to caregivers. As is true of the other minimal value sets, those provided are to enable common exchange covering most of the need but are not a complete set and many patients will desire pronouns that are not included in this value set. Jurisdictions and regulators are strongly encouraged to add additional values to this minimal set. As is true for Gender Identity, overlapping sets are common but always distinct.

The set chosen for this value set are derived from LOINC code system and are based upon the Answer List for the LOINC code 90778-2 “Personal pronouns - Reported”

The Pronouns value set is defined in THO.

The LOINC code for the “observable encoding” of the Personal pronouns - Reported is 90778-2

Recorded Sex or Gender (RSG)

The RSG element is intended to support the exchange of any sex or gender recorded data that is not specifically known to be the gender identity or a needed SPCU. The element allows any code or text that is in the record to be sent as the “recorded value” so no value set or code system is defined for that element. We do provide a value set and use an external code system for sending an international equivalent value in addition to the actual recorded value.

When exchanging a Recorded Sex or Gender concept, it is expected that there are existing value sets that can be used. For example, when using Recorded Sex or Gender to exchange Sex Assigned at Birth, a jurisdiction may have an existing value set for Sex Assigned at Birth, which would be used to exchange the value for the Sex Assigned at Birth as a Recorded Sex or Gender.

The Recorded Sex or Gender value set is defined in THO.

The LOINC code for the “observable encoding” of the Recorded Sex or Gender is 99502-7

Name to Use (NtU)

The name that should be used when addressing a person does not require any new terminology. Each HL7 product family already has a defined approach that can support this in exchanges. The Gender Harmony model only specifies how to do this in each family. For example in the FHIR specification, the HumanName datatype would represent this with humanName.use = “usual”.