Extensions for Using Data Elements from FHIR R5 in FHIR R4 - Downloaded Version null See the Directory of published versions
| Official URL: http://hl7.org/fhir/5.0/StructureDefinition/profile-DeviceAssociation-for-Device | Version: 0.1.0 | |||
| Standards status: Trial-use | Maturity Level: 0 | Computable Name: Profile_R5_DeviceAssociation_R4_Device | ||
This cross-version profile allows R5 DeviceAssociation content to be represented via FHIR R4 Device resources.
Usages:
You can also check for usages in the FHIR IG Statistics
Description of Profiles, Differentials, Snapshots and how the different presentations work.
| Path | Status | Usage | ValueSet | Version | Source |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | Device.implicitRules, Device.extension, Device.extension:device, Device.extension:category, Device.extension:status, Device.extension:bodyStructure, Device.extension:period, Device.extension:operation, Device.modifierExtension, Device.status | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | Device.extension, Device.extension:device, Device.extension:category, Device.extension:status, Device.extension:bodyStructure, Device.extension:period, Device.extension:operation, Device.modifierExtension | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
This structure is derived from Device
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
0..* | Device(4.0.1) | Item used in healthcare | |||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
2..* | Extension | Extension Slice: Unordered, Open by value:url Constraints: ext-1 | |||||
![]() ![]() ![]() |
1..1 | Reference(Cross-version Profile for R5.Device for use in FHIR R4(0.1.0) | Device) | R5: Reference to the devices associated with the patient or group (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.device Constraints: ext-1 | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | R5: Describes the relationship between the device and subject (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.category Constraints: ext-1 | |||||
![]() ![]() ![]() |
1..1 | CodeableConcept | R5: implanted | explanted | attached | entered-in-error | unknown (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.status Binding: R5DeviceassociationStatusForR4 (0.1.0) (required): Describes the lifecycle of the association. Constraints: ext-1 | |||||
![]() ![]() ![]() |
0..1 | Reference(Cross-version Profile for R5.BodyStructure for use in FHIR R4(0.1.0) | BodyStructure) | R5: Current anatomical location of the device in/on subject (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.bodyStructure Constraints: ext-1 | |||||
![]() ![]() ![]() |
0..1 | Period | R5: Begin and end dates and times for the device association (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.period Constraints: ext-1 | |||||
![]() ![]() ![]() |
0..* | (Complex) | R5: The details about the device when it is in use to describe its operation (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.operation Constraints: ext-1 | |||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored Constraints: ext-1 | ||||
![]() ![]() |
0..* | Identifier | Instance identifier | |||||
![]() ![]() |
0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
![]() ![]() |
Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||
![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||
![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url Constraints: ext-1 | |||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | R5: The reasons given for the current association status URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.statusReason Binding: R5DeviceassociationStatusReasonForR4 (0.1.0) (required): Describes the reason for changing the status of the association. Constraints: ext-1 | |||||
![]() ![]() ![]() |
Σ | 0..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
0..1 | string | The distinct identification string | |||||
![]() ![]() |
0..1 | string | Name of device manufacturer | |||||
![]() ![]() |
0..1 | dateTime | Date when the device was made | |||||
![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
![]() ![]() |
0..1 | string | Lot number of manufacture | |||||
![]() ![]() |
0..1 | string | Serial number assigned by the manufacturer | |||||
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
![]() ![]() |
0..1 | string | The model number for the device | |||||
![]() ![]() |
0..1 | string | The part number of the device | |||||
![]() ![]() |
0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices. | |||||
![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | |||||
![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | |||||
![]() ![]() ![]() |
1..1 | string | The version text | |||||
![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() |
0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url Constraints: ext-1 | |||||
![]() ![]() ![]() ![]() |
0..1 | Reference(Resource) | R5: The individual, group of individuals or device that the device is on or associated with URL: http://hl7.org/fhir/StructureDefinition/alternate-reference Constraints: ext-1 | |||||
![]() ![]() ![]() |
ΣC | 0..1 | string | Literal reference, Relative, internal or absolute URL | ||||
![]() ![]() ![]() |
Σ | 0..1 | uri | Type the reference refers to (e.g. "Patient") Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model). | ||||
![]() ![]() ![]() |
Σ | 0..1 | Identifier | Logical reference, when literal reference is not known | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Text alternative for the resource | ||||
![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||
![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() |
0..1 | Reference(Location) | Where the device is found | |||||
![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
![]() ![]() |
0..1 | Reference(Device) | The parent device | |||||
Documentation for this format | ||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.language | Base | preferred |
Common Languages
|
📍4.0.1 | tx.fhir.org |
| Device.udiCarrier.entryType | Base | required |
UDIEntryType
|
📍4.0.1 | tx.fhir.org |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.statusReason | Base | extensible | FHIRDeviceStatusReason | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | example | Device Type | 📍4.0.1 | FHIR Std. |
| Device.patient.type | Base | extensible |
ResourceType
|
📍4.0.1 | tx.fhir.org |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | Device.meta, Device.implicitRules, Device.language, Device.text, Device.extension, Device.extension:device, Device.extension:category, Device.extension:status, Device.extension:bodyStructure, Device.extension:period, Device.extension:operation, Device.modifierExtension, Device.identifier, Device.definition, Device.udiCarrier, Device.udiCarrier.extension, Device.udiCarrier.modifierExtension, Device.udiCarrier.deviceIdentifier, Device.udiCarrier.issuer, Device.udiCarrier.jurisdiction, Device.udiCarrier.carrierAIDC, Device.udiCarrier.carrierHRF, Device.udiCarrier.entryType, Device.status, Device.statusReason, Device.statusReason.extension, Device.statusReason.extension:statusReason, Device.statusReason.coding, Device.statusReason.text, Device.distinctIdentifier, Device.manufacturer, Device.manufactureDate, Device.expirationDate, Device.lotNumber, Device.serialNumber, Device.deviceName, Device.deviceName.extension, Device.deviceName.modifierExtension, Device.deviceName.name, Device.deviceName.type, Device.modelNumber, Device.partNumber, Device.type, Device.specialization, Device.specialization.extension, Device.specialization.modifierExtension, Device.specialization.systemType, Device.specialization.version, Device.version, Device.version.extension, Device.version.modifierExtension, Device.version.type, Device.version.component, Device.version.value, Device.property, Device.property.extension, Device.property.modifierExtension, Device.property.type, Device.property.valueQuantity, Device.property.valueCode, Device.patient, Device.patient.extension, Device.patient.extension:subject, Device.patient.reference, Device.patient.type, Device.patient.identifier, Device.patient.display, Device.owner, Device.contact, Device.location, Device.url, Device.note, Device.safety, Device.parent | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | Device.extension, Device.extension:device, Device.extension:category, Device.extension:status, Device.extension:bodyStructure, Device.extension:period, Device.extension:operation, Device.modifierExtension, Device.udiCarrier.extension, Device.udiCarrier.modifierExtension, Device.statusReason.extension, Device.statusReason.extension:statusReason, Device.deviceName.extension, Device.deviceName.modifierExtension, Device.specialization.extension, Device.specialization.modifierExtension, Device.version.extension, Device.version.modifierExtension, Device.property.extension, Device.property.modifierExtension, Device.patient.extension, Device.patient.extension:subject | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
This structure is derived from Device
Summary
Mandatory: 2 elements
Extensions
This structure refers to these extensions:
Maturity: 0
Key Elements View
| Path | Status | Usage | ValueSet | Version | Source |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | Device.implicitRules, Device.extension, Device.extension:device, Device.extension:category, Device.extension:status, Device.extension:bodyStructure, Device.extension:period, Device.extension:operation, Device.modifierExtension, Device.status | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | Device.extension, Device.extension:device, Device.extension:category, Device.extension:status, Device.extension:bodyStructure, Device.extension:period, Device.extension:operation, Device.modifierExtension | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Differential View
This structure is derived from Device
Snapshot View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
0..* | Device(4.0.1) | Item used in healthcare | |||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
2..* | Extension | Extension Slice: Unordered, Open by value:url Constraints: ext-1 | |||||
![]() ![]() ![]() |
1..1 | Reference(Cross-version Profile for R5.Device for use in FHIR R4(0.1.0) | Device) | R5: Reference to the devices associated with the patient or group (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.device Constraints: ext-1 | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | R5: Describes the relationship between the device and subject (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.category Constraints: ext-1 | |||||
![]() ![]() ![]() |
1..1 | CodeableConcept | R5: implanted | explanted | attached | entered-in-error | unknown (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.status Binding: R5DeviceassociationStatusForR4 (0.1.0) (required): Describes the lifecycle of the association. Constraints: ext-1 | |||||
![]() ![]() ![]() |
0..1 | Reference(Cross-version Profile for R5.BodyStructure for use in FHIR R4(0.1.0) | BodyStructure) | R5: Current anatomical location of the device in/on subject (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.bodyStructure Constraints: ext-1 | |||||
![]() ![]() ![]() |
0..1 | Period | R5: Begin and end dates and times for the device association (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.period Constraints: ext-1 | |||||
![]() ![]() ![]() |
0..* | (Complex) | R5: The details about the device when it is in use to describe its operation (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.operation Constraints: ext-1 | |||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored Constraints: ext-1 | ||||
![]() ![]() |
0..* | Identifier | Instance identifier | |||||
![]() ![]() |
0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
![]() ![]() |
Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||
![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||
![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url Constraints: ext-1 | |||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | R5: The reasons given for the current association status URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceAssociation.statusReason Binding: R5DeviceassociationStatusReasonForR4 (0.1.0) (required): Describes the reason for changing the status of the association. Constraints: ext-1 | |||||
![]() ![]() ![]() |
Σ | 0..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
0..1 | string | The distinct identification string | |||||
![]() ![]() |
0..1 | string | Name of device manufacturer | |||||
![]() ![]() |
0..1 | dateTime | Date when the device was made | |||||
![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
![]() ![]() |
0..1 | string | Lot number of manufacture | |||||
![]() ![]() |
0..1 | string | Serial number assigned by the manufacturer | |||||
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
![]() ![]() |
0..1 | string | The model number for the device | |||||
![]() ![]() |
0..1 | string | The part number of the device | |||||
![]() ![]() |
0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices. | |||||
![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | |||||
![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | |||||
![]() ![]() ![]() |
1..1 | string | The version text | |||||
![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() |
0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url Constraints: ext-1 | |||||
![]() ![]() ![]() ![]() |
0..1 | Reference(Resource) | R5: The individual, group of individuals or device that the device is on or associated with URL: http://hl7.org/fhir/StructureDefinition/alternate-reference Constraints: ext-1 | |||||
![]() ![]() ![]() |
ΣC | 0..1 | string | Literal reference, Relative, internal or absolute URL | ||||
![]() ![]() ![]() |
Σ | 0..1 | uri | Type the reference refers to (e.g. "Patient") Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model). | ||||
![]() ![]() ![]() |
Σ | 0..1 | Identifier | Logical reference, when literal reference is not known | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Text alternative for the resource | ||||
![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||
![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() |
0..1 | Reference(Location) | Where the device is found | |||||
![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
![]() ![]() |
0..1 | Reference(Device) | The parent device | |||||
Documentation for this format | ||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.language | Base | preferred |
Common Languages
|
📍4.0.1 | tx.fhir.org |
| Device.udiCarrier.entryType | Base | required |
UDIEntryType
|
📍4.0.1 | tx.fhir.org |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.statusReason | Base | extensible | FHIRDeviceStatusReason | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | example | Device Type | 📍4.0.1 | FHIR Std. |
| Device.patient.type | Base | extensible |
ResourceType
|
📍4.0.1 | tx.fhir.org |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | Device.meta, Device.implicitRules, Device.language, Device.text, Device.extension, Device.extension:device, Device.extension:category, Device.extension:status, Device.extension:bodyStructure, Device.extension:period, Device.extension:operation, Device.modifierExtension, Device.identifier, Device.definition, Device.udiCarrier, Device.udiCarrier.extension, Device.udiCarrier.modifierExtension, Device.udiCarrier.deviceIdentifier, Device.udiCarrier.issuer, Device.udiCarrier.jurisdiction, Device.udiCarrier.carrierAIDC, Device.udiCarrier.carrierHRF, Device.udiCarrier.entryType, Device.status, Device.statusReason, Device.statusReason.extension, Device.statusReason.extension:statusReason, Device.statusReason.coding, Device.statusReason.text, Device.distinctIdentifier, Device.manufacturer, Device.manufactureDate, Device.expirationDate, Device.lotNumber, Device.serialNumber, Device.deviceName, Device.deviceName.extension, Device.deviceName.modifierExtension, Device.deviceName.name, Device.deviceName.type, Device.modelNumber, Device.partNumber, Device.type, Device.specialization, Device.specialization.extension, Device.specialization.modifierExtension, Device.specialization.systemType, Device.specialization.version, Device.version, Device.version.extension, Device.version.modifierExtension, Device.version.type, Device.version.component, Device.version.value, Device.property, Device.property.extension, Device.property.modifierExtension, Device.property.type, Device.property.valueQuantity, Device.property.valueCode, Device.patient, Device.patient.extension, Device.patient.extension:subject, Device.patient.reference, Device.patient.type, Device.patient.identifier, Device.patient.display, Device.owner, Device.contact, Device.location, Device.url, Device.note, Device.safety, Device.parent | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | Device.extension, Device.extension:device, Device.extension:category, Device.extension:status, Device.extension:bodyStructure, Device.extension:period, Device.extension:operation, Device.modifierExtension, Device.udiCarrier.extension, Device.udiCarrier.modifierExtension, Device.statusReason.extension, Device.statusReason.extension:statusReason, Device.deviceName.extension, Device.deviceName.modifierExtension, Device.specialization.extension, Device.specialization.modifierExtension, Device.version.extension, Device.version.modifierExtension, Device.property.extension, Device.property.modifierExtension, Device.patient.extension, Device.patient.extension:subject | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
This structure is derived from Device
Summary
Mandatory: 2 elements
Extensions
This structure refers to these extensions:
Maturity: 0
Other representations of profile: CSV, Excel, Schematron