Extensions for Using Data Elements from FHIR R5 in FHIR STU3 - Downloaded Version null See the Directory of published versions
The FHIR R5 resource is represented in FHIR STU3 via the ImagingStudy resource.
Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: ImagingStudy
A computable version of the following element information is available in: R5ImagingStudyElementMapToR3
| Source Element (FHIR R5) | Target(s) | Comments |
|---|---|---|
ImagingStudy |
||
ImagingStudy.meta |
ImagingStudy.meta | Element ImagingStudy.meta is mapped to FHIR STU3 element ImagingStudy.meta as Equivalent. |
ImagingStudy.implicitRules |
ImagingStudy.implicitRules | Element ImagingStudy.implicitRules is mapped to FHIR STU3 element ImagingStudy.implicitRules as Equivalent. |
ImagingStudy.language |
ImagingStudy.language | Element ImagingStudy.language is mapped to FHIR STU3 element ImagingStudy.language as Equivalent. |
ImagingStudy.text |
ImagingStudy.text | Element ImagingStudy.text is mapped to FHIR STU3 element ImagingStudy.text as Equivalent. |
ImagingStudy.contained |
ImagingStudy.contained | Element ImagingStudy.contained is mapped to FHIR STU3 element ImagingStudy.contained as SourceIsBroaderThanTarget. |
ImagingStudy.identifier |
ImagingStudy.accession ImagingStudy.identifier ImagingStudy.uid |
Element ImagingStudy.identifier is mapped to FHIR STU3 element ImagingStudy.uid as SourceIsBroaderThanTarget.Element ImagingStudy.identifier is mapped to FHIR STU3 element ImagingStudy.accession as SourceIsBroaderThanTarget.Element ImagingStudy.identifier is mapped to FHIR STU3 element ImagingStudy.identifier as Equivalent. |
ImagingStudy.status |
ImagingStudy.availability | Element ImagingStudy.status is mapped to FHIR STU3 element ImagingStudy.availability as Equivalent. |
ImagingStudy.modality |
ImagingStudy.modalityList Extension: ExtensionImagingStudy_Modality |
Element ImagingStudy.modality is mapped to FHIR STU3 element ImagingStudy.modalityList as SourceIsBroaderThanTarget.The mappings for ImagingStudy.modality do not cover the following types: CodeableConcept.The mappings for ImagingStudy.modality do not cover the following types based on type expansion: text. |
ImagingStudy.subject |
ImagingStudy.patient Standard Extension: alternate-reference |
Element ImagingStudy.subject is mapped to FHIR STU3 element ImagingStudy.patient as SourceIsBroaderThanTarget.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ImagingStudy.subject with unmapped reference targets: Device, Group, Patient. |
ImagingStudy.encounter |
ImagingStudy.context Standard Extension: alternate-reference |
Element ImagingStudy.encounter is mapped to FHIR STU3 element ImagingStudy.context as SourceIsBroaderThanTarget.The mappings for ImagingStudy.encounter do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ImagingStudy.encounter with unmapped reference targets: Encounter. |
ImagingStudy.started |
ImagingStudy.started | Element ImagingStudy.started is mapped to FHIR STU3 element ImagingStudy.started as Equivalent. |
ImagingStudy.basedOn |
ImagingStudy.basedOn Standard Extension: alternate-reference |
Element ImagingStudy.basedOn is mapped to FHIR STU3 element ImagingStudy.basedOn as SourceIsBroaderThanTarget.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ImagingStudy.basedOn with unmapped reference targets: Appointment, AppointmentResponse, CarePlan, ServiceRequest, Task. |
ImagingStudy.partOf |
Extension: ExtensionImagingStudy_PartOf | Element ImagingStudy.partOf has a context of ImagingStudy based on following the parent source element upwards and mapping to ImagingStudy.Element ImagingStudy.partOf has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingStudy.referrer |
ImagingStudy.referrer Standard Extension: alternate-reference |
Element ImagingStudy.referrer is mapped to FHIR STU3 element ImagingStudy.referrer as SourceIsBroaderThanTarget.The mappings for ImagingStudy.referrer do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ImagingStudy.referrer with unmapped reference targets: Practitioner, PractitionerRole. |
ImagingStudy.endpoint |
ImagingStudy.endpoint Standard Extension: alternate-reference |
Element ImagingStudy.endpoint is mapped to FHIR STU3 element ImagingStudy.endpoint as SourceIsBroaderThanTarget.The mappings for ImagingStudy.endpoint do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ImagingStudy.endpoint with unmapped reference targets: Endpoint. |
ImagingStudy.numberOfSeries |
ImagingStudy.numberOfSeries | Element ImagingStudy.numberOfSeries is mapped to FHIR STU3 element ImagingStudy.numberOfSeries as Equivalent. |
ImagingStudy.numberOfInstances |
ImagingStudy.numberOfInstances | Element ImagingStudy.numberOfInstances is mapped to FHIR STU3 element ImagingStudy.numberOfInstances as Equivalent. |
ImagingStudy.procedure |
ImagingStudy.procedureCode ImagingStudy.procedureReference |
Element ImagingStudy.procedure is mapped to FHIR STU3 element ImagingStudy.procedureReference as RelatedTo.Element ImagingStudy.procedure is mapped to FHIR STU3 element ImagingStudy.procedureCode as SourceIsBroaderThanTarget. |
ImagingStudy.location |
Extension: ExtensionImagingStudy_Location | Element ImagingStudy.location has a context of ImagingStudy based on following the parent source element upwards and mapping to ImagingStudy.Element ImagingStudy.location has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingStudy.reason |
ImagingStudy.reason Extension: ExtensionImagingStudy_Reason |
Element ImagingStudy.reason is mapped to FHIR STU3 element ImagingStudy.reason as SourceIsBroaderThanTarget.The mappings for ImagingStudy.reason do not cover the following types: CodeableReference. |
ImagingStudy.note |
Extension: ExtensionImagingStudy_Note | Element ImagingStudy.note has a context of ImagingStudy based on following the parent source element upwards and mapping to ImagingStudy.Element ImagingStudy.note has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingStudy.description |
ImagingStudy.description | Element ImagingStudy.description is mapped to FHIR STU3 element ImagingStudy.description as Equivalent. |
ImagingStudy.series |
ImagingStudy.series | Element ImagingStudy.series is mapped to FHIR STU3 element ImagingStudy.series as Equivalent. |
ImagingStudy.series.uid |
ImagingStudy.series.uid Extension: ExtensionImagingStudy_Series_Uid |
Element ImagingStudy.series.uid is mapped to FHIR STU3 element ImagingStudy.series.uid as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.uid do not cover the following types: id.The mappings for ImagingStudy.series.uid do not cover the following types based on type expansion: value. |
ImagingStudy.series.number |
ImagingStudy.series.number | Element ImagingStudy.series.number is mapped to FHIR STU3 element ImagingStudy.series.number as Equivalent. |
ImagingStudy.series.modality |
ImagingStudy.series.modality Extension: ExtensionImagingStudy_Series_Modality |
Element ImagingStudy.series.modality is mapped to FHIR STU3 element ImagingStudy.series.modality as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.modality do not cover the following types: CodeableConcept.The mappings for ImagingStudy.series.modality do not cover the following types based on type expansion: text. |
ImagingStudy.series.description |
ImagingStudy.series.description | Element ImagingStudy.series.description is mapped to FHIR STU3 element ImagingStudy.series.description as Equivalent. |
ImagingStudy.series.numberOfInstances |
ImagingStudy.series.numberOfInstances | Element ImagingStudy.series.numberOfInstances is mapped to FHIR STU3 element ImagingStudy.series.numberOfInstances as Equivalent. |
ImagingStudy.series.endpoint |
ImagingStudy.series.endpoint Standard Extension: alternate-reference |
Element ImagingStudy.series.endpoint is mapped to FHIR STU3 element ImagingStudy.series.endpoint as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.endpoint do not cover the following types based on type expansion: display, identifier, reference, type.The standard extension alternate-reference has been mapped as the representation of FHIR R5 element ImagingStudy.series.endpoint with unmapped reference targets: Endpoint. |
ImagingStudy.series.bodySite |
ImagingStudy.series.bodySite Extension: ExtensionImagingStudy_Series_BodySite |
Element ImagingStudy.series.bodySite is mapped to FHIR STU3 element ImagingStudy.series.bodySite as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.bodySite do not cover the following types: CodeableReference.The mappings for ImagingStudy.series.bodySite do not cover the following types based on type expansion: concept, reference. |
ImagingStudy.series.laterality |
ImagingStudy.series.laterality Extension: ExtensionImagingStudy_Series_Laterality |
Element ImagingStudy.series.laterality is mapped to FHIR STU3 element ImagingStudy.series.laterality as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.laterality do not cover the following types: CodeableConcept.The mappings for ImagingStudy.series.laterality do not cover the following types based on type expansion: text. |
ImagingStudy.series.specimen |
Extension: ExtensionImagingStudy_Series_Specimen | Element ImagingStudy.series.specimen has a context of ImagingStudy.series based on following the parent source element upwards and mapping to ImagingStudy.Element ImagingStudy.series.specimen has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingStudy.series.started |
ImagingStudy.series.started | Element ImagingStudy.series.started is mapped to FHIR STU3 element ImagingStudy.series.started as Equivalent. |
ImagingStudy.series.performer |
ImagingStudy.series.performer | Element ImagingStudy.series.performer is mapped to FHIR STU3 element ImagingStudy.series.performer as Equivalent. |
ImagingStudy.series.performer.function |
Extension: ExtensionImagingStudy_Series_Performer_Function | Element ImagingStudy.series.performer.function has a context of ImagingStudy.series.performer based on following the parent source element upwards and mapping to ImagingStudy.Element ImagingStudy.series.performer.function has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingStudy.series.performer.actor |
Extension: ExtensionImagingStudy_Series_Performer_Actor | Element ImagingStudy.series.performer.actor has a context of ImagingStudy.series.performer based on following the parent source element upwards and mapping to ImagingStudy.Element ImagingStudy.series.performer.actor has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingStudy.series.instance |
ImagingStudy.series.instance | Element ImagingStudy.series.instance is mapped to FHIR STU3 element ImagingStudy.series.instance as Equivalent. |
ImagingStudy.series.instance.uid |
ImagingStudy.series.instance.uid Extension: ExtensionImagingStudy_Series_Instance_Uid |
Element ImagingStudy.series.instance.uid is mapped to FHIR STU3 element ImagingStudy.series.instance.uid as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.instance.uid do not cover the following types: id.The mappings for ImagingStudy.series.instance.uid do not cover the following types based on type expansion: value. |
ImagingStudy.series.instance.sopClass |
ImagingStudy.series.instance.sopClass Extension: ExtensionImagingStudy_Series_Instance_SopClass |
Element ImagingStudy.series.instance.sopClass is mapped to FHIR STU3 element ImagingStudy.series.instance.sopClass as SourceIsBroaderThanTarget.The mappings for ImagingStudy.series.instance.sopClass do not cover the following types: Coding.The mappings for ImagingStudy.series.instance.sopClass do not cover the following types based on type expansion: code, display, system, userSelected, version. |
ImagingStudy.series.instance.number |
ImagingStudy.series.instance.number | Element ImagingStudy.series.instance.number is mapped to FHIR STU3 element ImagingStudy.series.instance.number as Equivalent. |
ImagingStudy.series.instance.title |
ImagingStudy.series.instance.title | Element ImagingStudy.series.instance.title is mapped to FHIR STU3 element ImagingStudy.series.instance.title as Equivalent. |