Extensions for Using Data Elements from FHIR R5 in FHIR STU3 - Downloaded Version null See the Directory of published versions
The FHIR R5 resource is represented in FHIR STU3 via the Basic resource.
Note that there is a profile defined to simplify use of this cross-version resource representation:Profile: ImagingSelection
A computable version of the following element information is available in: R5ImagingSelectionElementMapToR3
| Source Element (FHIR R5) | Target(s) | Comments |
|---|---|---|
ImagingSelection |
||
ImagingSelection.meta |
Basic.meta | Element matches Basic element path Basic.meta (Resource.meta), use that element instead.Element ImagingSelection.meta is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.meta has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.implicitRules |
Basic.implicitRules | Element matches Basic element path Basic.implicitRules (Resource.implicitRules), use that element instead.Element ImagingSelection.implicitRules is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.implicitRules has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.language |
Basic.language | Element matches Basic element path Basic.language (Resource.language), use that element instead.Element ImagingSelection.language is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.language has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.text |
Basic.text | Element matches Basic element path Basic.text (DomainResource.text), use that element instead.Element ImagingSelection.text is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.text has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.contained |
Basic.contained | Element matches Basic element path Basic.contained (DomainResource.contained), use that element instead.Element ImagingSelection.contained is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.contained has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.identifier |
Basic.identifier | Element matches Basic element path Basic.identifier (Basic.identifier), use that element instead.Element ImagingSelection.identifier is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.identifier has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.status |
Modifier Extension: ExtensionImagingSelection_Status | Element ImagingSelection.status is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.status has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.subject |
Basic.subject | Element matches Basic element path Basic.subject (Basic.subject), use that element instead.Element ImagingSelection.subject is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.subject has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.issued |
Extension: ExtensionImagingSelection_Issued | Element ImagingSelection.issued is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.issued has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.performer |
Extension: ExtensionImagingSelection_Performer | Element ImagingSelection.performer is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.performer has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.performer.function |
Extension: ExtensionImagingSelection_Performer Slice:function | Element ImagingSelection.performer.function is part of an existing definition because parent element ImagingSelection.performer requires a cross-version extension.Element ImagingSelection.performer.function is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.performer.function has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.performer.actor |
Extension: ExtensionImagingSelection_Performer Slice:actor | Element ImagingSelection.performer.actor is part of an existing definition because parent element ImagingSelection.performer requires a cross-version extension.Element ImagingSelection.performer.actor is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.performer.actor has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.basedOn |
Extension: ExtensionImagingSelection_BasedOn | Element ImagingSelection.basedOn is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.basedOn has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.category |
Extension: ExtensionImagingSelection_Category | Element ImagingSelection.category is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.category has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.code |
Extension: ExtensionImagingSelection_Code | Element ImagingSelection.code is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.code has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.studyUid |
Extension: ExtensionImagingSelection_StudyUid | Element ImagingSelection.studyUid is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.studyUid has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.derivedFrom |
Extension: ExtensionImagingSelection_DerivedFrom | Element ImagingSelection.derivedFrom is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.derivedFrom has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.endpoint |
Extension: ExtensionImagingSelection_Endpoint | Element ImagingSelection.endpoint is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.endpoint has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.seriesUid |
Extension: ExtensionImagingSelection_SeriesUid | Element ImagingSelection.seriesUid is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.seriesUid has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.seriesNumber |
Extension: ExtensionImagingSelection_SeriesNumber | Element ImagingSelection.seriesNumber is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.seriesNumber has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.frameOfReferenceUid |
Extension: ExtensionImagingSelection_FrameOfReferenceUid | Element ImagingSelection.frameOfReferenceUid is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.frameOfReferenceUid has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.bodySite |
Extension: ExtensionImagingSelection_BodySite | Element ImagingSelection.bodySite is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.bodySite has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.focus |
Extension: ExtensionImagingSelection_Focus | Element ImagingSelection.focus is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.focus has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.instance |
Extension: ExtensionImagingSelection_Instance | Element ImagingSelection.instance is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.instance has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.instance.uid |
Extension: ExtensionImagingSelection_Instance Slice:uid | Element ImagingSelection.instance.uid is part of an existing definition because parent element ImagingSelection.instance requires a cross-version extension.Element ImagingSelection.instance.uid is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.instance.uid has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.instance.number |
Extension: ExtensionImagingSelection_Instance Slice:number | Element ImagingSelection.instance.number is part of an existing definition because parent element ImagingSelection.instance requires a cross-version extension.Element ImagingSelection.instance.number is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.instance.number has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.instance.sopClass |
Extension: ExtensionImagingSelection_Instance Slice:sopClass | Element ImagingSelection.instance.sopClass is part of an existing definition because parent element ImagingSelection.instance requires a cross-version extension.Element ImagingSelection.instance.sopClass is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.instance.sopClass has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.instance.subset |
Extension: ExtensionImagingSelection_Instance Slice:subset | Element ImagingSelection.instance.subset is part of an existing definition because parent element ImagingSelection.instance requires a cross-version extension.Element ImagingSelection.instance.subset is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.instance.subset has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.instance.imageRegion2D |
Extension: ExtensionImagingSelection_Instance Slice:imageRegion2D | Element ImagingSelection.instance.imageRegion2D is part of an existing definition because parent element ImagingSelection.instance requires a cross-version extension.Element ImagingSelection.instance.imageRegion2D is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.instance.imageRegion2D has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.instance.imageRegion2D.regionType |
Extension: ExtensionImagingSelection_Instance_ImageRegion2D Slice:regionType | Element ImagingSelection.instance.imageRegion2D.regionType is part of an existing definition because parent element ImagingSelection.instance.imageRegion2D requires a cross-version extension.Element ImagingSelection.instance.imageRegion2D.regionType is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.instance.imageRegion2D.regionType has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.instance.imageRegion2D.coordinate |
Extension: ExtensionImagingSelection_Instance_ImageRegion2D Slice:coordinate | Element ImagingSelection.instance.imageRegion2D.coordinate is part of an existing definition because parent element ImagingSelection.instance.imageRegion2D requires a cross-version extension.Element ImagingSelection.instance.imageRegion2D.coordinate is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.instance.imageRegion2D.coordinate has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.instance.imageRegion3D |
Extension: ExtensionImagingSelection_Instance Slice:imageRegion3D | Element ImagingSelection.instance.imageRegion3D is part of an existing definition because parent element ImagingSelection.instance requires a cross-version extension.Element ImagingSelection.instance.imageRegion3D is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.instance.imageRegion3D has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.instance.imageRegion3D.regionType |
Extension: ExtensionImagingSelection_Instance_ImageRegion3D Slice:regionType | Element ImagingSelection.instance.imageRegion3D.regionType is part of an existing definition because parent element ImagingSelection.instance.imageRegion3D requires a cross-version extension.Element ImagingSelection.instance.imageRegion3D.regionType is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.instance.imageRegion3D.regionType has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
ImagingSelection.instance.imageRegion3D.coordinate |
Extension: ExtensionImagingSelection_Instance_ImageRegion3D Slice:coordinate | Element ImagingSelection.instance.imageRegion3D.coordinate is part of an existing definition because parent element ImagingSelection.instance.imageRegion3D requires a cross-version extension.Element ImagingSelection.instance.imageRegion3D.coordinate is not mapped to FHIR STU3, since FHIR R5 ImagingSelection is not mapped.Element ImagingSelection.instance.imageRegion3D.coordinate has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |