This page is part of the SMART Health Cards Vaccination and Testing, Release 1 | STU 1 (v0.6.2: STU 1 Ballot 1) based on FHIR R4. . For a full list of available versions, see the Directory of published versions
Summary
Defining URL: | http://hl7.org/fhir/uv/shc-vaccination/ValueSet/qualitative-lab-result-findings |
Version: | 0.6.2 |
Name: | QualitativeLabResultFindings |
Title: | Qualitative lab result findings |
Status: | Active as of 2021-08-13T13:26:56+00:00 |
Definition: | This value set includes codes for identifying laboratory test results. It includes SNOMED CT codes from a value set of COVID-19-related SNOMED CT codes, as well as codes from LOINC answer lists with roughly equivalent meanings. While the source value set is COVID-19-related, these codes should apply to all infectious disease-related qualitative laboratory results. |
Publisher: | HL7 International - Public Health Work Group |
Source Resource: | XML / JSON / Turtle |
References
This value set includes codes based on the following rules:
This value set contains 19 concepts
Expansion based on:
Code | System | Display | Definition |
10828004 | http://snomed.info/sct | Positive | |
125154007 | http://snomed.info/sct | Specimen unsatisfactory for evaluation | |
260373001 | http://snomed.info/sct | Detected | |
260385009 | http://snomed.info/sct | Negative | |
260408008 | http://snomed.info/sct | Weakly positive | |
260415000 | http://snomed.info/sct | Not detected | |
419984006 | http://snomed.info/sct | Inconclusive (qualifier value) | |
42425007 | http://snomed.info/sct | Equivocal | |
720735008 | http://snomed.info/sct | Presumed positive | |
82334004 | http://snomed.info/sct | Indeterminate | |
LA11882-0 | http://loinc.org | Detected | |
LA11883-8 | http://loinc.org | Not detected | |
LA11885-3 | http://loinc.org | Equivocal | |
LA9663-1 | http://loinc.org | Inconclusive | |
LA13548-5 | http://loinc.org | Specimen unsatisfactory for evaluation | |
LA6577-6 | http://loinc.org | Negative | |
LA4259-3 | http://loinc.org | Borderline | |
LA6576-8 | http://loinc.org | Positive | |
LA18996-1 | http://loinc.org | Strong positive |
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
Source | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |