This page is part of the Personal Health Device FHIR IG (v1.0.0: STU 1) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
<Device xmlns="http://hl7.org/fhir">
<id value="phg-ecde3d4e58532d31.000000000000"/>
<meta>
<profile value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhgDevice"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative</b></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource "phg-ecde3d4e58532d31.000000000000" </p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-PhgDevice.html">PhgDevice</a></p></div><p><b>identifier</b>: IEEE 11073 System Identifier: ec-de-3d-4e-58-53-2d-31, Bluetooth MAC address: 3d-4e-58-53-2d-31, Ethernet MAC address: 3d-4e-58-53-2d-35</p><p><b>type</b>: MDC_MOC_VMS_MDS_AHD <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531981)</span></p><h3>Versions</h3><table class="grid"><tr><td>-</td><td><b>Type</b></td><td><b>Value</b></td></tr><tr><td>*</td><td>MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532352)</span></td><td>5.0</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NTPV4: <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532226)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532353)</span></p><p><b>valueCode</b>: Pulse Oximeter certified <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="CodeSystem-ContinuaPHD.html">ContinuaPHD</a>#4)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: certified Upload classes <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532355)</span></p><p><b>valueCode</b>: observation-upload-soap <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="CodeSystem-ContinuaHFS.html">ContinuaHFS</a>#0)</span>, observation-upload-hdata <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="CodeSystem-ContinuaHFS.html">ContinuaHFS</a>#3)</span>, observation-upload-fhir <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="CodeSystem-ContinuaHFS.html">ContinuaHFS</a>#7)</span>, capabilities <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="CodeSystem-ContinuaHFS.html">ContinuaHFS</a>#2)</span>, aps <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="CodeSystem-ContinuaHFS.html">ContinuaHFS</a>#6)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="CodeSystem-ASN1ToHL7.html">ASN1ToHL7</a>#532354.0)</span></p><p><b>valueCode</b>: Device is not regulated <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/R4/v2/0136/index.html">v2 Y/N Indicator</a>#Y)</span></p></blockquote></div>
</text>
<identifier>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="SYSID"/>
</coding>
</type>
<system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/>
<value value="ec-de-3d-4e-58-53-2d-31"/>
</identifier>
<identifier>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="BTMAC"/>
</coding>
</type>
<system value="http://hl7.org/fhir/sid/eui-48/bluetooth"/>
<value value="3d-4e-58-53-2d-31"/>
</identifier>
<identifier>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="ETHMAC"/>
</coding>
</type>
<system value="http://hl7.org/fhir/sid/eui-48/ethernet"/>
<value value="3d-4e-58-53-2d-35"/>
</identifier>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531981"/>
</coding>
<text value="MDC_MOC_VMS_MDS_AHD"/>
</type>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532352"/>
</coding>
<text value="MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"/>
</type>
<value value="5.0"/>
</version>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="68220"/>
</coding>
<text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/>
</type>
<valueCode>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532226"/>
</coding>
<text value="MDC_TIME_SYNC_NTPV4:"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532353"/>
</coding>
<text
value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo"/>
</type>
<valueCode>
<coding>
<system value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"/>
<code value="4"/>
</coding>
</valueCode>
</property>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532355"/>
</coding>
<text
value="MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: certified Upload classes"/>
</type>
<valueCode>
<coding>
<system value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"/>
<code value="0"/>
</coding>
</valueCode>
<valueCode>
<coding>
<system value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"/>
<code value="3"/>
</coding>
</valueCode>
<valueCode>
<coding>
<system value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"/>
<code value="7"/>
</coding>
</valueCode>
<valueCode>
<coding>
<system value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"/>
<code value="2"/>
</coding>
</valueCode>
<valueCode>
<coding>
<system value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"/>
<code value="6"/>
</coding>
</valueCode>
</property>
<property>
<type>
<coding>
<system value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
<code value="532354.0"/>
</coding>
<text value="regulation-status"/>
</type>
<valueCode>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
<code value="Y"/>
</coding>
<text value="Device is not regulated"/>
</valueCode>
</property>
</Device>