This page is part of the Personal Health Device FHIR IG (v1.0.0: STU 1) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
<Device xmlns="http://hl7.org/fhir">
<id value="phd-711000FEFF5F49B0.B0495F001071"/>
<meta>
<profile value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative</b></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource "phd-711000FEFF5F49B0.B0495F001071" </p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-PhdDevice.html">PhdDevice</a></p></div><p><b>identifier</b>: IEEE 11073 System Identifier: 71-10-00-FE-FF-5F-49-B0, Bluetooth MAC address: B0-49-5F-00-10-71</p><p><b>manufacturer</b>: OMRONHEALTHCARE</p><p><b>serialNumber</b>: 20150200002A</p><p><b>modelNumber</b>: HEM-9200T</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#65573)</span></p><h3>Specializations</h3><table class="grid"><tr><td>-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_BP: Blood Pressure Cuff <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#528391)</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531976)</span></p><p><b>value</b>: C.00.7AJ-02</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531975)</span></p><p><b>value</b>: 0000000000000101</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531974)</span></p><p><b>value</b>: 0000000000000100</p></blockquote><h3>Properties</h3><table class="grid"><tr><td>-</td><td><b>Type</b></td><td><b>ValueCode</b></td></tr><tr><td>*</td><td>MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></td><td>MDC_TIME_SYNC_NONE: <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></td></tr></table></div>
</text>
<identifier>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="SYSID"/>
</coding>
</type>
<system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/>
<value value="71-10-00-FE-FF-5F-49-B0"/>
</identifier>
<identifier>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="BTMAC"/>
</coding>
</type>
<system value="http://hl7.org/fhir/sid/eui-48/bluetooth"/>
<value value="B0-49-5F-00-10-71"/>
</identifier>
<manufacturer value="OMRONHEALTHCARE"/>
<serialNumber value="20150200002A"/>
<modelNumber value="HEM-9200T"/>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="65573"/>
</coding>
<text value="MDC_MOC_VMS_MDS_SIMP"/>
</type>
<specialization>
<systemType>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="528391"/>
</coding>
<text value="MDC_DEV_SPEC_PROFILE_BP: Blood Pressure Cuff"/>
</systemType>
<version value="1"/>
</specialization>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531976"/>
</coding>
<text value="MDC_ID_PROD_SPEC_FW: Firmware revision"/>
</type>
<value value="C.00.7AJ-02"/>
</version>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531975"/>
</coding>
<text value="MDC_ID_PROD_SPEC_SW: Software revision"/>
</type>
<value value="0000000000000101"/>
</version>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531974"/>
</coding>
<text value="MDC_ID_PROD_SPEC_HW: Hardware revision"/>
</type>
<value value="0000000000000100"/>
</version>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="68220"/>
</coding>
<text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/>
</type>
<valueCode>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532224"/>
</coding>
<text value="MDC_TIME_SYNC_NONE:"/>
</valueCode>
</property>
</Device>