Name / Type | Working Capacity (where appropriate) |
---|---|
Mixing Vessel | Capacity: 1000 litres |
Receiving Tank | Capacity: 1200 litres |
Blender | Maximum capacity: 1000 litres |
Heated dryer | Power: 3 kW |
Rotating Impeller with 1.5mm screen | Maximum Speed: 5000 RPM |
Process Step (name) | Parameter | Acceptance Criteria |
---|---|---|
Step: 1
|
Parameter - Capacity |
750 litres
|
Step: 1
|
Parameter - Temperature |
150 °C [Cel] (http://unitsofmeasure.org)
|
Step: 1
|
Controls - pH | pH must be in range 6.9 to 7.1 |
Step: 2
|
Parameter - Maximum Temperature |
40 °C [Cel] (http://unitsofmeasure.org)
|
Step: 2
|
Controls - Water Content | Under 2% |
Step: 3
|
Parameter - Rotational Speed |
2500 rpm
|
Step: 3
|
Controls - Particle Size | Under 200 microns |