This page is part of the International Patient Summary Implementation Guide (v0.3.0: STU 1 (FHIR R4) Ballot 1) based on FHIR R4. The current version which supercedes this version is 1.1.0. For a full list of available versions, see the Directory of published versions
SD.8 StructureDefinition-Device-uv-ips
SD.8.1 Formal Views of Profile Content
Description of Profiles, Differentials, and Snapshots.
The official URL for this profile is: http://hl7.org/fhir/uv/ips/StructureDefinition/Device-uv-ips
Published on Wed Feb 14 00:00:00 EST 2018 as a draft by HL7 International.
This profile builds on Device
Summary
Mandatory: 2 elements (2 nested mandatory elements)
Must-Support: 9 elements
Fixed Value: 1 element
Structures
This structure refers to these other structures:
- http://hl7.org/fhir/uv/ips/StructureDefinition/CodeableConcept-uv-ips
- http://hl7.org/fhir/uv/ips/StructureDefinition/Patient-uv-ips
Slices
This structure defines the following Slices:
- The element Device.type is sliced based on the value of value:coding.system
Differential View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | S | 0..* | ||
id | S | 0..1 | id | |
meta | S | 0..1 | Meta | |
identifier | S | 0..* | Identifier | |
type | S | (Slice Definition) | Type of device.
Preferably valued by using SNOMED CT.
The absence of information, or of devices relevant for purpose of this IPS, shall be explicitly stated by using the codes included in the absent-or-unknown-devices-uv-ips value set. Slice: Unordered, Open by value:coding.system Binding: IPS Medical Devices (preferred) | |
absentOrUnknownDevice | S | 0..1 | CodeableConceptIPS | Binding: Absent or Unknown Devices (required) |
coding | S | 1..1 | CodingIPS | |
system | S | 1..1 | uri | Fixed Value: http://hl7.org/fhir/uv/ips/CodeSystem/absent-unknown-uv-ips |
patient | S | 1..1 | Reference(Patient (IPS)) | |
reference | S | 1..1 | string | |
Documentation for this format |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | SI | 0..* | Item used in healthcare | |
id | SΣ | 0..1 | id | Logical id of this artifact |
meta | SΣ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred) Max Binding: AllLanguages | |
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Additional content defined by implementations | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | S | 0..* | Identifier | Instance identifier |
definition | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |
udiCarrier | ΣI | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI |
issuer | 0..1 | uri | UDI Issuing Organization | |
jurisdiction | 0..1 | uri | Regional UDI authority | |
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String |
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String |
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required) | |
status | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required) |
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible) | |
distinctIdentifier | 0..1 | string | The distinct identification string | |
manufacturer | 0..1 | string | Name of device manufacturer | |
manufactureDate | 0..1 | dateTime | Date when the device was made | |
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
lotNumber | 0..1 | string | Lot number of manufacture | |
serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |
deviceName | I | 0..* | BackboneElement | The name of the device as given by the manufacturer |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
name | 1..1 | string | The name of the device | |
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required) | |
modelNumber | 0..1 | string | The model number for the device | |
partNumber | 0..1 | string | The part number of the device | |
type | S | (Slice Definition) | Type of device.
Preferably valued by using SNOMED CT.
The absence of information, or of devices relevant for purpose of this IPS, shall be explicitly stated by using the codes included in the absent-or-unknown-devices-uv-ips value set. Slice: Unordered, Open by value:coding.system Binding: IPS Medical Devices (preferred) | |
absentOrUnknownDevice | SI | 0..1 | CodeableConceptIPS | Concept - reference to a terminology or just text Binding: Absent or Unknown Devices (required) |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
coding | SI | 1..1 | CodingIPS | A reference to a code defined by a terminology system |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
system | SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/ips/CodeSystem/absent-unknown-uv-ips |
version | SΣ | 0..1 | string | Version of the system - if relevant |
code | SΣ | 0..1 | code | Symbol in syntax defined by the system |
display | SΣ | 0..1 | string | Representation defined by the system |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | S | 0..* | Extension | Extension Slice: Unordered, Open by value:url |
translation | SI | 0..* | (Complex) | Language Translation (Localization) URL: http://hl7.org/fhir/StructureDefinition/translation |
value | 0..1 | string | Primitive value for string Max Length: 1048576 | |
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user |
text | Σ | 0..1 | string | Plain text representation of the concept |
specialization | I | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |
version | 0..1 | string | The version of the standard that is used to operate and communicate | |
version | I | 0..* | BackboneElement | The actual design of the device or software version running on the device |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 0..1 | CodeableConcept | The type of the device version | |
component | 0..1 | Identifier | A single component of the device version | |
value | 1..1 | string | The version text | |
property | I | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
valueQuantity | 0..* | Quantity | Property value as a quantity | |
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |
patient | S | 1..1 | Reference(Patient (IPS)) | Patient to whom Device is affixed |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
reference | SΣI | 1..1 | string | Literal reference, Relative, internal or absolute URL |
type | Σ | 0..1 | uri | Type the reference refers to (e.g. "Patient") Binding: ResourceType (extensible) |
identifier | Σ | 0..1 | Identifier | Logical reference, when literal reference is not known |
display | Σ | 0..1 | string | Text alternative for the resource |
owner | 0..1 | Reference(Organization) | Organization responsible for device | |
contact | 0..* | ContactPoint | Details for human/organization for support | |
location | 0..1 | Reference(Location) | Where the device is found | |
url | 0..1 | uri | Network address to contact device | |
note | 0..* | Annotation | Device notes and comments | |
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device |
parent | 0..1 | Reference(Device) | The parent device | |
Documentation for this format |
Downloads: StructureDefinition: (XML, JSON), Schema: XML Schematron