This page is part of the International Patient Summary Implementation Guide (v0.2.0: STU 1 Ballot 2) based on FHIR v3.5.0. The current version which supercedes this version is 1.1.0. For a full list of available versions, see the Directory of published versions
SD.9 StructureDefinition-device-uv-ips
This profile represents the constraints applied to the Device resource by the International Patient Summary (IPS) FHIR Implementation Guide, based on FHIR R4. A device used by or implanted on the patient is described in the patient summary as an instance of a Device resource constrained by this profile.
Conformance resource variables defined here
SD.9.1 Formal Views of Profile Content
Description of Profiles, Differentials, and Snapshots.
The official URL for this profile is: http://hl7.org/fhir/uv/ips/StructureDefinition/device-uv-ips
Published on Wed Feb 14 00:00:00 AEST 2018 as a draft by HL7 International.
This profile builds on Device
Summary
Mandatory: 1 element (2 nested mandatory elements)
Fixed Value: 3 elements
Prohibited: 14 elements
Structures
This structure refers to these other structures:
Slices
This structure defines the following Slices:
- The element Device.type.coding is sliced based on the value of value:Device.type.coding.system
Differential View
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | |||
![]() ![]() ![]() | 0..1 | Identifier | ||
![]() ![]() ![]() ![]() | 0..0 | |||
![]() ![]() ![]() ![]() | 0..1 | CodeableConcept | ||
![]() ![]() ![]() ![]() ![]() | 0..0 | |||
![]() ![]() ![]() ![]() | 0..0 | |||
![]() ![]() ![]() ![]() | 0..1 | string | ||
![]() ![]() ![]() ![]() | 0..0 | |||
![]() ![]() ![]() ![]() | 0..0 | |||
![]() ![]() ![]() | 0..1 | dateTime | ||
![]() ![]() ![]() | 0..1 | dateTime | ||
![]() ![]() ![]() | 0..1 | CodeableConcept | Binding: IPS Medical Devices (preferred) | |
![]() ![]() ![]() ![]() | coding-uv-ips | Slice: Unordered, Open by value:Device.type.coding.system | ||
![]() ![]() ![]() ![]() | 0..* | Coding | Binding: IPS Medical Devices (required) | |
![]() ![]() ![]() ![]() ![]() | 1..1 | uri | Fixed Value: http://hl7.org/fhir/uv/ips/CodeSystem/absent-unknown | |
![]() ![]() ![]() ![]() ![]() | 1..1 | code | ||
![]() ![]() ![]() | 1..1 | Reference(Patient) | ||
![]() ![]() ![]() | 0..0 | |||
![]() ![]() ![]() | 0..0 | |||
![]() ![]() ![]() | 0..0 | |||
![]() ![]() ![]() | 0..0 | |||
![]() ![]() ![]() | 0..0 | |||
![]() ![]() ![]() | 0..0 | |||
![]() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | I | 0..* | Item used in healthcare | |
![]() ![]() ![]() | Σ | 0..1 | id | Logical id of this artifact |
![]() ![]() ![]() | Σ | 0..1 | Meta | Metadata about the resource |
![]() ![]() ![]() | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() | 0..1 | code | Language of the resource content Binding: Common Languages (preferred) | |
![]() ![]() ![]() | 0..1 | Narrative | Text summary of the resource, for human interpretation | |
![]() ![]() ![]() | 0..* | Resource | Contained, inline Resources | |
![]() ![]() ![]() | 0..* | Extension | Additional Content defined by implementations | |
![]() ![]() ![]() | ?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() | 0..1 | Identifier | Instance identifier | |
![]() ![]() ![]() ![]() | 0..1 | string | xml:id (or equivalent in JSON) | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() | Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible) |
![]() ![]() ![]() ![]() ![]() | 0..1 | string | xml:id (or equivalent in JSON) | |
![]() ![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() ![]() | Σ | 0..* | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() ![]() | 0..1 | string | xml:id (or equivalent in JSON) | |
![]() ![]() ![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() ![]() ![]() | Σ | 0..1 | code | Symbol in syntax defined by the system Fixed Value: SNO |
![]() ![]() ![]() ![]() ![]() ![]() | Σ | 0..1 | string | Representation defined by the system Fixed Value: serial number |
![]() ![]() ![]() ![]() | Σ | 0..1 | string | The value that is unique Example General': 123456 |
![]() ![]() ![]() | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |
![]() ![]() ![]() | ΣI | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string |
![]() ![]() ![]() ![]() | 0..1 | string | xml:id (or equivalent in JSON) | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored if unrecognized |
![]() ![]() ![]() ![]() | Σ | 0..1 | string | Mandatory fixed portion of UDI |
![]() ![]() ![]() ![]() | 0..1 | uri | UDI Issuing Organization | |
![]() ![]() ![]() ![]() | 0..1 | uri | Regional UDI authority | |
![]() ![]() ![]() ![]() | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String |
![]() ![]() ![]() ![]() | Σ | 0..1 | string | UDI Human Readable Barcode String |
![]() ![]() ![]() ![]() | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required) | |
![]() ![]() ![]() | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required) |
![]() ![]() ![]() | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible) | |
![]() ![]() ![]() | 0..1 | string | The distinct identification code for a biological product regulated as a device | |
![]() ![]() ![]() | 0..1 | string | Name of device manufacturer | |
![]() ![]() ![]() | 0..1 | dateTime | Date when the device was made | |
![]() ![]() ![]() | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
![]() ![]() ![]() | 0..1 | string | Lot number of manufacture | |
![]() ![]() ![]() | 0..1 | string | Serial number assigned by the manufacturer | |
![]() ![]() ![]() | I | 0..* | BackboneElement | The name of the device as given by the manufacturer |
![]() ![]() ![]() ![]() | 0..1 | string | xml:id (or equivalent in JSON) | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored if unrecognized |
![]() ![]() ![]() ![]() | 1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required) | |
![]() ![]() ![]() | 0..1 | string | The model number for the device | |
![]() ![]() ![]() | 0..1 | string | The part number of the device | |
![]() ![]() ![]() | 0..1 | CodeableConcept | The kind or type of device Binding: IPS Medical Devices (preferred) | |
![]() ![]() ![]() ![]() | 0..1 | string | xml:id (or equivalent in JSON) | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() | Σ | coding-uv-ips | Code defined by a terminology system Slice: Unordered, Open by value:Device.type.coding.system | |
![]() ![]() ![]() ![]() | Σ | 0..* | Coding | Code defined by a terminology system Binding: IPS Medical Devices (required) |
![]() ![]() ![]() ![]() ![]() | 0..1 | string | xml:id (or equivalent in JSON) | |
![]() ![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
![]() ![]() ![]() ![]() ![]() | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/ips/CodeSystem/absent-unknown |
![]() ![]() ![]() ![]() ![]() | Σ | 0..1 | string | Version of the system - if relevant |
![]() ![]() ![]() ![]() ![]() | Σ | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() ![]() ![]() | Σ | 0..1 | string | Representation defined by the system |
![]() ![]() ![]() ![]() ![]() | Σ | 0..1 | boolean | If this coding was chosen directly by the user |
![]() ![]() ![]() ![]() | Σ | 0..1 | string | Plain text representation of the concept |
![]() ![]() ![]() | I | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication |
![]() ![]() ![]() ![]() | 0..1 | string | xml:id (or equivalent in JSON) | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored if unrecognized |
![]() ![]() ![]() ![]() | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |
![]() ![]() ![]() ![]() | 0..1 | string | The version of the standard that is used to operate and communicate | |
![]() ![]() ![]() | I | 0..* | BackboneElement | The actual design of the device or software version running on the device |
![]() ![]() ![]() ![]() | 0..1 | string | xml:id (or equivalent in JSON) | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored if unrecognized |
![]() ![]() ![]() ![]() | 0..1 | CodeableConcept | The type of the device version | |
![]() ![]() ![]() ![]() | 0..1 | Identifier | A single component of the device version | |
![]() ![]() ![]() ![]() | 1..1 | string | The version text | |
![]() ![]() ![]() | I | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties |
![]() ![]() ![]() ![]() | 0..1 | string | xml:id (or equivalent in JSON) | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored if unrecognized |
![]() ![]() ![]() ![]() | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
![]() ![]() ![]() ![]() | 0..* | Quantity | Property value as a quantity | |
![]() ![]() ![]() ![]() | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |
![]() ![]() ![]() | 1..1 | Reference(Patient) | Patient to whom Device is affixed | |
![]() ![]() ![]() | 0..1 | Reference(Device) | The parent device | |
![]() |
Downloads: StructureDefinition: (XML, JSON), Schema: XML Schematron