This page is part of the International Patient Summary Implementation Guide (v0.1.0: STU 1 Ballot 1) based on FHIR R3. The current version which supercedes this version is 1.1.0. For a full list of available versions, see the Directory of published versions
Definitions for the StructureDefinition-range-uv-ips Profile.
Range | |
Definition | A set of ordered Quantities defined by a low and high limit. |
Control | 0..* This element is affected by the following invariants: ele-1 |
Comments | The stated low and high value are assumed to have arbitrarily high precision when it comes to determining which values are in the range. I.e. 1.99 is not in the range 2 -> 3. |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() | (children().count() > id.count())) rng-2: If present, low SHALL have a lower value than high (: low.empty() or high.empty() or (low <= high)) |
Range.id | |
Definition | unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
Range.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Range.low | |
Definition | The low limit. The boundary is inclusive. |
Control | 0..1 This element is affected by the following invariants: rng-2 |
Type | Quantity(SimpleQuantity) |
Comments | If the low element is missing, the low boundary is not known. |
Range.low.id | |
Definition | unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
Range.low.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Range.low.value | |
Definition | The value of the measured amount. The value includes an implicit precision in the presentation of the value. |
Control | 0..1 |
Type | decimal |
Requirements | Precision is handled implicitly in almost all cases of measurement. |
Comments | The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books). |
Range.low.comparator | |
Definition | Not allowed to be used in this context |
Control | 0..0 |
Binding | How the Quantity should be understood and represented. The codes SHALL be taken from QuantityComparator |
Type | code |
Is Modifier | true |
Requirements | Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology. |
Comments | This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value. |
Meaning if Missing | If there is no comparator, then there is no modification of the value |
Range.low.unit | |
Definition | A human-readable form of the unit. |
Control | 0..1 |
Type | string |
Requirements | There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms. |
Range.low.system | |
Definition | The identification of the system that provides the coded form of the unit. |
Control | 1..1 This element is affected by the following invariants: qty-3 |
Type | uri |
Requirements | Need to know the system that defines the coded form of the unit. |
Fixed Value | http://unitsofmeasure.org |
Range.low.code | |
Definition | A computer processable form of the unit in some unit representation system. |
Control | 0..1 |
Type | code |
Requirements | Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest. |
Comments | The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system. |
Range.high | |
Definition | The high limit. The boundary is inclusive. |
Control | 0..1 This element is affected by the following invariants: rng-2 |
Type | Quantity(SimpleQuantity) |
Comments | If the high element is missing, the high boundary is not known. |