"resourceType" : "ValueSet",
"id" : "NumericResultIntVS",
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ValueSet NumericResultIntVS</b></p><a name=\"NumericResultIntVS\"> </a><a name=\"hcNumericResultIntVS\"> </a><a name=\"NumericResultIntVS-en-US\"> </a><ul><li>Include these codes as defined in <a href=\"http://terminology.hl7.org/6.1.0/CodeSystem-v3-ObservationInterpretation.html\"><code>http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td><a href=\"http://terminology.hl7.org/6.1.0/CodeSystem-v3-ObservationInterpretation.html#v3-ObservationInterpretation-A\">A</a></td><td>Abnormal</td><td>The result or observation value is outside the reference range or expected norm (as defined for the respective test procedure).<br/><br/>\\[Note: Typically applies to non-numeric results.\\]</td></tr><tr><td><a href=\"http://terminology.hl7.org/6.1.0/CodeSystem-v3-ObservationInterpretation.html#v3-ObservationInterpretation-H\">H</a></td><td>Higher Than Normal</td><td>The result for a quantitative observation is above the upper limit of the reference range (as defined for the respective test procedure).<br/><br/>Synonym: Above high normal</td></tr><tr><td><a href=\"http://terminology.hl7.org/6.1.0/CodeSystem-v3-ObservationInterpretation.html#v3-ObservationInterpretation-L\">L</a></td><td>Lower Than Normal</td><td>The result for a quantitative observation is below the lower limit of the reference range (as defined for the respective test procedure).<br/><br/>Synonym: Below low normal</td></tr><tr><td><a href=\"http://terminology.hl7.org/6.1.0/CodeSystem-v3-ObservationInterpretation.html#v3-ObservationInterpretation-HH\">HH</a></td><td>Panic High</td><td>The result for a quantitative observation is above a reference level at which immediate action should be considered for patient safety (as defined for the respective test procedure).<br/><br/>Synonym: Above upper panic limits.</td></tr><tr><td><a href=\"http://terminology.hl7.org/6.1.0/CodeSystem-v3-ObservationInterpretation.html#v3-ObservationInterpretation-LL\">LL</a></td><td>Panic Low</td><td>The result for a quantitative observation is below a reference level at which immediate action should be considered for patient safety (as defined for the respective test procedure).<br/><br/>Synonym: Below lower panic limits.</td></tr><tr><td><a href=\"http://terminology.hl7.org/6.1.0/CodeSystem-v3-ObservationInterpretation.html#v3-ObservationInterpretation-N\">N</a></td><td>Normal</td><td>The result or observation value is within the reference range or expected norm (as defined for the respective test procedure).<br/><br/>\\[Note: Applies to numeric or non-numeric results.\\]</td></tr></table></li></ul></div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "cic"
}
],
"url" : "http://hl7.org/fhir/uv/cardx-htn-mng/ValueSet/NumericResultIntVS",
"version" : "1.0.0",
"name" : "NumericResultInterpretationNom",
"title" : "Numeric Result Interpretation value set",
"status" : "draft",
"experimental" : false,
"date" : "2024-12-12T14:41:15+00:00",
"publisher" : "HL7 International / Clinical Interoperability Council",
"contact" : [
{
"name" : "HL7 International / Clinical Interoperability Council",
"telecom" : [
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/cic"
},
{
"system" : "email",
"value" : "ciclist@lists.hl7.org"
}
]
}
],
"description" : "The HL7 V3:ObservationInterpretation code set (OID: 2.16.840.1.113883.5.83) that describes interpretations associated with a measured value.",
"jurisdiction" : [
{
"coding" : [
{
"system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code" : "001",
"display" : "World"
}
]
}
],
"compose" : {
"include" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
"concept" : [
{
"code" : "A",
"display" : "Abnormal"
},
{
"code" : "H",
"display" : "Higher Than Normal"
},
{
"code" : "L",
"display" : "Lower Than Normal"
},
{
"code" : "HH",
"display" : "Panic High"
},
{
"code" : "LL",
"display" : "Panic Low"
},
{
"code" : "N",
"display" : "Normal"
}
]
}
]
}
}